GTR 98426782

Bids Are Invited For Town Of High River - Ccmc Mechanical Systems

ICB — International Competitive Bid Closed Northern America
Tender Information
GTR Reference
98426782
Tendering Authority
Subscribe to view
Tender No
AB-2025-04372
Financer Name
Self-Funded
Work Title
Bids Are Invited For Town Of High River - Ccmc Mechanical Systems
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Northern America
Political Region
Asia-Pacific Economic Cooperation, APEC,G20,APAC (Asia Pacific)
Last Date of Bid Submission
10-07-2025 Closed
Work Detail
Background And Description Of The Project:The Town Of High River Is Looking For A Qualified Contractor To Complete An Assessment Of The Current Mechanical Systems Located At The Charles Clarke Health Clinic And Provide Prioritized Recommendations And Pricing.Scope Of The Services:The Charles Clarke Health Clinic Building Is A Two Story With Basement, Leed Certified Design And Construction And The Mechanical System Is A Conventional System For Small Buildings. 1.Electrical Preheat Coil Installation Assessmentthe Installation Of Electrical Preheat Coils In The Intake Ducts Servicing The Energy Recovery Ventilators (Ervs) Is To Be Evaluated. The Successful Candidate Shall Engage A Qualified Electrical Consultant To Review The Existing Power Distribution System And Confirm The Building’S Electrical Capacity To Support The Addition Of Preheat Coils.2.Building Management System (Bms) Reviewthe Building’S Current Building Management System (Bms), Enteliweb, Provides Limited User Access. The Contractor Shall Assess The Bms To Determine The Feasibility Of Integrating An Open-Source Or More Accessible Platform. This Assessment Must Ensure The System Allows Full Access To Temperature Controls And The Ability To Adjust Setpoints As Required.3.Elevate All The Mechanical Systems:•The System Is Heated With 2 Camus 300,000 Btuh Boilers Located In The Penthouse Mechanical Room.• Located Outdoors At Grade Is A 60-Ton Carrier Air Cooled Chiller Filled Glycol Water Solution. Glycol Is Piped To A Glycol / Water Heat Exchanger. Water Is Distributed To Fan Coils. •Hot Water And Chilled Water Are Distributed To 4 Pipe Fan Coils (Fan, Cooling Coil, Heating Coil And Filter) On Each Building Level. •Each Building Entrance Has Been Provided With Hot Water Fan Coils. O4 Pipe Fan Coils Obasement - 4 Fan Coils Size B @1, C@3 Omain Floor – 24 Fan Coils Size A@3, B@8, C@5, D@3, E@5 Osecond Floor – 27 Fan Coils Size A@6, B@12, C@5, D@2, E@2 •Ventilation To The Fan Coils Is Provided Via 11 Mitsubishi Energy Recovery Ventilators Obasement – 2 Energy Recovery Ventilatorsomain Floor – 5 Energy Recovery Ventilators Osecond Floor – 5 Energy Recovery Ventilators
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
d7a25ef8-ec82-4846-b8c9-274e7ce7ec36.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders