Quotation Are Invited For Condition Assessment Of Unfired Pressure Vessels

Tender Detail

99030778
2332501715
Self-Funded
Quotation Are Invited For Condition Assessment Of Unfired Pressure Vessels
NCB
Asia
Arab World1,Gulf Cooperation Council, GCC,Middle East,Middle East and North Africa, MENA
14-07-2025

Work Detail

Quotation are invited for Condition Assessment of Unfired Pressure Vessels at P1 S & D Dewa, Jabal Ali Power Station SCOPE OF WORK (SOW) FOR INSPECTION OF UNFIRED PRESSURE VESSELS AS PERAPI 5101. INTRODUCTION THIS SCOPE OF WORK (SOW) DEFINES THE REQ UIREMENTS FORTHE INSPECTION OF UNFIRED PRESSURE VESSELS IN ACCORDANCE WITH API 510,PRESSURE VESSEL INSPECTION CODE: IN-SERVICE INSP ECTION, RATING, REPAIR,AND ALTERATION. THE OBJECTIVE OF THIS INSPECTION IS TO ENSURE THEINTEGRITY, SAFETY, AND COMPLIANCE OF PRESSU RE VESSELS WITH APPLICABLEINDUSTRY STANDARDS, REGULATORY REQUIREMENTS, AND CLIENT SPECIFICATIONS.2. SCOPE OF WORK THE INSPECTION SHA LL INCLUDE BUT NOT BE LIMITED TO THEFOLLOWING ACTIVITIES:2.1 PRE-INSPECTION ACTIVITIES:·#REVIEW OF APPLICABLE CODES, STANDARDS, AND REGULATIONS (API 510, ASMESECTION VIII, NBIC, JURISDICTIONAL REQUIREMENTS).·#REVIEW OF VESSEL DESIGN, OPERATIONAL HISTORY, PREVIOUS INSPECTIONRECORDS, AND MAINTENANCE REPORTS.·#DEVELOPMENT OF AN INSPECTION PLAN INCLUDING METHODS, SCOPE, ANDFREQUENCY IN ACCORDANCE WITH API 510.·#IDENTIFICATION OF INSPECTION LOCATIONS, PRESSURE RATINGS, MATERIALS,AND SERVICE CONDITIONS.2.2 ON-SITE INSPECTION ACT IVITIES:·#EXTERNAL VISUAL INSPECTION:O#CHECK FOR CORROSION, CRACKS, LEAKS, MECHANICAL DAMAGE, AND EXTERNALATTACHMENTS.O#INSPECT INSU LATION AND COATINGS FOR DETERIORATION.O#EVALUATE PRESSURE RELIEF DEVICES FOR PROPER FUNCTIONING ANDCOMPLIANCE.·#INTERNAL VISUAL INSP ECTION (IF APPLICABLE):O#ASSESS INTERNAL SURFACES FOR CORROSION, EROSION, PITTING, AND OTHERDEGRADATION MECHANISMS.O#CHECK FOR DEPOS ITS, SCALING, AND FOREIGN MATERIAL.O#VERIFY THE CONDITION OF WELDS, JOINTS, AND STRUCTURAL SUPPORTS.·#NON-DESTRUCTIVE EXAMINATION (N DE):O#ULTRASONIC THICKNESS MEASUREMENT (UTM) TO ASSESS MATERIAL THINNING.O#MAGNETIC PARTICLE TESTING (MT) AND DYE PENETRANT TESTING (PT) FORCRACK DETECTION.O#RADIOGRAPHIC TESTING (RT) IF REQUIRED FOR WELD INTEGRITY ASSESSMENT.O#EDDY CURRENT TESTING (ECT) OR PHASED ARRAY ULTRASONIC TESTING (PAUT)WHERE APPLICABLE.·#PRESSURE TESTING:O#PERFORM HYDROSTATIC OR PNEUMATIC TESTING AS PER API 510 AND AS MEREQUIREMENTS (IF REQUIRED).O#LEAK DETECTION USING APPROPRIATE METHODS SUCH AS BUBBLE TESTING ORACOUSTIC EMISSION.