GTR 97512234
Bids Are Invited For Acquisition Of Infusion Pumps, Oximeters And Multiparameter Monitors To Meet The Needs Of The Municipal Health And Sanitation Secretariat Of Miranda/Ms, On An Emergency Basis.
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
97512234
Tendering Authority
Subscribe to view
Tender No
018/2025
Financer Name
Self-Funded
Work Title
Bids Are Invited For Acquisition Of Infusion Pumps, Oximeters And Multiparameter Monitors To Meet The Needs Of The Municipal Health And Sanitation Secretariat Of Miranda/Ms, On An Emergency Basis.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
06-06-2025
Closed
Work Detail
Parenteral Infusion Pump Hionah: System: Linear Peristaltic; Compatible With Universal Equivalents For Silicone -Based Infusion Pump; Shop Deviation With Standard Silicone Equipment: ± 5% Flow After Calibration (*); Infusion Rate: 1-699Ml/H, Increment: 1 Ml/H; Total Volume: 1-9999Ml/H, Increment: 1 Ml/H; Occlusion Pressure: 100 Kpa ~ 300Kpa; Kvo: Below 5Ml/H Kvo 1Ml/H And Above 5Ml/H Kvo Of 5Ml/H; Bolus: Fixed At 699 Ml/H; Air Bubbles Detector: Ultrasound; 2, 8 Inches Lcd Display; Alarm By Occlusion, Infusion Near The End, Air Bubbles, Open Door, Engine Failure, Finalizing Perfusion, Infusion Warning, Kvo State, Weak Battery, Power Failure, Pressure Failure, Door Failure And Lack Of Communication; Stop Infusing Automatically During The Alarm (Except For The Alarms? Near The End? And? Weak Battery?); Power Supply: Ac 100 ~ 240V, 50/60 Hz? Battery: Rechargeable Lithium Autonomy Of Approximately 4 Hours; Weight: 2Kg; Dimension: 143, 6Mm (C) × 151, 8Mm (L) × 195, 3M, Biolight M12 Multiparmetric Monitor With Adult Sensor, Neo/Ped. Pulse Pressure Variation (Delta Pp), 12 Inch Screen, Offers Additional Breathing Rate, 8 -Hour Battery, Ecg, 6 Derivations. - Fc Range: Adult 0A 300 Bpm/Neo 0 To 350 Bpm - Alarm Limit Resolution: 1Bpm - Identifies Brand Pulse Step - Bioimpedance Thoracic, With Asult/Pediatic/No 0-150Rpm - Oximetry Measurement: 0-100% - Monitored Parameters: Spo2, Fp, Ip, And Fr, Breath Spo2e Wave Wave - Nonvasive (Pni) Practice? Systolic, Diastolic, Medium And Pulse Frequency - Cuff Insufflation Range: 0-300 Mmhg - Channels: 2, 2 Pi Parameter Channels (Including Systolic, Diastolic, Average, Pulse Frequency) And Wave. Measurement Points: Art, Pvc, Pic, Pa, Aouap, Bap, Fap, Lap, Rap, Uvo, Lv, Pwp, More Pi And P2 For Arbitrary Ponts - F A I X A D E M E D A: 5 0 ~ + 3 6 0 M H G., Oximeter With Temperature Measurement, Spo2 And Pulse Frequency: Deos Parameters Measured By Oximeter Include: Body Temperature, Arterial Oxygen Saturation (Sp02), Pulse Frequency (Fp), Bar Charts And Pleismo. The Oximeter Measures These Parameters Through A Sp02 Sensor And A Temperature Sensor And Displays Them On The Lcd Colored Screen After A Certain Additional Processing. Take For Transportation And Easy To Use; Silicone Protection, And Stable Support For Table Use; Db9 Type Connector; ? Supports Oximetry Sensor For Adults, Children And Neonates (See Models Available At The Time Of Purchase); 2 Inch Color Lcd Tft Lcd Screen Displaying Spo2/ Fp/ Pulse/ Plaphic Bar Graph/ Temperature; Visual And Sound Indicative Alerts, With Adjustable And Programmable Limits; Maximum And Minimum Limits Adjustable And Programmable For Sp2 And Heart Rate; Indicative Alert When Without Sensor And Sensor Out Of The Finger; Alert Indicative Of Weak Battery Voltage;
Key Value
Tender Value
102,826 - BRL
Tender Documents
Global Tender Document
603a846a-1130-4375-a714-6002ad35787e.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.