GTR 93904980

Request For Quotation Goods (Set Of Reagents, Reagents)

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
93904980
Tendering Authority
Subscribe to view
Tender No
14246404
Financer Name
Self-Funded
Work Title
Request For Quotation Goods (Set Of Reagents, Reagents)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
17-03-2025 Closed
Work Detail
Urea 500 Tests, Cassettes For The Analyzer Cobas Integra Urea/Urea Nitrogen For 500 Tests. Purpose: Set For In Vitro Diagnostics. Designed For The Quantitative Determination Of Urea/Nitrogen Urea In Serum, Plasma And Urine. Reagents And Working Solutions: R1 Nacl 9 % R2 Tris Bofer: 220 Mmol/L, Ph 8.6; 2 -Okoskglutarat: 73 Mmol/L; Nadn: 2.5 Mmol/L; Adf: 6.5 Mmol/L; Ureaase (Mucous Canal): ≥ 300 Μat/L; Gldg (Bull Liver): ≥ 80 Μat/L; Preservative; Unreactive R1 Stabilizers Are In Position C, R2 - In The Position Of V. Condition Of Storage And Transportation: Store In The Refrigerator. The Expiration Date At 2-8 ° C Cm Cm. When Used On Board The Analyzer At 10-15 ° C 8 Weeks. Transportation Is Mandatory In Thermal Containers With Refrigerated Elements At A Temperature Of 2-8 ° C, Not To Be Frozen And The Effects Of High Temperature. Calibration Is Linear At Two Points, The Frequency Of Calibration - After A Change In The Lot. Measurement Range 6.0-125 Μmol/L (33.5-700 Μg/Dl). The Lower Dough Detection Limit 6.0 Μmol/L (33.5 Μg/Dl). The Reproducibility Of The Test Is Not More Than 0.8 %. The Supplier Is Obliged To Provide A Certificate Of The Origin Of The Goods, The Deadline For Replacing Low-Quality And Inappropriate Goods: Within 3 Business Days. When The Goods Are Passed, The Presence Of A Representative Of The Supplier Is Mandatory. The Residual Expiration Date Of The Goods Is At Least 80% Of The Declared. St Rk Iso 9001-2016, Mission Reagent Test Strips For Urine Analysis 11A (150 Tests In Units), Albumin 300 Tests For A Biochemical Analyzer Cobas Integra Plus, Caliber Reagent For The Audicom Ac9801 Electrolytes Analyzer, Cleaner 1000Ml, A Cleansing Solution Is A Solution Of 1000 Ml To Clean The Sample And Sampling Of The Reagent And System For Intravenous Infusion. To Maintain The Integrity Of Samples Of The Sample And Reagent And System For Intravenous Infusion, Flushing Is Required. A Cleaning Solution Is Used As A Solution For Cleaning To Prevent Possible Transfer From The Sample And Sampling Of The Reagent And System For Intravenous Infusion. Reagents - Working Solutions Hcl 0.3 Mol/L. Storage And Transportation Conditions: Store At Room Temperature. The Shelf Life Of The Open Reagent In The Coolant For Reagents On Board The Analyzer Is 1 Week. Do Not Expose Mechanically, Do Not Freeze And The Effects Of High Temperature. The Supplier Is Obliged To Provide A Certificate Of The Origin Of The Goods, The Deadline For Replacing Low-Quality And Inappropriate Goods: Within 3 Business Days. When The Goods Are Passed, The Presence Of A Representative Of The Supplier Is Mandatory. The Residual Expiration Date Of The Goods Is At Least 80% Of The Declared. St Rk Iso 9001-2016, Bilirubin Total 250 Tests, Cassette Bilirubin Total Bilt (Bilirubin-Total Dpd) For 250 Tests. Purpose: In Vitro Test For The Quantitative Determination Of The Total Content Of Bilirubin In Serum And Blood Plasma (Adults And Newborn) On Roche/Hitachi Cobas C. Reagents And Working Solutions: R1 Phosphate: 50 Mmol/L; Detergents; Stabilizers; Ph 1.0 R2 3.5 -Dichlorophenil Diazonic Salt: ≥ 1.35 Mmol/L R1 Is In Position B And R2 - In Position