Albbshv Cable 3X50+1X25mm. Gost-22483-2012 Nominal Alternating Voltage-0.66/1Kv, Stake Of Core-3+1, Section Size 50+16Mm2, Nominal Frequency 50Hz, Inductive Resistance 0.0662Om/Km, Active Resistance 0.64 Ohms, Current Load In The Air-126/142 A, On The Ground-143/165 A, Korotkoye Korotky Classes 3.38Ka, Mac. Voltage 220V –31.00Kw, In The Air Voltage 380V - 82.00Kw, In The Earth Voltage 380V –94.00Kw, Gost - 31966–2012. The Unloading Of The Material Is Carried Out At The Customer Warehouse At The Expense Of The Supplier., Vru -11 Uhl4 Gost51321-2007 Rated Voltage - 380/220V, Nominal Current - Up To 250 A, Frequency - 50 Hz, Climatic Performance - Uhl4, Degree Of Protection - Ir31, Polown, Automatic Circuit Breakers, Tire Assemblies, Grounding/Zero -Navy, Unloading Of The Material To The Customer’S Storage Out Of The Warehouse Due Supplier., Schuino External Lighting Control Panel With A Built -In Photocell Gost Voltage - 220V, Load Current - 63 A, Photocell - Integrated, Operation At The Light Level - 10-30 Lux, Degree Of Protection - Not Lower Than Ir54, Climatic Performance - Uhl1, Installation - Mounting, Equipment - Automatar, Terminals, Dialects, Din -Rack. The Unloading Of The Material Is Made To The Customer’S Warehouse At The Expense Of The Supplier., Lamp Led Wall-Flowing 600X600mm 48 Watts. 6500K. Gost -5089 Power 48 W Type Lamp Type - Led Case Material - Steel Degree Of Protection - Ip40 Nom. Voltage - 180-265V Bull Color - White Length - 600 Mm Width - 600 Mm Height/Depth - 19 Mm. Light Temperature - 6500 To Light Flow - 2700 Lm Reinforcement Material - Plastic. Unloading Of Materials Is Carried Out At The Customer Warehouse At The Expense Of The Supplier, Cable End Cloth 3 Kwp 10Kv (70-120) (B) Kw Gost-13781.0-86 Type Of Coupling-Terminal, Installation Technology –Termoisy, Operating Voltage-Up To 10Kv, Section Of The Veins-70/120 Mm2, Isolation Of The Cable-Affected Cable, Type Of Installation-In Cable Channels And Soils, Type Of Type Cable -With Armor/Without Armor, Equipment -With Bolted Joints, Operation Temperature --50+50̊ C, Brand Of Mounted Cables -Avbbshv, Asb -95. The Unloading Of The Material Is Carried Out At The Customer Warehouse At The Expense Of The Supplier., Albbshv Cable 3X25+1X16mm. Gost-22483-2012 Nominal Alternating Voltage-0.66/1Kv, Stake Of Core-3+1, Section Size 25+16Mm2, Nominal Frequency 50Hz, Inductive Resistance 0.0662Om/Km, Active Resistance Of 1.28 Ohms/Km, Current Load In The Air-87/98 A. On The Ground-102/118 A. Korotkoy Korol Classes 1.81Ka, Mac. Voltage 220V –22.00Kw, Class Security O1.8.2.5.4 Gost - 31966–2012. The Unloading Of The Material Is Made To The Customer’S Warehouse At The Expense Of The Supplier. ”, Connecting Coupling For Cable 4 Stp 1X70/120 (B) 10Kv (Kwp) Gost-13781.0-86 Type Of Coupling-Connecting, Installation Technology –Term-Operating Voltage-Up To 1Kv, Section Of The Cores-70/120 Mm2, Isolation Of The Packed Paper, Type Of Installation-In Cable Channels And Cable Channels And Cable Channels And Cable Channels And Cable Channels And Cable Channels And Cable Channels And Cable Channels And Cable Channels And Cable Channels And Cable Channels And Cable Channels And Cable Channels Soils, The Type Of Cable -With Armor/Without Armor, Equipment -With Bolted Joints, Operation Temperature --50+50̊ C, Brand Of Mounted Cables -Aubbshv, Asb -95. The Unloading Of The Material Is Made To The Customer’S Warehouse At The Expense Of The Supplier.