Bids Are Invited For Town Of High River - Ccmc Mechanical Systems

Tender Detail

98426782
AB-2025-04372
Self-Funded
Bids Are Invited For Town Of High River - Ccmc Mechanical Systems
NCB
Northern America
Asia-Pacific Economic Cooperation, APEC,G20,APAC (Asia Pacific)
10-07-2025

Work Detail

Background And Description Of The Project:The Town Of High River Is Looking For A Qualified Contractor To Complete An Assessment Of The Current Mechanical Systems Located At The Charles Clarke Health Clinic And Provide Prioritized Recommendations And Pricing.Scope Of The Services:The Charles Clarke Health Clinic Building Is A Two Story With Basement, Leed Certified Design And Construction And The Mechanical System Is A Conventional System For Small Buildings. 1.Electrical Preheat Coil Installation Assessmentthe Installation Of Electrical Preheat Coils In The Intake Ducts Servicing The Energy Recovery Ventilators (Ervs) Is To Be Evaluated. The Successful Candidate Shall Engage A Qualified Electrical Consultant To Review The Existing Power Distribution System And Confirm The Building’S Electrical Capacity To Support The Addition Of Preheat Coils.2.Building Management System (Bms) Reviewthe Building’S Current Building Management System (Bms), Enteliweb, Provides Limited User Access. The Contractor Shall Assess The Bms To Determine The Feasibility Of Integrating An Open-Source Or More Accessible Platform. This Assessment Must Ensure The System Allows Full Access To Temperature Controls And The Ability To Adjust Setpoints As Required.3.Elevate All The Mechanical Systems:•The System Is Heated With 2 Camus 300,000 Btuh Boilers Located In The Penthouse Mechanical Room.• Located Outdoors At Grade Is A 60-Ton Carrier Air Cooled Chiller Filled Glycol Water Solution. Glycol Is Piped To A Glycol / Water Heat Exchanger. Water Is Distributed To Fan Coils. •Hot Water And Chilled Water Are Distributed To 4 Pipe Fan Coils (Fan, Cooling Coil, Heating Coil And Filter) On Each Building Level. •Each Building Entrance Has Been Provided With Hot Water Fan Coils. O4 Pipe Fan Coils Obasement - 4 Fan Coils Size B @1, C@3 Omain Floor – 24 Fan Coils Size A@3, B@8, C@5, D@3, E@5 Osecond Floor – 27 Fan Coils Size A@6, B@12, C@5, D@2, E@2 •Ventilation To The Fan Coils Is Provided Via 11 Mitsubishi Energy Recovery Ventilators Obasement – 2 Energy Recovery Ventilatorsomain Floor – 5 Energy Recovery Ventilators Osecond Floor – 5 Energy Recovery Ventilators

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail