GTR 96203189

Request For Quotation Acquisition Of Medical Devices For Paid Services.

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
96203189
Tendering Authority
Subscribe to view
Tender No
14680664
Financer Name
Self-Funded
Work Title
Request For Quotation Acquisition Of Medical Devices For Paid Services.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
08-05-2025 Closed
Work Detail
The Reagent Is Used For Quantitative Measurement In Vitro Immunoglobulin-M (Igm) In A Human Blood Serum On The Dirii Cs-T240 Biochemical Analyzer. Serum Or Plasma Is Mixed With Antibodies Against Human Igm In The Reagent, Which Leads To The Formation Of The Antigen-Antibodulation Complex, While A Certain Degree Of Turbidity Is Formed, The Intensity Of Which Is Directly Proportional To The Igm Content In Serum. The Content Of Igm In The Serum Can Be Calculated By Measuring The Absorption Of Turbidity At 340 Nm And A Comparison With A Standard Curve. Reagents: R1 -Buer. R2- A Solution Containing A Goat Antibody Against An Igg Person. The Test Time Is 5 Minutes. Volume R1 - 50 Ml. Volume R1 -10 Ml. Sample Volume 3 Μl. The Number Of Tests In The Package Is Not More Than 112. The Calibrator In The Set. The Reagent Control Is Carried Out Under The Control For Specific Proteins Level 1 And 2. The Calibrator And Control Of The Manufacturer’S Factory With Passport Values ​​Of The Control Material And A Calibrator With Target Value. The Linear Range Of This Reagent Is 0.05 -3 G/L. Reagents Are Delivered In A Disposable Factory Packaging (Bottle). The Bottle Has An Individual Bar Code That Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, The Date Of The Expiration Date Of The Reagent. The Touch Code Code Should Be Compatible With The Analyzer Os And The Analyzer Security System. The Bar Code Is Not Allowed And Damage. The Distance Between The Bottom Of The Bottle And The Bar Must Correspond To The Range Of 15Mm-25Mm. The Purchase Of The Goods Includes A Related Service: Departure Of A Certified Specialist To Adapt The Reagent .. For The Completion, Modernization And Removal Of The Main (Installed) Equipment. Gost R 51352-99, General Bilirubin (Total Bilirubin)- Tb. The Reagent Is Used For Quantitative Measurement In Vitro Concentration Of General Bilirubin (Tb) In Serum Or Blood Plasma On The Dirii Cs-T240 Biochemical Analyzer. In The Reagent, Surfactant Is Used As A Solvent. The Bound Bilirubin And Unrelated Bilirubin, Which Were Dissolved, React With Diazophanilic Acid, As A Result Of Which Azaso-Bilirubin Is Formed. An Increase In Light Absorption With A Wavelength Of 570Nm In Proportion To The Concentration Of The Total Bilirubin. The Concentration Of The General Bilirubin In The Sample Can Be Calculated By Checking The Change In Absorption At The Wavelength Of 570 Nm. When Analyzing A Double Beam, The Idle Wavelength Should Be Tuned To The Nat 750Nm. Components: Reagent 1 - Hydrochloric Acid 100 Mmol/L; Sulfanilic Acid 5 Mmol/L. Reagent 2- Nitrite Sodium 72 Mmol/L. The Exchange Of Components From Various Batch Of Reagents Is Prohibited. The Duration Of The Reaction Is 300-600 Seconds. The Linear Range Of This Reagent Is 0 ~ 300 Μmol/L. The Volume Of R1-250 Μl. Exhibition Of Sample-25 Μl .. The Number Of Tests In The Package Of At Least 1068. Caliber In The Set. Calibration Of The Reagent Is Also Carried Out On A Multi -Grab. The Reagent Control Is Carried Out On The Multicortral Level 1 And 2. Reagents Are Delivered In A Disposable Factory Packaging (Bottle). The Bottle Has An Individual Bar Code That Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, The Date Of The Expiration Date Of The Reagent. The Touch Code Code Should Be Compatible With The Analyzer Os And The Analyzer Security System. The Bar Code Is Not Allowed And Damage. The Distance Between The Bottom Of The Bottle And The Bar Must Correspond To The Range Of 15Mm-25Mm. For Understaffing, Modernization And Completion Of The Main (Installed) Equipment. Gost R 51352-99
Key Value
Tender Value
583,635 - KZT
Tender Documents
Global Tender Document
37925f2a-e7dd-4f42-a87e-a3bb87a8b06e.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.