C. Storage And Transportation Conditions: Store In The Refrigerator. The Expiration Date At 2-8 ° C Cm Cm. When Used On Board The Analyzer At 10-15 ° C 12 Weeks. Transportation Is Mandatory In Thermal Containers With Refrigerated Elements At A Temperature Of 2-8 ° C, Not To Be Frozen And The Effects Of High Temperature. Calibration Is Linear At Two Points, The Frequency Of Calibration - After A Change In The Lot. The Lower Dough Detection Limit Is 1.7 Μmol/L (0.999 Mg/Dl). The Reproducibility Of The Test Is Not More Than 0.6 %. The Hostage Is Obliged To Provide A Certificate Of Origin Of The Goods, The Deadline For Replacing Low -Quality And Inappropriate Goods: Within 3 Business Days. When The Goods Are Passed, The Presence Of A Representative Of The Supplier Is Mandatory. The Residual Expiration Date Of The Goods Is At Least 80% Of The Declared. St Rk Iso 9001-2016, Elecsys Ca 19-9 Calset For Immunochamiluminated Analyzer Cobas E-411, Elecsys Ca 72-4 Calset For Immunochamiluminestic Analyzer Cobas E-411, Creatin 700 Tests, Cassettes For The Cobas Integra Analyzer Creatin Creaj2 For 700 Tests. Purpose: Set For Diagnosis In Vitro. Designed For The Quantitative Determination Of Creatinine In Serum And Plasma Of Human Blood On Cobas Integra Analyzers Reagents And Working Solutions: R1 Potassium Hydroxide: 900 Mmol/L; Phosphate: 135 Mmol/L; Ph ≥ 13.5 Sr Picrinic Acid: 38 Mmol/L; Ph 6.5; The Unreactive Buffer R1 Is In Position B, Sr - In Position C. Storage And Transportation Conditions: Store At Room Temperature. The Shelf Life At 15-25 ° C Cm Cm. The Expiration Date On The Label Of The Cobas C Set. When Used On Board The Analyzer At 10-15 ° C 8 Weeks. Transportation Is Mandatory In Thermal Containers, Do Not Freeze And The Effects Of High Temperature. Calibration Is Linear At Two Points, The Calibration Frequency Is Each Cash Register, The Frequency Of Calibration Is 7 Days. Measurement Range 0.027-32.5 Mmol/L (0.31-367 Mg/Dl). The Lower Dough Detection Limit 0.027 Mmol/L (0.31 Mg/Dl). The Reproducibility Of The Test Is Not More Than 0.8 %. The Supplier Is Obliged To Provide A Certificate Of The Origin Of The Goods, The Deadline For Replacing Low-Quality And Inappropriate Goods: Within 3 Business Days. When The Goods Are Passed, The Presence Of A Representative Of The Supplier Is Mandatory. The Residual Expiration Date Of The Goods Is At Least 80% Of The Declared. St Rk Iso 9001-2016, Elecsys Anti-Hcv For Automatic Hemilyuminescent Analyzer Cobas E-411, Elecsys Calset Testosterone For Immunochamiluminated Analyzer Cobas E-411, Iron 200 Tests For Biochemical Analyzer Cobas Integra Plus, Elecsys Afp Calset Gen 2.1 For Automatic Hemiluminescent Analyzer Cobas E-411, Glucose 200 Tests, Gumza Cassette (Gluc Nk3) For 200 Tests. Purpose: In Vitro Test For The Quantitative Determination Of Glucose In Cerebrospinal Fluid, Urine, Serum And Blood Plasma On Roche/Hitachi Cobas C. Reagents And Working Solutions: R1 Tris Boofer: 100 Mmol/L, Ph 7.8; Mg2+: 4 Mmol/L; Atf: ≥ 1.7 Mmol/L; Nadf: ≥ 1.0 Mmol/L; Conservice R2 Hepes Bofer: 30 Mmol/L, Ph 7.0; Mg2+: 4 Mmol/L; Civil Code (Yeast): ≥ 130 Μat/L; G -6 -Ph (E. Coli): ≥ 250 Μat/L; The Preservative R1 Is In Position B, R2 - In Position C. Storage And Transportation Conditions: Store In The Refrigerator. The Expiration Date At 2-8 ° C Cm Cm. When Used On Board The Analyzer At 10-15 ° C 8 Weeks. Transportation Is Mandatory In Thermal Containers With Refrigerated Elements At A Temperature Of 2-8 ° C, Not To Be Frozen And The Effects