·#FITNESS-FOR-SER VICE (FFS) ASSESSMENT:O#EVALUATE REMAINING LIFE CALCULATIONS AND MINIMUM ALLOWABLE THICKNESS.O#RECOMMEND CORRECTIVE ACTIONS BASED ON INSPECTION FINDINGS.O#PROVIDE FFS CERTIFICATE FOR 10 YEARS2.3 POST-INSPECTION ACTIVITIES:·#DOCUMENTATION AND REPORTING:O#PREPARE AN INSPECTION REPORT DETAILING FINDINGS, TEST RESULTS, ANDPHOTOGRAPHS.O#PROVIDE RECOMMENDATIONS FOR REPAIRS, MAINTENANCE, AND FUTUREIN SPECTION INTERVALS.O#SUBMIT COMPLIANCE REPORTS IN ACCORDANCE WITH REGULATORY AND CLIENTREQUIREMENTS.·#COORDINATION FOR REPAIR AND RE -INSPECTION:O#PROVIDE GUIDANCE ON REQUIRED REPAIRS AS PER API 510 AND ASME PCC-2.O#CONDUCT POST-REPAIR INSPECTIONS AND VERIFICATION TESTING ASNECESSARY.3. RESPONSIBILITIES·#THE INSPECTION CONTRACTOR SHALL ENSURE QUALIFIED PERSONNEL (API510-CERTIFIED INSPECTORS, ND E TECHNICIANS) CONDUCT THE INSPECTIONS.·#DEWA SHALL PROVIDE NECESSARY ACCESS, PERMITS, OPERATIONAL DATA ANDARRANGE NDE CONTRACTORS·# ANY IDENTIFIED SAFETY HAZARDS SHALL BE PROMPTLY REPORTED ANDMITIGATED BEFORE PROCEEDING.4. DELIVERABLES·#PRE-INSPECTION PLAN·#INSPEC TION EXECUTION REPORT (INCLUDING NDE FINDINGS, PHOTOGRAPHICEVIDENCE, AND RECOMMENDATIONS)·#COMPLIANCE AND CERTIFICATION DOCUMENTATIO N·#REPAIR AND RE-INSPECTION REPORTS (IF APPLICABLE)·#PROVIDE FFS CERTIFICATE FOR 10 YEARS5. SAFETY AND COMPLIANCE·#ALL INSPECTIONS S HALL ADHERE TO SITE-SPECIFIC SAFETY REGULATIONS, PPEREQUIREMENTS, AND CONFINED SPACE ENTRY PROCEDURES.·#COMPLIANCE WITH OSHA, API, A SME, AND LOCAL REGULATORY STANDARDS ISMANDATORY.·#A JOB SAFETY ANALYSIS (JSA) SHALL BE CONDUCTED PRIOR TO THECOMMENCEMENT OF INSPECT ION ACTIVITIES.6. SCHEDULE AND EXECUTION PLAN. Qty: 1 Condition Assessment of Unfired Pressure Vessels at P1 S & D Dewa, Jabal Ali Power Station STANDARD TERMS & CONDITIONS 1) Prices should be DDP delivery duty paid at DEWA stores. 2) Quotation to be submitted only in local currency U.A.E Dirhams 3) DEWA Standard payment terms is 30 days credit from the date of acceptance of material 4) No DEWA staff or his or her relatives up to third degree should have ownership or partnership in your company, and your participation in DEWA tenders / RFQs should not constitute a Conflict or perceived Conflict of Interest. Supplier Registration: https://srm.dewa.gov.ae/irj/portal/anonymous/regis Tender Link : https://srm.dewa.gov.ae/sap/opu/odata/sap/ZSRM_RFX_REG_BID_SRV/AttachmentSet(2332501715)/$value

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail