Correspondence Of Goods To The Interstate Standards Of Gost 26035-83 The Meter Of Single-Phase Electric Energy Of Alternating Current Electronic- Mercury 206 Is Designed For Multi-Tariff Accounting Of Active And Reactive Electrical Energy And Power, As Well As Measuring The Parameters Of The Electric Network In Two-Wire Networks Of Alternating Current With The Subsequent Storage Of Events And The Transfer Of Information To The Centers Of The Collection Of Systems Of Askue Systems. The Counters Are Designed For Operation Inside Closed Rooms And Can Be Used In Places That Have Additional Protection Against Environmental Influence (Installed In The Room, In The Closet, In The Shield). Active / Complete Power Consumption By The Meter Voltage With A Rated Voltage, Vt / B*A- 2.5 / 7, Full Power Consumed By Each Current Circuit, No More, In*A -0.5, Additional Active / Complete Power Consumption By The Meter Voltage At Nominal Voltage, In The Presence Of The Plc Interface, Wt / V*A-1.4, The Amount Of Tariffs-4, Tariffs, 4 The Safety Of The Data During Power Breaks, At Least Years-10, Intercetress Interval, Years- 16, Warranty Period Of Operation, 3 Years Old, Is The Development Of A Refusal, At Least, H-200,000, Operating Temperature Range, ° C-45 To +70, Mass, No More, Kg- 0.6, Dimensions (Dhshhv), Mm- 154*105*72