GTR 94504805
Quotation Are Invited For Rectification Of Hvac Chiller-2 In Nhda 400Kv Transmission Substation
ICB — International Competitive Bid
Closed
Asia
Tender Information
GTR Reference
94504805
Tendering Authority
Subscribe to view
Tender No
2332500787
Financer Name
Self-Funded
Work Title
Quotation Are Invited For Rectification Of Hvac Chiller-2 In Nhda 400Kv Transmission Substation
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Asia
Political Region
Arab World1,Gulf Cooperation Council, GCC,Middle East,Middle East and North Africa, MENA
Last Date of Bid Submission
28-03-2025
Closed
Work Detail
Quotation are invited for Rectification of HVAC Chiller-2 in NHDA 400kV Transmission Substation. RECTIFICATION OF HVAC CHILLER-2 IN NHDA 400KV TRANSMISSION SUBSTATION.CHILLER # 2 (AIR COOLED)SAP EQUIPMENT NUMBER - 30346366MAKE: M CQUAY - DAIKINMODEL: ALR-145-2 HACNSERIAL NUMBER - 98-1-398/1ATTEND AND RECTIFY THE FOLLOWING POINTSSOLENOID COIL.1.#SCHNEIDER LC1D9 5 CONTRACTOR.2.#SCHNEIDER OLR LRD 3363.3.#SCHNEIDER LC1F115 CONTACTOR.4.#SCHNEIDER LR9F5367 OLR.5.#HP CUT-OUT SWITCHES.6.#LP CUT-OUT SWITCHES.7.#COOLER RECTIFICATION WITH LATH-MACHINE8.#CLEANING AND ANTI-CORROSION PAINTING FOR CASING OF CHILLER.9.#INSULATION WITH FOSTERING WORK.UNIT TO BE REINSTATED BACK AND HANDED OVER IN NORMAL WORKING CONDITION.NOTE:THE CONTRACTOR SHALL GIVE MINIMUM 1 YEAR WARRANTY FOR WORKMANSHIP ANDMATERIAL SUPPLY.FOR PTW APPLICATION, PLEASE SEND MAIL TO: [email protected] PERSON FOR SITE VIS IT:MR. ABDULLA MOHAMMAD ALMOHAMMAD ,ENGR - ELECTROMECHANICAL MAINTENANCE(TEL. 04-3221956 # MOBILE: 0555492824)MAILTO: ABDULLA.ALMOHA [email protected]##PAYMENT TERMS AND CONDITIONS:PENALTY: THE CONTRACTOR SHALL COMPLETE THIS WORK WITHIN 1 YEAR OF PORELEASE DATE, IF THE WORK IS DELAYED BEYOND THAT THEN; DEWA IS ENTITLEDTO A REDUCTION IN THE PO VALUE BY 1.25% PER WEEK OF DELAY AND SUBJECT TOMAXIMU M 10% OF PO VALUE.RETENTION AMOUNT: 5% OF THE TOTAL VALUE OF THE PO WILL BE KEPT AS ARETENTION AMOUNT FOR 1 YEAR AFTER THE COMPLETIO N CERTIFICATE IS ISSUED,IT WILL BE RELEASED TO THE CONTRACTOR UPON CLEARING ALL RELATED NODS. Qty: 1 Rectification of HVAC Chiller-2 in NHDA 400kV Transmission Substation. Chiller 2 (Air Cooled) Contact person for site visit: Mr. Abdulla Mohammad Almohammad ,Engr - Electromechanical Maintenance (Tel. 04-3221956 # Mobile: 0555492824) STANDARD TERMS & CONDITIONS 1) Prices should be DDP delivery duty paid at DEWA stores. 2) Quotation to be submitted only in local currency U.A.E Dirhams 3) DEWA Standard payment terms is 30 days credit from the date of acceptance of material 4) No DEWA staff or his or her relatives up to third degree should have ownership or partnership in your company, and your participation in DEWA tenders / RFQs should not constitute a Conflict or perceived Conflict of Interest. Supplier Registration: https://srm.dewa.gov.ae/irj/portal/anonymous/regis Tender Link : https://srm.dewa.gov.ae/sap/opu/odata/sap/ZSRM_RFX_REG_BID_SRV/AttachmentSet(2332500787)/$value
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
8c0c84e3-d958-416e-9cf7-dc0df0cd12d2.pdf
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.