GTR 94736069

Request For Quotation Medical Supplies

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
94736069
Tendering Authority
Subscribe to view
Tender No
14376565
Financer Name
Self-Funded
Work Title
Request For Quotation Medical Supplies
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
02-04-2025 Closed
Work Detail
Volume (Packing): 2X50 Ml The Set Is Intended For Use On Any Biochemical Analyzers Of An Open Type Produced From High -Quality Imported Raw Materials Linearity Range: From 10 To 440 Units/L The Low Coefficient Of Variation Of The Results Of The Definitions Is Not More Than 5%. The Calibrator Is Part Of The Set Antametaminotransferase Enzyme (L-Aspartet: 2-Oxoglutarate Aminotransferase; K.F. 2.6.1.1)-Asat Or Ast, Catalyzes The Reversible Transfer Of Aminogroups From The L-Aparte To Α-Cutglutar Acid With The Formation Of Oxaloacetate. From Oxaloacetate, Under The Influence Of The Enzyme Mdg (Malathdehydrogenase), A Malate Is Formed, While The Nadn Passes Into An Oxidized Form Over. The Oxidation Speed Of The Nadn Is Directly Proportional To The Activity Of Alanineaminotransferase And Is Measured Photometrically With A Wavelength Of 340 Nm., Lysercell Wdf (Lysercell Wdf Lizing Reagent) (For The Hematological Analyzer Sysmex Xn-550) 1 X 2 L, Determining The Concentration Of C-Reactive Protein In Serum With A Manual Method Of 10 Ml, The Linear Area For Determining The Concentration Of Iron Is In The Range From 5.0 To 179 Μmol/L, Deviation From Linearity - No More Than 5%. The Sensitivity Of The Definition Is Not More Than 3.0 Μmol/L. The Coefficient Of Variation Of The Results Of The Definitions Is Not More Than 5%. The Quality Of The Set Can Be Checked Using Domestic Or Foreign Control Serums With An Indicator Certified By This Method. Normal Values ​​Of Iron In Serum (Plasma) Of Blood: Men - 9.5-30 Μmol/L, Women - 8.8-27 Μmol/L. It Is Recommended That In Each Laboratory Clarify The Range Of Normal Values ​​For The Examined Contingent. (For A Biochemical Analyzer, The Semiautomatic Device Vts-350), Volume (Packing): 9X15ml The Set Is Intended For Use On Any Biochemical Analyzers Of An Open Type Produced From High -Quality Imported Raw Materials Linearity Range: From 1 To 11.3 Mmol/L The Low Coefficient Of Variation Of The Results Of The Definitions Is Not More Than 5%. The Calibrator Is Part Of The Set Lipoproteinlipase Catalyzes The Reaction Of Triglycerides Hydrolysis With The Formation Of Fatty Acids And The Equimolar Amounts Of Glycerin. Glycerin In The Presence Of Atp, Hexokinase And Glycerophosphatoxidase Is Oxidized With Oxygen Of Air With The Formation Of An Equimolar Amount Of Hydrogen Peroxide. In The Presence Of Peroxidase, Hydrogen Peroxide Oxidizes 4-Aminoantipirin And Chlorophenol With The Formation Of Red Chinemin, Staining Intensity, Measured At 505 Nm, In Proportion To The Concentration Of Triglycerides In The Sample. (For A Biochemical Analyzer, Vts-350 Semi-Automatic, Volume (Packing): 4X100ml The Set Is Intended For Use On Any Biochemical Analyzers Of An Open Type Produced From High -Quality Imported Raw Materials Linearity Range: From 20 To 120 G/L, The Low Coefficient Of Variation Of The Results Of The Definitions Is Not More Than 5%. The Calibrator Is Part Of The Set Proteins React In An Alkaline Environment With Copper Sulfate, Forming A Compound Painted In Purple, The Intensity Of Which Is Proportional To The Concentration Of Protein. (For A Biochemical Analyzer, Vts-350 Semi-Automatic, Volume (Packing): 200 Ml Reagent 1 - 1X100ml, Reagent 2 - 1X100ml, Enzyme Reagent - 1X1ml, Standard For Reagents: 1X3ml. The Set Is Intended For Use On Any Biochemical Analyzers Of An Open Type Produced From High -Quality Imported Raw Materials Linearity Range: From 2 To 50 Mmol/L The Low Coefficient Of Variation Of The Results Of The Definitions Is Not More Than 5%. The Calibrator Is Part Of The Set Under The Influence Of Ureases, Urea Turns Into Ammonia And Carbon Dioxide. Ammonia, Interacting With Α-Methulutaric Acid With The Participation Of Glutamat Dehydrogenase (Gldg), Oxidizes The Restored Nicotnindininucleotide, The Optical Density Of Which At 340 Nm Decreases In Proportion To The Content Of Urea. (For The Biochemical Analyzer, Vts-350 Semi-Automatic, Volume (Packing): 2X100ml The Set Is Intended For Use On Any Biochemical Analyzers Of An Open Type Produced From High -Quality Imported Raw Materials Linearity Range: 3.0 - 425.0 Μmol/L. The Low Coefficient Of Variation Of The Results Of The Definitions Is Not More Than 7%. The Calibrator Is Part Of The Set. Bilirubin Interacts With Diazoted Sulfanilic Acid In The Presence Of Caffein With The Formation Of Painted Azic Compound, The Color Intensity Of Which Is Measured By Photometrically With A Wavelength Of 578 Nm. (For A Biochemical Analyzer, Vts-350 Semi-Automatic), Brucellosis Diagnosticum Manual Method, Cellclean 50 Ml 1 X 50 Ml (For The Hematological Analyzer Sysmex Xn-550), Volume (Packing): 200Ml The Set Is Intended For Use On Any Biochemical Analyzers Of An Open Type Produced From High -Quality Imported Raw Materials Linearity Range: 30 To 2212 Μmol/L The Low Coefficient Of Variation Of The Results Of The Definitions Is Not More Than 5%. The Calibrator Is Part Of The Set Creatinin In An Alkaline Environment Forms A Painted Complex With Picrinic Acid. The Reaction Rate Is Proportional To The Concentration Of Creatinine In The Sample. With This Measurement Method, The Effect Of Non -Specific Factors Decreases. Creatin Is Formed From Creatine - Acid, Which Is Involved In The Exchange Of Energy In Muscle Cells. Every Day, About 2% Of Nitrogen -Containing Carboxylic Acid Is Converted To Creatinine. It Enters The Kidneys Through Blood, Where Filtration Is Carried Out And Urina Is Formed. Most Of The Creatinine Is Excreted From The Reset Through The Kidneys. Over The Day, The Content Of Creatinine In The Blood Circulates At About The Same Level. This Is Because The State Of Muscle Mass Is Also Unchanged., Test Strips 10 Parameters: -Biochemical Components (Glucose, Protein, Ketones, Nitrites, Bilirubin, Urine Enogenes); Urines H 10 -Blood Cells (Hidden Blood, Leukocytes); -Physico-Chemical Indicators (Ph, Specific Gravity). Complexation: 100 Pcs./Up, A Plastic Penalty With A Moisture Absorber Urobilinogen, Bilirubin, Ketons, Ery Blood Cells, Protein, Nitrites, Leukocytes, Glucose, Orthly Density, Ph, Ascorbic Acid, Creatinine, Calcium, Microalbumin. (For The Diode Analyzer Cl-500), Fluorocell Wdf (Coloring Reagent Fluorocell Wdf) 2 X 22 Ml (For The Hematological Analyzer Sysmex Xn-550), Cellpack Dcl (Whole Blood Diluent Cellpack Dcl) (For The Hematological Analyzer Sysmex Xn-550) 1 X 10L, Sulfolyser (Reagent For Determining The Concentration Of Hemoglobin In The Blood) (For The Hematological Analyzer Sysmex Xn-550) 3X 500 Ml, Biochemical Calibrator (For A Biochemical Analyzer Semiautomatic Device Vts-350), Volume (Packing): 4X50 Ml 5X10 Ml The Set Is Intended For Use On Any Biochemical Analyzers Of An Open Type Produced From High -Quality Imported Raw Materials Linearity Range: From 15 To 3000 Units/L The Low Coefficient Of Variation Of The Results Of The Definitions Is Not More Than 5%. The Calibrator Is Part Of The Set Α-Amilasis Hydrolyzes The Substrate 2-Chloro-4-Α-Ode-D-Maltotrioside (Cnp-G3) To Carbohydrate Polymers And P-Nitropenil-Ooligosaccharide From Short Chains, And Forms 2-Chlorin-4-Nitrophenol (Cnp). To Determine The Activity Of Α-Amylase, The Rate Of Formation Of Cnp Is Measured On A Spectrophotometer With A Wavelength Of 405 Nm., Volume (Packing): 4X30ml 3X250ml 4X100ml The Set Is Intended For Use On Any Biochemical Analyzers Of An Open Type Produced From High -Quality Imported Raw Materials Linearity Range: 0.5 - 18.1 Μmol/L. The Low Coefficient Of Variation Of The Results Of The Definitions Is Not More Than 5%. The Calibrator Is Part Of The Set. Ethers Of Cholesterol Under The Influence Of Cholesterolesterase Turn Into Cholesterol, Which Is Oxidized Under The Influence Of Cholesteroloxidase, Forming Hydrogen Peroxide. Phenol And 4-Aminoantipirin, Under The Influence Of The Formed Peroxide Of Hydrogen And Peroxidase, Form A Painted Complex, The Color Intensity Of Which At 500-546 Nm Is Proportional To The Cholesterol Content. (For The Biochemical Analyzer, The Semiautomatic Device Vts-350), Biochemical Control I, Control Ii (For The Biochemical Analyzer Semiautomatic Device Vts-350), Xn-L Check L3 (Control Blood Xn-Lcheck L1) 1 X 3 Ml (For The Hematological Analyzer Sysmex Xn-550)
Key Value
Tender Value
9,979,732 - KZT
Tender Documents
Global Tender Document
61272100-d0ed-492f-bb71-787a25108dab.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders