GTR 93945403
Request For Quotation Fires (Sleeves, Hose Water Collector, Connective Head, Barrel, Column, Clamp)
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
93945403
Tendering Authority
Subscribe to view
Tender No
14268707
Financer Name
Self-Funded
Work Title
Request For Quotation Fires (Sleeves, Hose Water Collector, Connective Head, Barrel, Column, Clamp)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
18-03-2025
Closed
Work Detail
The Sleeve Of The Absorption Corrugated Class In -75 (Group 1) Gost 5398-76 (4 M+0.3-0.1M) With The Heads Of Gr-80 (2 Reinforced Clamps) Sleeve Absorbing Corrugated Class -75 Mm (4M+0.3-0.1 M) With Gr-80. The Sleeves Are A Pipeline Of Varying Degrees Of Flexibility (Depending On The Diameter), Made Of Rubber With A Textile Frame And Having A Metal Spiral Inside, Which Provides Sufficient Rigidity And Strength During Operation Under Various Conditions. At The Ends Of The Sleeves Are Soft Cuffs For Joining Reinforcement. Sleeve Design: 1. Internal Rubber Chamber 2. Textile Layer 3. Wire Spiral 4. Intermediate Rubber Layer 5. Textile Layer 6. Outive Textile Layer Of The Parameter: Vacuum - 0.08 Mpa And Pressure - At Least 0.3 And Not More Than 0.5 Mpa. It Can Be Operated In Regions With Moderate Conditions, Withstanding The Operating Temperature: 1. Temperature At Least - 35C Not More Than +90C. 2. Moderate Climate: At Least -35 No More Than +90 Degrees; 3. Tropical Climate: At Least -10 No More Than +90 Degrees; 4. Cold: At Least -50 No More Than +90 Degrees., Technical Specification For Pressure Fire Hoses With A Diameter Of 51 Mm, Pressure Fire Hoses With An Inner Diameter Of 51 Mm Are Designed For Supplying Water And Aqueous Solutions Of Foaming Agents. Pressure Fire Hoses Should Be Made In Accordance With The Requirements Of Article Rk 1714-2007 “Fire Technique. Fire Equipment. Sleeves Firefighters Pressure. Technical Fire Safety Requirements. Testing Methods ”And Other Regulatory Documents Or Technical Documentation For Fire Hoses Of A Particular Type Approved In The Prescribed Manner. Should Be Made With An Internal Waterproofing Layer And A Frame Impregnated With The Same Material As The Waterproofing Layer (Latex) As Well As Comply With Safety Requirements In Accordance With Gost 12.2.037. By The Type Of Climatic Performance, The “Uhl” Category According To Gost 15150 Must Correspond To The Configuration Of Mobile Fire Equipment And Designed To Work At An Environment Of At Least Parameters From Minus 50 C To Plus 45 S. The Pressure Fire Hoses Should Be No Earlier Than 2023 Years Of Manufacture. Technical Characteristics: Inner Diameter (Mm) 51 Sleeve Length, Not Less Than (M) 20 (± 1) Test Pressure, Not Less (Mpa) 2 Gap Pressure, Not Less Than (Mpa) 3.5 Sleeves 1 Meter Long, No More Than (Kg) 0.45 The Thickness Of The Internal Layer, Not Less (Mm) 0.35 Pressure Sleeves Should Be Put Up With Imposed (Icingly. With A Wire With A Diameter Of At Least 1.6 And Not More Than 1.8 Mm Gost 792), From Both Ends With The Connecting Heads Of The Gr-50 According To Gost 28352-89 “Connecting Heads For Fire Equipment. Types, Main Parameters And Sizes., Description Of The Suction Of A Fire Sleeve With A Diameter Of 125 Mm. The Sleeve Of The D-125 Suction With Gr-125 (Fixed With A Clamp) Sleeves Pressure Absorbing Gost 5398-76 With A Textile Frame And A Metal Spiral, Having At The Ends, Soft Cuffs To Join The Reinforcement. Designed For Technical Water. The Absorption Sleeve Is Designed For Water Intake From Open Sources Using Fire Pumps Or Pumps. Due To The Flexibility Of The Pipeline, The Use Of This Product Is Quite Wide. The Technical Requirements For Absorption Sleeves Are Almost Identical To The Pressure, With One Reservation - It Should Be Flexible Enough And At The Same Time Not To “Take Shape” When Creating Negative Pressure. They Have A Rigid Structure With Metal Spirals And A Textile Frame. They Are Operated At Ambient Temperature From -35 ° C To +90 ° C. The Length Of The Sleeve Is At Least 4 Meters., Technical Specification For Pressure Fire Hoses With A Diameter Of 66 Mm, Pressure Fire Hoses With An Internal Diameter Of 66 Mm Are Designed For Supplying Water And Aqueous Solutions Of Foaming Agents. Pressure Fire Hoses Should Be Made In Accordance With The Requirements Of Article Rk 1714-2007 “Fire Technique. Fire Equipment. Sleeves Firefighters Pressure. Technical Fire Safety Requirements. Testing Methods ”And Other Regulatory Documents Or Technical Documentation For Fire Hoses Of A Particular Type Approved In The Prescribed Manner. They Must Be Made With An Internal Waterproofing Layer And A Frame Impregnated With The Same Material As The Waterproofing Layer (Latex) As Well As Comply With Safety Requirements In Accordance With Gost 12.2.037. By The Type Of Climatic Performance, The “Uhl” Category According To Gost 15150 Must Correspond To The Configuration Of Mobile Fire Equipment And Designed To Work At An Environment Of At Least Parameters From Minus 50 C To Plus 45 S. The Pressure Fire Hoses Should Be No Earlier Than 2023 Years Of Manufacture. Technical Characteristics: Inner Diameter (Mm) 66 Sleeve Length, Not Less Than (M) 20 (± 1) Test Pressure, Not Less (Mpa) 2 Gap Pressure, Not Less (Mpa) 3.5 Sleeves 1 Meter Long, No More Than (Kg) 0.65 The Thickness Of The Internal Layer, Not Less (Mm) 0.35 Pressure Sleeves Should Be Put In A Set With Induced (Galvanized A Wire With A Diameter Of 1.6-1.8 Mm Gost 792), From Both Ends With The Connecting Heads Of The Gr-70 According To Gost 28352-89 “Connecting Heads For Fire Equipment. Types, Main Parameters And Sizes., The Hollow Water Carrier Vs-125 Dstu 2800-94 (Gost 14279-79) Is Designed To Collect Water From Two Fire Hoses And Its Supply To The Fire Pump. It Is Included In The Set Of Fire Engines. Technical Characteristics Of The Vs -125: The Conditional Passage Of The Output Pipe Of The Water Collector, Mm - 125 Conditional Passage Of Two Input Pipes, Mm - 80 Operating Pressure, Mpa - 1.0 Dimensions, Mm Length - 290 Width - 260 Mass, Kg - 3.6, The Fire Column Is A Removable Device Installed On An Underground Hydrant For Its Opening And Closing. The Column Consists Of Housing 8, Head 1 Cast From The Aluminum Alloy Al-6, And The End Key 3. A Bronze Ring 10 With A Thread For Installation On A Hydrant Is Installed In The Lower Part Of The Column Body. The Head Of The Column Has Two Pipe With A Coupling Connecting Heads For Connecting Fire Hoses. Opening And Closing The Pipe Is Carried Out By Valves, Which Consist Of Cover 5, Spindle 6, Plastic Valve 7, Flyrous 4 And Salted Stuffing Seal. The End Key Is A Tubular Bar, In The Lower Part Of Which A Square Coupling 9 Is Fixed To Rotate The Hydrant Bar. The Rotation Of The End Key Is Carried Out By Handle 2, Fixed At Its Upper End. The Seal Of The Place Of Exit Of The Bar In The Head Of The Column Is Ensured By A Stuffing Oil Seal. The Size Of The Column Is A Fire Conventional Passage, Mm 125 Working Pressure, Mpa 0.8 Conditional Passage Of The Connecting Head, Mm 80 Mass, Kg, Not More Than 18, The Delayed Insurance Penetration With A Heat -Resistant High -Strength Loop With A Case For Wearing A Belt Is Intended For Use For Asr For: Organizing A Person’S Insurance Or Self -Insurance Point At A Height; Use As A Sleeve Delay For Fixing At The Height Of The Pressure Sleeve; Fixations At The Height Of Equipment And Cargo. The Overall Dimensions Are In The Case, Mm: 160 X 130 X 50. The Length Of The Loop In A Folded