GTR 96438769
Tenders Are Invited For Reagents And Consumables To The Analyzer Cobas C311 Biochemistry
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
96438769
Tendering Authority
Subscribe to view
Tender No
14631036
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Reagents And Consumables To The Analyzer Cobas C311 Biochemistry
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
20-05-2025
Closed
Work Detail
Trsf Transferrin Cassette (Transferrin) For 100 Tests. Reagents For The Analyzer Cobas C311. Trsf Transferrin Cassette (Transferrin) For 100 Tests. Purpose. In Vitro Test For The Quantitative Determination Of Transferrin In Human Urine On Roche/Hitachi Cobas C. Reagents - Working Solutions: R1 Phosphate Buffer: 55 Mmol/L, Ph 7.2; Nacl: 25 Mmol/L; Polyethylene Glycol: 5 %; Conservative R2 Antibodies Against A Person’S Transfer (Rabbit): Depends On The Titer; Nacl: 100 Mmol/L; Conservice. Ready For Use. Storage And Stability Trsf2. Shelf Life At 2 8 ° C: See The Shelf Life On The Label Of The Cobas Cobas C. C.S. Storage Of The Opened Reagent In The Refrigerator On Board The Analyzer: 8 Weeks. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Supply Area Is For Eu Countries. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification., Calcium Calcium Calcium (Calcium) 300 Tests. Reagents For The Analyzer Cobas C311. Calcium Calcium Calcium (Calcium) For 300 Tests. Purpose: A Test For Diagnosis In Vitro, Designed To Quantify Calcium In Human Serum, Plasma And Urine. Reagents And Working Solutions: R1 Capso: A) 557 Mmol/L; Nm Bapta: 2 Mmol/L, Ph 10.0; Unreactive Surfactant; Conservice Sr Edta: 7.5 Mmol/L; Ph 7.3; Unrealistic Suffractor; Conservice. Storage And Transportation Conditions: Store In The Refrigerator. The Expiration Date At 2 8 ° C Cm Cm. The Expiration Date On The Label Of The Cobas C When Used On Board The Analyzer At 10 15 ° C 12 Weeks. Transportation Is Mandatory In Thermal Containers With Refrigerated Elements At A Temperature Of 2-8 ° C, Not To Be Frozen And The Effects Of High Temperature. Calibration Is Linear At Two Points, The Frequency Of Calibration - After A Change In The Lot. Measurement Range 0.20 5.0 Mmol/L (0.8 20.1 Mg/Dl). The Lower Dough Detection Limit 0.10 Mmol/L (0.4 Mg/Dl). The Reproducibility Of The Test Is Not More Than 0.8 %. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Supply Area Is For Eu Countries. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification., Acid Wash Solution (Detergent 2) 2X1.8 Liter Solution. Reagents For The Analyzer Cobas C311. Acid Wash Solution (Detergent 2) Solution 2 Containers Of 1.8 Liters. Purpose: Acid Wash Solution (Detergent 2) Is Used As An Acid Flushing Solution For Reaction Cells And Sampling Probes On The Roche/Hitachi Devices And Working Solutions: Storage And Transportation Conditions: Store At Room Temperature. The Shelf Life Of The Open Reagent In The Coolant For Reagents On Board The Analyzer Is 1 Week. Do Not Expose Mechanically, Do Not Freeze And The Effects Of High Temperature. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Supply Area Is For Eu Countries. The Residual Expiration Date Is At Least 60%. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification., Auxiliary Solution Sample Cleaner 1 (12 Bottles Of 59 Ml). Reagents For The Analyzer Cobas C311. Auxiliary Solution Sample Cleaner 1, 12 Bottles Of 59 Ml. Purpose: Flushing Solution For Samplers Used On Roche/Hitachi Cobas C. Reagents - Working Solutions: Branding Of Sodium Hydroxide 1 Mol/L. Storage And Transportation Conditions: Store At Room Temperature. The Shelf Life Of The Open Reagent In The Coolant For Reagents On Board The Analyzer Is 1 Week. Do Not Expose Mechanically, Do Not Freeze And The Effects Of High Temperature. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Supply Area Is For Eu Countries. The Residual Expiration Date Is At Least 60%. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification., Auxiliary Solution Naoh-D 41.2 Ml. Reagents For The Analyzer Cobas C311. Auxiliary Solution Naoh-D 41.2 Ml. Flushing Solutions For Samples Of The Reagent And/Or Reaction Chambers For Analyzers. Purpose: To Exclude The Influence Of Other Samples Or Samples On The Result Of The Current Analysis, A Reagent And Flushing Solutions For The Sampler Or Chamber May Be Required. The Solution Supports The Invariability Of Reagents And Samples. Reagents - Working Solutions: Naohd: Naoh 1 Mol/L (Trim 4 %); Detergent Sms: Hcl 200 Mmol/L Smpcln1: Naoh 1 Mol/L Smpcln2: Buffer; Detergent Special Cell Cleaning Solution: Naoh 3 Mol/L (Priest 12 %); Sodium Hypochlorite Solution (<2 % Active Chlorine); Added Substance. Storage And Transportation Conditions: Store At Room Temperature. The Shelf Life Of The Open Reagent In The Coolant For Reagents On Board The Analyzer Is 1 Week. Do Not Expose Mechanically, Do Not Freeze And The Effects Of High Temperature. