Tip Of Aluminum Cable Tone 35 Cable Aluminum Tip T 35-10-8 Ethars Aluminum Tip 35-10-8 Compound Aluminum Fixed By Pressure Testing Is Designed To Connect Cables With Aluminum Veins With A Section Of 35 Mm2. Aluminum Tips For Crimping Are Used For Cables With A Voltage Of Up To 10 Square Meters. • Size D1: 148 • Size D2: 14 • Size L: 71 • Guarantee- 1 Year. , Certificate And Passport, Test Protocol. Delivery. Unloading Of Goods To The Facility And The Delivery Of Material In The Presence (Supplier) Of The Representative Must, Tip Aluminum Cable T 120 Cable Aluminum Tip T 120-12-14 Ethars Aluminum Tip 35-10-8 Compound Aluminum Fixed By Pressure Testing Is Designed To Connect Cables With Aluminum Veins With A Section Of 35 Mm2. Aluminum Tips For Crimping Are Used For Cables With A Voltage Of Up To 10 Square Meters. • Size D1: 14.5 • Size D2: 22 • Size L: 100 • Guarantee- 1 Year. , Certificate And Passport, Test Protocol. Delivery. Unloading Of Goods To The Facility And The Delivery Of Material In The Presence (Supplier) Of The Representative Must, Tip Of Aluminum Cable Tone 50 Cable Aluminum Tip At 50 Aluminum Tip 50 Connective Aluminum Fixed By Crimping Is Designed To Connect Cables With Aluminum Cores With A Cross Section Of 50 Mm2. Aluminum Tips For Crimping Are Used For Cables With A Voltage Of Up To 10 Square Meters. • Guarantee- 1 Year. , Certificate And Passport, Test Protocol. Delivery. Unloading Of Goods To The Facility And The Delivery Of Material In The Presence (Supplier) Of The Representative Must, Tip Of Aluminum Cable Tu 25 Cable Aluminum Tip At 25 The Aluminum Tip 25 Connecting Aluminum Fixed By Crimping Is Designed To Connect Cables With Aluminum Cores With A Section Of 25 Mm2. Aluminum Tips For Crimping Are Used For Cables With A Voltage Of Up To 10 Square Meters. • Guarantee- 1 Year. , Certificate And Passport, Test Protocol. Delivery. Unloading Of Goods To The Facility And The Delivery Of Material In The Presence (Supplier) Of The Representative Must, Tip Of Aluminum Cable Tu 16 Cable Aluminum Tip At 25 The Aluminum Tip 25 Connecting Aluminum Fixed By Crimping Is Designed To Connect Cables With Aluminum Cores With A Section Of 25 Mm2. Aluminum Tips For Crimping Are Used For Cables With A Voltage Of Up To 10 Square Meters. • Guarantee- 1 Year. , Certificate And Passport, Test Protocol. Delivery. Unloading Of Goods To The Facility And The Delivery Of Material In The Presence (Supplier) Of The Representative Must, Gilsa Aluminum Cable Ha 95 Cable Aluminum Gaulus 95 Zeetarus Type Of Product: Ha 95 Type Of Product: Slee Of Aluminum Voltage: Up To 10 Kv Nominal Section, Mm2: 95 Size D1: 14 Size D2: 22 Size L: 100 Method Method: Id A Cost Cover: No Climatic Expection: Uhl 3 Is Made According To: Gost 23469.2-79 Material Code: 3444987 Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of Material In The Presence (Deliveryer) Of The Representative Must, Gilsa Aluminum Cable Ha 35 Abel Aluminum Gars 35-8 Zetarar The Aluminum Ga Lip Of 120-14 Connective Aluminum Fixed By Crimping Is Designed To Connect The Wires And Cables With Aluminum Cores With A Section Of 35 Mm2. Aluminum Sleeves For Crimping Are Used For Cables With A Voltage Of Up To 10 Square Meters. • Size D1: 8 • Size D2: 14 • Size L: 71 • Guarantee- 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Gilsa Aluminum Cable Ha 16 Cable Aluminum Sleeve 16 Zeatarus The Aluminum Gilllac Heallia Coluding Aluminum Fixed By Crimping Is Designed To Connect The Wires And Cables With Aluminum Veins With A Section Of 16 Mm2. Aluminum Sleeves For Crimping Are Used For Cables With A Voltage Of Up To 10 Square Meters. • Guarantee- 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Gilsa Aluminum Cable Ha 50 Cable Aluminum Gar Gars 50 Zetarur The Aluminum Gilsic Gilse 50 Connective Aluminum Fixed By Crimping Is Designed To Connect The Wires And Cables With Aluminum Cores With A Cross Section Of 50 Mm2. Aluminum Sleeves For Crimping Are Used For Cables With A Voltage Of Up To 10 Square Meters. • Guarantee- 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Gilsa Aluminum Cable Ha 25 Cable Aluminum Gar Gar 25 Zetarur The Aluminum Ga Sleeve 25 Connective Aluminum Fixed By Crimping Is Designed To Connect The Wires And Cables With Aluminum Cores With A Section Of 25 Mm2. Aluminum Sleeves For Crimping Are Used For Cables With A Voltage Of Up To 10 Square Meters. • Guarantee- 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Automat 1P Va 47-29 16 A Iec Circuit Breaker Val47-29 1P In 16A The Va47-29 Circuit Breakers Are Designed To Protect The Distribution And Group Circuits That Have A Different Load:-Electrical Appliances, Lighting-Switches With Characteristics B-Engines With Small Starting Currents (Compressor, Fan)-Switches With Characteristics C,-Engines With Large Start-Up Currents (Lifting Mechanisms, Pumps)-Switches With A Characteristic Of D. Va47-29 Circuit Breakers Are Recommended For Use In Introductory-Distribution Devices For Residential And Public Buildings. Nomin Current, And 16.0 The Number Of Poles 1 Nomin Pulsed Withstanding Voltage, Kv 4 The Description Characteristic Is The Current Curve In Type Of Voltage Of Change./Constant. (Ac/Dc Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Automat 3P Va 47-29 50 A Iec Automatic Circuit Breaker 3 Pole Va47-29 3P In 50 D The Va47-29 Circuit Breakers Are Designed To Protect The Distribution And Group Circuits That Have A Different Load:-Electrical Appliances, Lighting-Switches With Characteristics B-Engines With Small Starting Currents (Compressor, Fan)-Switches With Characteristics C,-Engines With Large Start-Up Currents (Lifting Mechanisms, Pumps)-Switches With A Characteristic Of D. Va47-29 Circuit Breakers Are Recommended For Use In Introductory-Distribution Devices For Residential And Public Buildings. Nomin Current, And 50 The Number Of Poles 3 Nomin Pulsed Withstanding Voltage, Kv 4 Driving Characteristics - Curve Dock D Type Of Voltage Of Change./Constant. (Ac/Dc Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Automat 3P Va 47-29 40 A Iec Automatic Circuit Breaker 3 Pole V. The Va47-29 Circuit Breakers Are Designed To Protect The Distribution And Group Circuits That Have A Different Load:-Electrical Appliances, Lighting-Switches With Characteristics B-Engines With Small Starting Currents (Compressor, Fan)-Switches With Characteristics C,-Engines With Large Start-Up Currents (Lifting Mechanisms, Pumps)-Switches With A Characteristic Of D. Va47-29 Circuit Breakers Are Recommended For Use In Introductory-Distribution Devices For Residential And Public Buildings. Nomin Current, And 40 The Number Of Poles 3 Nomin Pulsed Withstanding Voltage, Kv 4 Driving Characteristics - Curve Dock D Type Of Voltage Of Change./Constant. (Ac/Dc Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Automat 1P Va 47-29 10 A Iec Circuit Breaker Val47-29 1P In 10A The Va47-29 Circuit Breakers Are Designed To Protect The Distribution And Group Circuits That Have A Different Load:-Electrical Appliances, Lighting-Switches With Characteristics B-Engines With Small Starting Currents (Compressor, Fan)-Switches With Characteristics C,-Engines With Large Start-Up Currents (Lifting Mechanisms, Pumps)-Switches With A Characteristic Of D. Va47-29 Circuit Breakers Are Recommended For Use In Introductory-Distribution Devices For Residential And Public Buildings. Nomin Current, And 10.0 The Number Of Poles 1 Nomin Pulsed Withstanding Voltage, Kv 4 The Description Characteristic Is The Current Curve In Type Of Voltage Of Change./Constant. (Ac/Dc Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Automat 1P Va 47-29 20 A Iec Circuit Breaker Val47-29 1P In 20A The Va47-29 Circuit Breakers Are Designed To Protect The Distribution And Group Circuits That Have A Different Load:-Electrical Appliances, Lighting-Switches With Characteristics B-Engines With Small Starting Currents (Compressor, Fan)-Switches With Characteristics C,-Engines With Large Start-Up Currents (Lifting Mechanisms, Pumps)-Switches With A Characteristic Of D. Va47-29 Circuit Breakers Are Recommended For Use In Introductory-Distribution Devices For Residential And Public Buildings. Nomin Current, And 20.0 The Number Of Poles 1 Nomin Pulsed Withstanding Voltage, Kv 4 The Description Characteristic Is The Current Curve In Type Of Voltage Of Change./Constant. (Ac/Dc Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Automat 1P Va 47-29 32 A Iek, Automat 1P Va 47-29 50 A Iec Circuit Breaker Val47-29 1P In 50A The Va47-29 Circuit Breakers Are Designed To Protect The Distribution And Group Circuits That Have A Different Load:-Electrical Appliances, Lighting-Switches With Characteristics B-Engines With Small Starting Currents (Compressor, Fan)-Switches With Characteristics C,-Engines With Large Start-Up Currents (Lifting Mechanisms, Pumps)-Switches With A Characteristic Of D. Va47-29 Circuit Breakers Are Recommended For Use In Introductory-Distribution Devices For Residential And Public Buildings. Nomin Current, And 20.0 The Number Of Poles 1 Nomin Pulsed Withstanding Voltage, Kv 4 The Description Characteristic Is The Current Curve In Type Of Voltage Of Change./Constant. (Ac/Dc Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Automat 1P Va 47-100 100A 10A Characterization C Iec Automatic Circuit Breaker 3 Pole Va47-29 3P In 100 D The Va47-29 Circuit Breakers Are Designed To Protect The Distribution And Group Circuits That Have A Different Load:-Electrical Appliances, Lighting-Switches With Characteristics B-Engines With Small Starting Currents (Compressor, Fan)-Switches With Characteristics C,-Engines With Large Start-Up Currents (Lifting Mechanisms, Pumps)-Switches With A Characteristic Of D. Va47-29 Circuit Breakers Are Recommended For Use In Introductory-Distribution Devices For Residential And Public Buildings. Nomin Current, And 100 The Number Of Poles 3 Nomin Pulsed Withstanding Voltage, Kv 4 Driving Characteristics - Curve Dock D Type Of Voltage Of Change./Constant. (Ac/Dc Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Automat 3P Va 47-29 16 A Iec Circuit Breaker Val47-29 3P In 16A The Va47-29 Circuit Breakers Are Designed To Protect The Distribution And Group Circuits That Have A Different Load:-Electrical Appliances, Lighting-Switches With Characteristics B-Engines With Small Starting Currents (Compressor, Fan)-Switches With Characteristics C,-Engines With Large Start-Up Currents (Lifting Mechanisms, Pumps)-Switches With A Characteristic Of D. Va47-29 Circuit Breakers Are Recommended For Use In Introductory-Distribution Devices For Residential And Public Buildings. Nomin Current, And 16.0 The Number Of Poles 3 Nomin Pulsed Withstanding Voltage, Kv 4 The Description Characteristic Is The Current Curve In Type Of Voltage Of Change./Constant. (Ac/Dc Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory., Automat 3P Va 47-29 63 A Iec Circuit Breaker Val47-29 3P In 63A The Va47-29 Circuit Breakers Are Designed To Protect The Distribution And Group Circuits That Have A Different Load:-Electrical Appliances, Lighting-Switches With Characteristics B-Engines With Small Starting Currents (Compressor, Fan)-Switches With Characteristics C,-Engines With Large Start-Up Currents (Lifting Mechanisms, Pumps)-Switches With A Characteristic Of D. Va47-29 Circuit Breakers Are Recommended For Use In Introductory-Distribution Devices For Residential And Public Buildings. Nomin Current, And 63.0 The Number Of Poles 3 Nomin Pulsed Withstanding Voltage, Kv 4 The Description Characteristic Is The Current Curve In Type Of Voltage Of Change./Constant. (Ac/Dc Warranty Is 1 Year. , Certificate And Passport, Test Protocol. Delivery Of Goods To The Facility And The Delivery Of The Material In The Presence (Deliveryer) Of The Representative Is Mandatory.