State Is 0.75 M. The Mass In The Case Is 0.40 Kg. Technical Characteristics Of The Zr-80-A Hinge Delay, Designed For Sleeves With A Diameter Of At Least 80 Mm. Name Zr-80 Rope: 24 Strands, Diameter-8Mm Hook: Steel Mass: 300 Gr. Permissible Load: Not Less Than 1,1360 Kgf Loading Load: No More Than 3360 Kgf, The Firefighter Barrel Combined Rsk-50 Is Designed To Extinguish Fires With A Continuous And Sprayed (With A Variable Torch Angle) With A Stream Of Water. The Barrel Case Is Equipped With A Locking Device, Which Allows You To Adjust The Supply And Cessation Of Water Supply. The Firefighter Barrel Rsk-50 Is Attached To The Sleeve Due To The Connecting Head, Which Provides Rapid Lengthening Of The Hose Line If Necessary. Type Fire Inventory Color Silver Width, Cm 17 Length, At Least 56 Cm Max. Operation Temperature, At Least C ° 50 Type Of Fire Inventory Barrel, Fire Pressure Sleeve Rpm (B) -80-1.6-Uhl1 With An Internal Waterproofing Coating Without An External Protective Layer Of Rpm. The Cover Of The Sleeves Of The Sargian Weave From The High -Quality Polyester Thread. The Wool Layer Is The Savilen, The Thermoplastic Polymer Ethylene. The Sleeve Is Designed To Equip Fire Equipment In Order To Supply Water And Solutions Of The Foaming Agent To The Fire. Designed For Operating Pressure 1.6 Mpa. It Is Supplied In 2 Configuration Options: Without Reinforcement And With Heads. Technical Characteristics Conditional Passage (Dn) - 80 Internal Diameter, Mm - (77+2) Mass 1M, Kg, Not More Than - 0.65 Working Pressure, Mpa - 1.6 Test Pressure, Mpa, At Least - 2.0 Gap Pressure. Mpa, At Least - 3.5 Strength Of The Connection Of The Internal Layer Of The Coating With The Fabric Of The Frame, At Least - 10.0 Relative Lengthening Of The Sleeve At A Working Pressure, No More Than 5 Relative Increase In Diameter At A Working Pressure %, No More Than - 5 Range Of Operating Temperatures, ° C - 60/+40 Resistance To Abrasive Wear, Cycles, At Least 50, Transitional Head Gp-65X50 Alum. - Designed For A Durable And Sealed Connection Of Fire Hoses Of Different Diameters, As Well As For Connecting Sleeves With Fire Equipment Of A Different Diameter. Structurally Transitional Heads Consist Of Two Bushings With A Different Diameter Of The Conditional Passage, Connected By Thread And Two Clips. General Characteristics Type Of Head Transition (Gp) Material Aluminum Diameter Of The Compound 65X50 (Mm) Transition Diameter Of Conditional Passage 1.6 Mpa Mass 0.9 Kg, Fire Pressure Transition Head Gp-65 X 80 Mm To Connect Fire Equipment With Various Diameters, For Fire Engines, Fire Equipment, Nominal Diameters 65 X 80 Mm. General Characteristics Type Of The Head (Gp) Material Material Material Diameter Connection 65X80 (Mm) Conditioning Diameter 80 Mm Masses 0.3 Kg Detailed Configuration Of The Transition., Fire Pressure Transition Head Gp-50 X 80 Mm To Connect Fire Equipment With Various Diameters, For Fire Engines, Fire Equipment, Nominal Diameters 50 X 80 Mm General Characteristics Type Of Heads The Head Of The Head Of The Head Of Aluminum Diameter Of The Connection 50X80 (Mm) Transition, Tactical And Technical Characteristics Of The Clips Of Sleeve Clamps Exist Different Models:-Tape (Eliminates Ruptures Up To 3 Centimeters)-Karst Type (Used For Ruptures Or Cracks Up To 10 Cm) In The Fire Protection Units, The Zpr-80 Clip Of Fire Hose Zpr-80 Is Used For Pressure Fire Hoses With A Diameter Of 51, 66, 77 Mm. - The Place Of Damage Protected By A Clamp Is Not More Than 30 Millimeters. - The Mass Of The Device Is Not More Than 650 Grams.
Key Value
Tender Value
1,663,237 - KZT
Tender Documents
Global Tender Document
db755f51-237a-4f72-996d-7d721482db2f.html
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.