Of High Temperature. Calibration Is Linear At Two Points, The Frequency Of Calibration - After A Change In The Lot. Measurement Range 0.11-40 Mmol/L (2-720 Mg/Dl). The Lower Dough Detection Limit 0.11 Mmol/L (2 Mg/Dl). The Reproduction Of The Test Is Not More Than 1.6 %. The Owner Is Obliged To Provide A Certificate Of Origin Of The Goods, The Deadline For Replacing Low -Quality And Inappropriate Goods: Within 3 Business Days. When The Goods Are Passed, The Presence Of A Representative Of The Supplier Is Mandatory. The Residual Expiration Date Of The Goods Is At Least 80% Of The Declared. St Rk Iso 9001-2016, Elecsys Ca 15-3 11 Calset For Immunochamiluminated Analyzer Cobas E-411, Bilirubin Straight 350 Tests, A Bilirubin Cassette Straight (Bilirubin-Direct) For 350 Tests. Purpose: In Vitro Test For The Quantitative Determination Of Direct Bilirubin In Human Serum And Plasma On Roche/Hitachi Cobas C. Reagents And Working Solutions: R1 Phosphoric Acid: 85 Mmol/L; Hedta: 4.0 Mmol/L; Nacl: 50 Mmol/L; Detergent; Ph 1.9 R2 3.5-Dichlorophenyldiazonium: 1.5 Mmol/L; Ph 1.3 R1 Is In Position B, And R2 Is In Position C. Storage And Transportation Conditions: Store In The Refrigerator. The Expiration Date At 2-8 ° C Cm Cm. When Used On Board The Analyzer At 10-15 ° C 12 Weeks. Transportation Is Mandatory In Thermal Containers With Refrigerated Elements At A Temperature Of 2-8 ° C, Not To Be Frozen And The Effects Of High Temperature. Calibration Is Linear At Two Points, The Frequency Of Calibration - After A Change In The Lot. The Lower Dough Detection Limit Is 1.2 Μmol/L (0.07 Mg/Dl). The Reproducibility Of The Test Is Not More Than 0.5 %. The Supplier Is Obliged To Provide A Certificate Of The Origin Of The Goods, The Deadline For Replacing Low-Quality And Inappropriate Goods: Within 3 Business Days. When The Goods Are Passed, The Presence Of A Representative Of The Supplier Is Mandatory. The Residual Expiration Date Of The Goods Is At Least 80% Of The Declared. St Rk Iso 9001-2016, Cleaner Cassette I11 150 Tests, A Cassette With A Cleansing Solution Of 150 Tests. A Purifying Solution Is A Solution For Cleaning The Sample And Sampling Of The Reagent And System For Intravenous Infusion. To Maintain The Integrity Of Samples Of The Sample And Reagent And System For Intravenous Infusion, Flushing Is Required. A Cleaning Solution Is Used As A Solution For Cleaning To Prevent Possible Transfer From The Sample And Sampling Of The Reagent And System For Intravenous Infusion. Reagents - Working Solutions Naoh 1 Mol/L. Storage And Transportation Conditions: Store At Room Temperature. The Shelf Life Of The Open Reagent In The Coolant For Reagents On Board The Analyzer Is 1 Week. Do Not Expose Mechanically, Do Not Freeze And The Effects Of High Temperature. The Supplier Is Obliged To Provide A Certificate Of The Origin Of The Goods, The Deadline For Replacing Low-Quality And Inappropriate Goods: Within 3 Business Days. When The Goods Are Passed, The Presence Of A Representative Of The Supplier Is Mandatory. The Residual Expiration Date Of The Goods Is At Least 80% Of The Declared. St Rk Iso 9001-2016, Cholesterol 400 Tests For A Biochemical Analyzer Cobas Integra Plus, Amylase Is Common For The Biochemical Analyzer Cobas Integra Plus, (Unit Of Measurement Test), Crp4 For A Biochemical Analyzer Cobas Integra Plus
Key Value
Tender Value
2,696,418 - KZT
Tender Documents
Global Tender Document
3ec60675-cbd8-4237-b907-08b88ea689c0.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders