GTR 96546947
Bids Are Invited For Acquisition Of A Digital Rx Device, An Ultrasound To Be Used At Upa-24 Hs And Chambers For Preservation Of Medicines And Immunobiologicals, Following The Request Of The Municipal Health Secretariat.
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
96546947
Tendering Authority
Subscribe to view
Tender No
20/2025
Financer Name
Self-Funded
Work Title
Bids Are Invited For Acquisition Of A Digital Rx Device, An Ultrasound To Be Used At Upa-24 Hs And Chambers For Preservation Of Medicines And Immunobiologicals, Following The Request Of The Municipal Health Secretariat.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
26-05-2025
Closed
Work Detail
Ultrasound Device Without Application Transesophageal Ultrasound Device For The Following Clinical Applications: Obstetrics, Gynecology, Fetal Echocardiography, Adult And Pediatric Echocardiography, Small Parts, Vascular, Pediatrics, Breast, Skeletal Muscle, Urology And Internal Medicine/General Image. M, Color Doppler, Power Doppler, Pulse Spectral Dp Doppler, Continuous Spectral Dc Doppler, Tdi (Tissular Doppler Diagnosis), Odt Mode (Tissular Doppler Wave), Combined Mode (2D/C/C/C/Pd/Pd/C/C/Dc Mode, 2D/Pd/Dc Mode, Mode Mode/Pd/Dc, Mode 2D/C/M, 2D/Idt/Odt Mode, Dual Live Mode), Multi-Image Mode (Double Mode And Fad Mode), 3D/4D Mode. Transducers: The Transducers Must Be Multifrequently, Broadband And Allow The Selection Of At Least 03 Different Frequencies For 2D Mode; Frequency. We Request 4 Transducers Covering The Indicated Ranges. Multifreth Electronic Broadband Endocavitary Frequently From 4, 0 To 10, 0 Mhz; 4) Multifreth Broadband Adult Sector Transducer With Frequency Of 1, 0 To 5, 0 Mhz; Standard Specification: Compact, Lightweight And Easy Mobility Equipment - Has Four Wheels Articulated With Front Locks And Front Handles; Command Panel With Height Adjustment; Touch Screen Screen Of At Least 10 Inches; Full Hd Led Monitor Of At Least 21.5 Inch High Definition With Fully Articulated Arm In Angulation, Rotation And Slope. With Your Movements ..., High-High-Frequency High-Voltage Fixe-Generational X-Ray 380V, 50/60Hz Or Higher, Microprocessed Command, Minimum 52Kw Or Higher Power, Voltage Selection (Kv) Of 40 To 150 Kv Or Higher, With 1 Kv Steps. Variable Current In The Minimum Range Of 20 Ma Or Less Than 800 Ma Or Larger. With But Variable In The Range Of 1Mas Or Less Than 800 But Or Larger; Selection Of Exposure Time Of 5 Ms Or Lower Up To 5 Seconds According To Rdc 611; Overload Protection Device And Automatic Network Compensation. X-Ray Tube: X-Ray Pipe With Rotating Anode, Minimum Anode Thermal Capacity 300 Khu; Minimum Rotation Speed Of The Anode From 9,000 Rpm To 180 Hz Or Higher. Fine Focus Of 0, 6 Mm Or Smaller And Thick Focus Of 1, 2 Mm Or Smaller; Insertion Of Additional Ass Or Al; Power Of At Least 20 Kw For Thin And Minimum 52 Kw Focused Focus For Thick Focus, Manual Or Automatic Bright Collimator With Lamp And Timer. Integrated X-Ray Generator Command Panel With Image Detector Commands. Selection Of Pre-Programmed Anatomical Programs With The Possibility Of User Editing With A Capacity Of 200 Programs Or Higher; Selection Of Levels Of Kv, Ma And But At Least; Minimum Digital Indication Of Kv, Ma And But Should Be Stored And Sent With The Image For Each Exhibition. Exam Table: Fixed Table With Floating Top In The Four Senses With Electromagnetic Brakes Triggered By
Key Value
Tender Value
625,913 - BRL
Tender Documents
Global Tender Document
f410e69d-d96a-4a7e-8b81-2d92ab140e83.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.