Tenders Are Invited For Purchase Of Sterilization, Disinfection And Hygiene Devices-Ethylene Oxide Gas Sterilizer With Abator

Tender Detail

96510031
307636-2025
Self-Funded
Tenders Are Invited For Purchase Of Sterilization, Disinfection And Hygiene Devices-Ethylene Oxide Gas Sterilizer With Abator
NCB
central europe
European Union
23-06-2025

Work Detail

Purchase Of Sterilization, Disinfection And Hygiene Devices-Ethylene Oxide Gas Sterilizer With Abator. For The Petz Aladár University Teaching Hospital In Győr-Moson-Sopron County, 1 New Ethylene Oxide Gas Sterilization Equipment (Abator), Including All Accessories Required For Operation (Closed Catalyst, Ventilator, Ventilator, . 1 New Ethylene Oxide Gas Sterilizing Device (At The Latest, Not Used In 2024) Ethylene Oxide Gas Sterilization Requirements Are As Follows: • Operated At 55 And 37 ° C • Min. Have A Volume Of 130 Liters • Be Compatible With The Current Afterburner (3M Ea Abator 50Ae 1700 Types Of Board) Two -Door. Commissioning, • Teaching At Least One Person, 4 Hours • Transfer Of Hungarian -Language Manual And Instructions And Documents Required For Commissioning, • In The Absence Of A Hungarian Manual And Instructions, The Hungarian Language And Instructions Translated By The Tenderer And Instructions In The Same Content, Technician Hourly Fee, Required Checks, Replacement Parts) 1 Pc Ethylene Oxide Catalyst (Abator), Including All Equipment, Accessories (Closed Catalyst, Air Heating, Fans, Control) The Task Of Abator Is To Convert The Ethylene Oxide Into Carbon Dioxide And Water. Expected Efficiency Is At Least 95%. The Winners Tenderers Task Is: • Delivery, • Installation, • Teaching At Least One Person, 4 Hours • Transfer Of Hungarian -Language Manual And Instructions And Documents Required For Commissioning • Unless The Hungarian Language Manual And Instructions Are Used, Maintenance (Including The Required Exit, Technician Hourly Fee, Required Checks, Replacement Parts) Can Only Be Recommended By Abator, Which Is Compatible With The Ethylene Oxide Gas Sterilization Device To Be Offered. The Offered Device Must Be A Medical Device Classified As Class I, So It Must Comply With Decree 4/2009. (Iii.17.) Eüm, They Must Have A Manufacturers Conformity Declaration And, If Necessary To Put The Medical Device On The Market Under The Regulation On Medical Devices, Ce Conformity Evaluation Certificate

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail