GTR 98921899
Tenders Are Invited For Modernization Increasing The Energy Efficiency Of Public Buildings In The Pieńsk Commune.
ICB — International Competitive Bid
Closed
central europe
Tender Information
GTR Reference
98921899
Tendering Authority
Subscribe to view
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Modernization Increasing The Energy Efficiency Of Public Buildings In The Pieńsk Commune.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
central europe
Political Region
European Union
Last Date of Bid Submission
31-07-2025
Closed
Work Detail
The Subject Of The Contract Is Modernization That Increases The Energy Efficiency Of Public Buildings In The Pieńsk Commune. The Facilities Covered By The Modernization Are A Rural Club Room In The City Of Forests And The City And Commune Office In Pieńsk. As Part Of The Task, The Following Construction Works Are Expected To Be Carried Out: A) For The Common Room Building In Forests-Modernization Of The External Walls Of The Building With Polystyrene Thermal Insulation Thickness 15 Cm, The Thermal Insulation Used Material Is Graphite Polystyrene 033 (E.G. Termo Organica Or Equivalent), In The Eps System With Plaster,-Window Joinery. 0.900 W/(M2 ・ K),-Replacement Of The Door Joinery In The Building, Required Coefficient For The New Joinery: 1.300 W/(M2 ・ K),-Insulation Of The Ceiling Near The Attic By Laying Mineral Wool Plates, The Required Thickness Of Additional Layer Of Thermal Insulation: 20 Cm,-Pouring The Ceiling Above The Basement From The Pur Foam From 025, The Thickness Of The Thermal Insulation Layer Required 9 Cm. Foam Insulation Pur Spraying Method,-Assembly Of Solar Installation, The Power Of Micro Installation 7.00 Kw,-Ventilation With Heat Recovery,-Control Of The Heat Pump With Replacement Of Cast Iron Radiators With Panel Radiators.-Assembly Of Unit Hot Water Heaters. Thermal 15 Cm, The Thermal Insulation Used Is Graphite Polystyrene 033 (E.G. Thermo Organika Or Equivalent), In The Eps System With Plaster, -Window Of Window Joinery In The Building, Required Coefficient For The New Joinery 0.900 W/(M2 😁 K), -Door Joinery In The Building, Required Coefficient For New Stool: 1,300 W/(M2 😁 K),-Insulation Of The External Flat Roof, Polystyrene, Required Thickness Of The Thermal Insulation Layer 15 Cm. The Thermal Insulation Material Used Is A Sandwich Panel With Papa Cladding Eps 100-038 Roof,-Pouring The Ceiling Above The Pur 025 Foam Basement, The Required Thickness Of The Thermal Insulation Layer 9 Cm. Pur Insulation With Pur Foam. Spraying Method. Morestation Of Solar Installation. Microidalation Power 20.00 Kw. -Ventilation With Heat Recovery. Important: The Detailed Scope Of Works Is Included In The Technical Documentation. When Valuing The Offer, The Contractor Uses The Content Of Technical Documentation, Does Not Value The Offer In Accordance With The Items Of The Bill Of Quantities. Technical Documentation And Description Of The Subject Of The Contract Is An Indicator Of The Scope And Price Of The Entire Investment Task. The Work Of Works Is Only Assistance In Determining The Scope Of Works Resulting From The Documentation. The Bill Of Quantities Is Not A Quantitative Basis For The Offer To Be Valued.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
d7bcff33-b9f8-4c0a-b2e0-99536af84ead.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.