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Supply Area Is For Eu Countries. The Residual Expiration Date Is At Least 60%. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification., Cassette Cholen Chol (Cholesterol) 400 Tests. Reagents For The Analyzer Cobas C311. Cholesterin Cassette Chol (Cholesterol) For 400 Tests. Purpose: The In Vitro Diagnostics Test For The Quantitative Determination Of The Total Cholesterol In Serum And Blood Plasma On Cobas Analyzers. Reagents And Working Solutions: R Pipesa): 225 Mmol/L, Ph 6.8; Mg2+: 10 Mmol/L; Sodium Hulat: 0.6 Mmol/L; 4 Aminoantipirin: ≥ 0.45 Mmol/L; Phenol ≥ 12.6 Mmol/L; Polyglycolic Ether Of Fat Alcohols: 3 %; Cholesterolesterase (Pseudomonas Spec.): ≥ 25 Μtat/L (≥ 1.5 E/Ml); Cholesteroloxidase (E. Coli): ≥ 7.5 Μat/L (≥ 0.45 E/Ml); Peroxidase (Horseradish): ≥ 12.5 Μat/L (≥ 0.75 E/Ml); Stabilizers; Preservative A) Pipes = Buffer Solution Of Pipeperizin-1,4-Bys (2-Eve Sulfonic Acid R Is In Position B. Storage And Transportation Conditions: Store In The Refrigerator. Shelf Life At 2 8 ° C Cm Cm. Cobas Cube Leaflet. When Using The Analyzer At 10 15 ° C 8 Weeks. Transportation Is Mandatory In Thermal Circuitaries With Thermal Circuit Breakers With The Refrigerators At A Temperature Of 2-8 ° C, Do Not Freeze And The Effects Of High Temperature The Test Is Not More Than 0.9 %., Auxiliary Sample Cleaner 2 (12 Bottles Of 68 Ml). Reagents For The Analyzer Cobas C311. Auxiliary Solution Sample Cleaner 2, 12 Bottles Of 68 Ml. Purpose: Flushing Solution For Samplers Used On Roche/Hitachi Cobas C. Reagents - Working Solutions: Buffer; Detergent. Storage And Transportation Conditions: Store At Room Temperature. The Shelf Life Of The Open Reagent In The Coolant For Reagents On Board The Analyzer Is 1 Week. Do Not Expose Mechanically, Do Not Freeze And The Effects Of High Temperature. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Supply Area Is For Eu Countries. The Residual Expiration Date Is At Least 60%. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification., Magnesium Cassette Mg (Magnesium) For 250 Tests. Reagents For The Analyzer Cobas C311. Magnesium Cassette Mg (Magnesium) For 250 Tests. Purpose: Set For In Vitro Diagnostics. Designed For The Quantitative Determination Of Magnesium In Serum, Plasma And Urine On Roche/Hitachi Cobas C Analyzers. Reagents And Working Solutions: R1 Trisa /6 Buffer Solution Of Aminocaprone Killer: 500 Mmol /L, Ph 11.25; Egtk: 129 Μmol/L; Conservice R2 Xilidyl Blue: 0.28 Mmol/L; Detergent; Conservice A) Tris = Tris (Hydroxymethyl) Aminomethan R1 Is In Position B, R2 - In Position C. Storage And Transportation Conditions: Store In The Refrigerator. The Expiration Date At 2 8 ° C Cm Cm. The Expiration Date On The Label Of The Cobas C When Used On Board The Analyzer At 10 15 ° C 6 Weeks. Transportation Is Mandatory In Thermal Containers With Refrigerated Elements At A Temperature Of 2-8 ° C, Not To Be Frozen And The Effects Of High Temperature. Calibration Is Linear At Two Points, The Frequency Of Calibration - After A Change In The Lot. Measurement Range 0.10 2.0 Mmol/L (0.243 4.86 Mg/Dl). The Lower Dough Detection Limit 0.10 Mmol/L (0.243 Mg/Dl). The Reproducibility Of The Test Is Not More Than 0.8 %. The Reagents For The Cobas Analyzer From 501. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Supply Area Is For Eu Countries. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification., Ecotergent, 44 Ml. Reagents For The Analyzer Cobas C311. Cleaning Solution: Ecotergent, Cobas C311, Cassettes Volume 44 Ml. Purpose: Ecotergent Is An Additive For Reducing Surface Tension In The Reaction Bath Of The Cobas C Analyzer. Hitergent Is Added To The Reaction Bath. It Acts As A Surface-Active Substance And Minimizes The Formation Of Bubbles, Which Are Potentially Capable Of Affecting The Readings Of The Photometer. Reagents - Working Solutions: Detergent. Storage And Transportation Conditions: Store At Room Temperature. The Shelf Life Of The Open Reagent In The Coolant For Reagents On Board The Analyzer Is 1 Week. Do Not Expose Mechanically, Do Not Freeze And The Effects Of High Temperature. The Supply Area Is For Eu Countries. The Residual Expiration Date Is At Least 60%. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification., Naoh-D Basic Wash (Detergent 1) 2X1.8 Liter Solution. Reagents For The Analyzer Cobas C311. Naoh-D Basic Wash (Detergent 1) Solution 2 Containers Of 1.8 Liters. Purpose: Naoh -D / Basic Wash Is Used As An Alkaline Flushing Solution For Reaction Cells And Sampling Probes On Roche / Hitachi Devices And Working Solutions: Storage And Transportation Conditions: Store At Room Temperature. The Shelf Life Of The Open Reagent In The Coolant For Reagents On Board The Analyzer Is 1 Week. Do Not Expose Mechanically, Do Not Freeze And The Effects Of High Temperature. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Supply Area Is For Eu Countries. The Residual Expiration Date Is At Least 60%. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification., Cassette Albumin Immuniurbidimetric Albt (Albumin Immunoturbidimetric) 100 Tests. Reagents For The Analyzer Cobas C311. Albumin Cassette In The Urine For 100 Tests. Purpose: Set For In Vitro Diagnostics. Designed For The Quantitative Immunological Determination Of Human Albumin In Serum, Plasma, Urine And Smzh. Reagents - Working Solutions: R1 Trisa) Boofer: 50 Mmol/L, Ph 8.0; Peg: ≥ 4.2 %; Edta: 2 Mmol/L; Conservative R2 Polyclonal Anti-Human Antibodies Of Albumin (Sheep): Different Titers; Tris) Boofer: 100 Mmol/L, Ph 7.2; Conservative Sr Reagent To Check The Excess Antigen Albumin In Diluted Serum (Person); Phosphate Buffer: 50 Mmol/L, Ph 7.0; Preservative A) Tris = Tris (Hydroxymethyl)-Aminomethane R1 Is In Position A, R2 - In Position B, And Sr - In Position C. Storage And Transportation Conditions: Store In The Refrigerator. The Shelf Life At 2-8 ° C Cm. When Using The Analyzer On Board At 10-15 ° C 12 Weeks. Transportation Is Mandatory In Thermal Containers With Refrigerated Elements At A Temperature Of 2-8 ° C, Not To Be Frozen And The Effects Of High Temperature. Calibration Is Linear At Six Points With Automatic Dilution, The Calibration Frequency - After The Change Of Lot. The Lower Dough Detection Limit Is 18 Mg/L (0.274 Μmol/L Or 1.8 Mg/Dl). The Reproducibility Of The Test Is Not More Than 0.9 %. The Supplier Is Obliged To Provide A Certificate Of The Origin Of The Goods, The Deadline For Replacing Low-Quality And Inappropriate Goods: Within 3 Business Days. When The Goods Are Passed, The Presence Of A Representative Of The Supplier Is Mandatory., Cassette Uric Acid Ua (Uric Acid) For 400 Tests. Reagents For The Analyzer Cobas C311. Cassette Uric Acid Ua (Uric Acid) For 400 Tests. Purpose: Set For Diagnosis In Vitro. Designed For The Quantitative Determination Of The Concentration Of Uric Acid In Serum, Plasma And Urine. Reagents And Working Solutions: R1 Phosphate Buffer: 0.05 Mol/L, Ph 7.8; Toos: 7 Mmol/L; Polyglycolic Ether Of Fat Alcohol: 4.8 %; Ascorbatoxidase (Ec 1.10.3.3; Tsukkini) ≥ 83.5 Μtat/L (25 ° C); Stabilizers; Conservative Sr Phosphate Buffer: 0.1 Mol/L, Ph 7.8; Haecsicano -Firing Potassium (Ii): 0.3 Mmol/L; 4 Aminophenazone ≥ 3 Mmol/L; Urizcin (Ec 1.7.3.3; Arthrobacter Protophormiae) ≥ 83.4 Μat/L (25 ° C); Peroxidase (Under) (Ec 1.11.1.7; Horseradish) ≥ 50 Μat/L (25 ° C); Stabilizers; The Preservative R1 Is In Position B, Sr - In Position C. Storage And Transportation Conditions: Store In The Refrigerator. The Expiration Date At 2 8 ° C Cm Cm. The Expiration Date On The Label Of The Cobas C When Used On Board The Analyzer At 10 15 ° C 6 Weeks. Transportation Is Mandatory In Thermal Containers With Refrigerated Elements At A Temperature Of 2-8 ° C, Not To Be Frozen And The Effects Of High Temperature. Calibration Is Linear At Two Points, The Frequency Of Calibration - After A Change In The Lot. Measurement Range 11.9 1500 Μmol/L (0.20 25 Mg/Dl). The Lower Dough Detection Limit Is 11.9 Μmol/L (0.20 Mg/Dl). The Reproducibility Of The Test Is Not More Than 1.8 %. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Supply Area Is For Eu Countries. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification.
Key Value
Tender Value
607,693 - KZT
Tender Documents
Global Tender Document
cff5c727-15b7-4a13-90bd-b2a7bbbe5e03.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.