Non-Medical Equipment Based On The Use Of Radiations – Strahlenschutzkabine. Two Microfocus X-Rays Should Be Integrated Into The Accessible Radiation Protection Cabin To Be Obtained. These Are Primarily Used For In Situ Μct Recordings And Expand The Pre-Handen Infrastructure Of The Pml. Since This Is A Modular Setup, Position Sacrifices And Changes In The Components (Detectors, Actuators, Etc.) Must Be Conceivable Over Time And Cannot Be Ruled Out. The Position Of The X -Ray Sources Is Fixed In A Defined Cuboid, And The Radiation Direction Does Not Change. The X-Ray Radiators To Be Integrated Into The Radiation Protection Cabin And Corresponding To The Safety Devices Have A Maximum Energy Of 200 Kev At 80 W Maximum Performance And 70 Kev At 250 W Maximum Performance. Both X -Rays Have A Conical Jet Opening Angle Of Max. 30 °. With Regard To The Interpretation Of The Ray Protection, A Non-Parallel Operation Of The Two Spotlights And Max. 2000 H Per Year