Bids Are Invited For Hiring A Company Specialized In Services For The Leasing Of Oxygen Concentrators, Equipment For Home Ventilatory Care (Bipap, Cpap And Fans), Tracheal Secretion Vacuum Cleaner And Medicinal Oxygen Recharges To Care For Patients In The Municipal Health Network.
Bids Are Invited For Hiring A Company Specialized In Services For The Leasing Of Oxygen Concentrators, Equipment For Home Ventilatory Care (Bipap, Cpap And Fans), Tracheal Secretion Vacuum Cleaner And Medicinal Oxygen Recharges To Care For Patients In The Municipal Health Network.
Lot 1 - Medicinal Oxygen Recharge Of 3 To 10M3 Backup Cylinders Delivered To Cylinders With Regulators And Flows, Lot 1 - Monthly Rental Of An Electric Oxygen Concentrator Up To 5Lpm With 3 To 10 M3 Backup Cylinder; Included, Regulator, Flux And Disposable (Cannula Or Adult Or Pediatric Mask, Humidifier And Extension Glass) With Exchange Every 6 Months And The Cannula With Exchange Every 3 Months; Voltage 110 Or 220V. Present Certificate Of Registration At Anvisa Equipment And Accessories, Lot 1 - Monthly Lease Of Electric Oxygen Concentrator Up To 10Lpm With 3 To 10 M3 Backup Cylinder Included, Fluxometro And Disposable (Silicone Cannula Or Adult Or Pediatric Mask, Lot 1 - Bipap Location Without Internal Battery With Humidifier, Nobreak And Disposable - Location. Bipap-Non-Invasive Mechanical Ventilation Device Having The Following Modes: Cpap, S, St, T, Pac And Volume Warranty. * Ramp: Automatic Or With Starting 0-5 * Pressure Operation Strip To 30 Cmh2o. Heated And Air Filter Humidifier * Energy Input: 100-240V (Bivolt). Pediatric As Needed By The Patient, The Circuits, Masks Every 6 Months And Filters Every 3 Months Include Synoidal No-Break, Compatible With Bipap Device, With Power At Least 1400 Va, With Autonomy At Least 4 Hours. The Data Physically (Printed) And/Or Electronicly By Emails The Follow -Up And Monitoring Reports Of Each Cpap And Bipap User. Lot 1 - Bipap Rental Complex With Internal Battery With Humidifier, Nobreak And Disposable. Psv; Ipap: 4 To 40 Cmh2o; Peep: 4 To 25 Cmh2o; Cpap 4 To 20 Cmh2o; Current Volume: 100Ml; Sineidal Power At Least 1400 Va, With Autonomy Of 4 Hours. In The Patient Adaptation, 01 Nasal/ Facial Mask (P, M Or G) Or Pediatric As Needed Or Tracheostomy Adapting Circuit If Necessary, Trachea Change Every 6 Months And Filters Every 3 Months. Equipment And Accessories Anvisa Registration Certificate. ** It Should Include Sd Data Card Every 3 Or 6 Months, Providing Physically (Printed) And/Or Electronic Data By Email Reporting And Program Monitoring Of Each Cpap And Bipap User.
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.