GTR 93339531

Tenders Are Invited For Reagents And Consumables For The Modular Analyzer Cobas Pro (C 503) And Cobas Pure (C 303)

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
93339531
Tendering Authority
Subscribe to view
Tender No
14139933
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Reagents And Consumables For The Modular Analyzer Cobas Pro (C 503) And Cobas Pure (C 303)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
11-03-2025 Closed
Work Detail
Cassette Alkaline Phosphatase - Alkaline Phosphatase Acc. To Ifcc (Alp) 1100 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Alkaline Phosphatase For 1100 Tests. The Purpose Of The In-Vitro Test For The Quantitative Determination Of Alkaline Phosphatase In Serum And Human Plasma On Roche/Hitachi Cobas C Analyzers. Reagents - Working Solutions R12 -Amino -2 -Methyl -1 -Propanol: 1.724 Mol/L, Ph 10.44 (30 ° C); Magnesium Acetate: 3.83 Mmol/L; Sulfate Zinc: 0.766 Mmol/L; N- (2 -Hydroxyethyl) - Ethylendiamintrius Acid: 3.83 Mmol/L R2 P -Nitropenil Phosphate: 132.8 Mmol/L; Ph 8.50 (25 ° C); Preservatives. Storage And Stability Shelf Life At 2-8 ° C: See The Shelf Life On The Label Of The Cobas C Pack Cassette. The Shelf Life Of The Open Reagent In The Refrigerator On Board The Analyzer: 8 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette Alpha Amilase - Alpha -Amylase Eps (Amyl) 750 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Alpha Amilase At 750 Doughs. Purpose: Test For In Vitro Diagnostics. Designed For The Quantitative Determination Of The Catalytic Activity Of Α -Amilasis (1,4 -Α -D -Glucan: Glucanohydrolase; Ec 3.2.1.1) In Serum And Blood Plasma, As Well As Human Urine On Cobas C. Reagents - Working Solutions: R1 Hepes: 52.4 Mmol/L; Sodium Chloride: 87 Mmol/L; Calcium Chloride: 0.08 Mmol/L; Magnesium Chloride: 12.6 Mmol/L; Α -Glucosidase (Microbial): ≥ 66.8 Μat/L; Ph 7.0 (37 ° C); Detergent; Sr Hepes Stabilizers: 52.4 Mmol/L; Etiliden -G7 -Pnp: 22 Mmol/L; Ph 7.0 (37 ° C); Detergent; Stabilizers. The Reagent Is Ready For Use. Storage And Stability: The Shelf Life At 2-8 ° C. The Expiration Date Is The Expiration Date Of The Cobas C Cassethe Label. When Stored On Board The Analyzer At 10-15 ° C 12 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Alanin Aminotransferase Cassette - Alanine Aminotransferase Acc. To Ifcc Ii (Altp2) 800 Tests. Reagents For The Cobas Pro/Pure Analyzer. Alanin Aminotransferase Cassette For 800 Tests. Instally Of The Vitro Test For Quantitative Determination Of Aminotransferase Alanine (Alt) With Pyridoxfate Activation In Human Serum And Plasma In Roche/Hitachi Cobas C. Reagents - Working Solutions R1 Tris Boer: 224 Mmol/L, Ph 7.3 (37 ° C); L Alanin: 1120 Mmol/L; Albumin (Bull): 0.25 %; Laktathydrogenase (Bacterial): ≥ 45 Μat/L; Stabilizers; Conservice R2 Pyridoxalfosphate: 730 Μmol/L; Additives; Conservice R3 2 Oxoglutarate: 94 Mmol/L; Nadn: ≥ 1.7 Mmol/L; Additives; Conservice. The Storage Shelf Life At 2 8 ° C Is Ready To Use The Storage And Stability Of Altlp: See The Shelf Life Of The Cobas Cassette Label. The Shelf Life Of The Open Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Albumin Cassette - Albumin (Alb) 750 Tests. Reagents For The Cobas Pro/Pure Analyzer. Albumin Cassette For 750 Tests. Destination For In Vitro Diagnostics. Designed For The Quantitative Immunological Determination Of Human Albumin In Serum, Plasma, Urine And Smzh. Applications For Urine And Smzh Are Described In The Instructions For Tina -Quant Albumin Gen.2 Urine Application And Tina -Quant Albumin Gen.2 Csf Application. Reagents - Working Solutions R1 Trisa) Buer: 50 Mmol/L, Ph 8.0; Peg: ≥ 4.2 %; Edta: 2 Mmol/L; Conservative R2 Polyclonal Antibodies To The Albumin Of Human (Sheep): Depending On The Titer; Tris) Boofer: 100 Mmol/L, Ph 7.2; Conservice Sr Reagent To Check The Excess Antigen. Albumin In A Diluted Blood Serum (Humans); Phosphate Buffer: 50 Mmol/L, Ph 7.0; Conservative A) Tris = Tris (Hydroxymethyl)-Aminomethane R1 Is In Position A, R2 Is In Position B, And Sr Is In Position C. Ready For Use. Storage And Stability. The Expiration Date At 2-8 ° C. The Expiration Date Is The Expiration Date Of The Cobas C Cassethe Label. When Stored On Board The Analyzer At 10-15 ° C 12 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette Lactate Dehydrogenase - Lactate Dehydrogenase Acc. To Ifcc (Ldhi) 850 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Lactate Dehydrogenase For 850 Tests. Purpose Ph 9.4 (37 ° C); Lithium Lactate: 62 Mmol/L; Sr Stabilizers Above: 62 Mmol/L; Stabilizers; Conservatives. Hotages For Use. Storage And Stability. The Fitness At 2-8 ° C Is The Expiration Date Of The Expiration Date For Cobas C. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Glucose Cassette - Glucose Hk (Gluc Nk) 3300 Tests. Reagents For The Cobas Pro/Pure Analyzer. Glucose Cassette For 3300 Tests. Purpose: A Test For The Diagnosis In Vitro, Designed To Quantify Glucose In Serum, Plasma, Urine And Cerebrospinal Fluid On Cobas C Analyzers. Reagents - Working Solutions: R1 Buffer Of Morpholino -Eupo -Sulfonic Acid (Mes): 5.0 Mmol/L, Ph 6.0; Mg2+: 24 Mmol/L; Atf: ≥ 4.5 Mmol/L; Nadf+: ≥ 7.0 Mmol/L Sr Hepes Buffer: 200 Mmol/L, Ph 8.0; Mg2+: 4 Mmol/L; Civil Code (Yeast): ≥ 300 Μat/L; G6pdh (Bacterial): ≥ 300 Μat/L. Storage And Stability: Storage Period At 2-8 ° C. Cm Cm. Shelf Life On The Label Of The Cobas C Cassette. When Used On Board At 10-15 ° C 8 Weeks In The Case Of Non-Compliance Of The Product Specification For Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette For Determining The Aspartate Of Aminotransferase (Astp2) 800 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette For Determining The Aspartate Of Aminotransferase For 800 Tests. The Purpose Of The In Vitro Diagnostic Test For The Quantitative Determination Of Aspartateataminoresferase (Ast) In Serum And Blood Plasma On The Roche/Hitachi Cobas Activation With The Activation Of Pyridoxalphosphate. Reagents - Working Solutions R1 Tris Boer: 264 Mmol/L, Ph 7.8 (37 ° C); L Aspartat: 792 Mmol/L Mdg (Bacterial): ≥ 24 Μat/L; Ldh (Bacterial): ≥ 48 Μat/L; Albumin (Bull): 0.25 %; Conservice R2 Pyridoxalfosphate: 730 Μmol/L; Conservice R3 Napn (Yeast): ≥ 1.7 Mmol/L; 2 Okskoglutarat: 94 Mmol/L; Conservice. The Storage Shelf Life At 2 8 ° C Is Ready To Use The Storage And Stability Of The Astlp: See The Shelf Life On The Packaging Of The Cobas C Pack Cassette. The Shelf Life Of The Open Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Bilirubin Cassette General - Bilirubin Total (Bilt) 1050 Tests. Reagents For The Cobas Pro/Pure Analyzer. Bilirubin Cassette Is Common For 1050 Tests. Purpose: In Vitro Test For The Quantitative Determination Of The Total Content Of Bilirubin In Serum And Blood Plasma (Adults And Newborn) On Cobas C Analyzers. Reagents - Working Solutions: R1 Phosphate: 50 Mmol/L; Detergents; Stabilizers; Ph 1.0 Sr 3.5 -Dichlorophenil Diazonic Salt: ≥ 1.35 Mmol/L. The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 2-8 ° C See The Expiration Date For The Shelf Life On The Label Of The Cobas C. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette Creatinin Jaffa - Creatinine Jaffe (Crej) 2500 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Creatinin Jaffa For 2500 Tests. Purpose: A Test For The Diagnosis In Vitro, Designed To Quantitative Determination Of Creatinine In The Urine On The Analyzers Cobas C. Reagents - Working Solutions: R1 Potassium Hydroxide: 900 Mmol/L; Phosphate: 135 Mmol/L; Ph ≥ 13.5 Sr Picrinic Acid: 38 Mmol/L; Ph 6.5; Unrealistic Buffer. The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 15-25 ° C See The Date Of Expiration The Expiration Date On The Label Of The Cobas C. When Used On Board At 10-15 ° C 8 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Bilirubin Casket Direct - Bilirubin Direct (Bild) 1000 Tests. Reagents For The Cobas Pro/Pure Analyzer. Bilirubin Cassette Of A Straight Line For 1000 Tests. Purpose: In Vitro Test For The Quantitative Determination Of The Concentration Of Direct Bilirubin In Human Serum And Plasma On Cobas C. Reagents - Working Solutions: R1 Phosphoric Acid: 85 Mmol/L; Hedta: 4.0 Mmol/L; Nacl: 50 Mmol/L; Detergent; Ph 1.9 Sr 3.5 -Dichlorophenil Diazonius: 1.5 Mmol/L; Ph 1.3. The Reagent Is Ready For Use. Storage And Stability: Storage Period At 2-8 ° C. Cm Cm. Shelf Life On The Label Of The Cobas C Cassette. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette - Gamma -Glutamiltransferase - Gamma -Glutamyltransferase Standardized Against Ifcc/Szasz (Ggt) 400 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette - Gamma -Glutamiltransferase For 400 Tests. Appointment Test For Diagnosis In Vitro, Designed To Quantitatively Determine The Catalytic Activity Of The Ggtp (Ec 2.3.2.2; Γ -Lutamil Peptide: Amino Acid Γ -Lutamiltransferase) In Human Serum And Plasma On Cobas Integra. Reagents - Working Solutions R1 Tris: 492 Mmol/L, Ph 8.25; Glycillycin: 492 Mmol/L; Preservative; Addments Sr L -Umbutamil -3 -Carboxis - 4 -Nitroanilide: 22.5 Mmol.Gotov For Use. Storage And Stability. The Fitness Of The Suit Of 2-8 ° C. The Expiration Date Is The Expiration Date Of The Cobas C Cassethe Label. The Cobas Integra 400 Plus System During Storage On Board The Analyzer At 10-15 ° C 12 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette For Determining Iron - Iron 700 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette For Determining Iron For 700 Tests. Purpose: Test For In Vitro Diagnostics. Designed For Quantitative Determination Of Iron In Serum And Blood Plasma On Cobas C Systems. Reagents - Working Solutions: R1 Citric Acid: 200 Mmol/L; Tiomochevina: 115 Mmol/L; Unreactive Sr Sr Sodium Askorbat: 150 Mmol/L; Ferrozine: 6 Mmol/L; Conservice. The Reagent Is Ready For Use. Storage And Stability: The Expiration Date At 2-8 ° C. The Expiration Date Is The Expiration Date For Cobas C. When Stored On Board The Analyzer At 10-15 ° C 6 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Hemoglobin Cassette A1cx -Tina -Quant Hemoglobin A1cx 500 Tests. Reagents For The Cobas Pro/Pure Analyzer. Hemoglobin Cassette A1cx For 500 Tests. Purpose Of The In Vitro Test For Quantitative Determination Of Mmol/Mole Of Hemoglobin (Mfch) And % A1c Hemoglobin (Icdo/Npsg) In Solid Blood Or Hemolizate On Roche/Hitachi Cobas C. Definition Hba1c Concentrations Are Useful For Prolonged Monitoring Of Blood Glucose Levels In Patients With Diabetes. Moreover, This Test Is Used As An Aid In The Diagnosis And Detection Of Patients At Risk Of Diabetes. Reagents - Working Solutions - R1 Antibodies Reagent Mes Buffer: 0.025 Mol/L; Tris Bofer: 0.015 Mol/L, Ph 6.2; Hba1c Antibody (Sheep Serum): ≥ 0.5 Mg/Ml; Detergents, Stabilizers; Conservatives R3 Polygapteen Reagent Mes Buffer: 0.025 Mol/L; Tris Bofer: 0.015 Mol/L, Ph 6.2; Hba1c Polygapten: ≥ 8 M. The Reagent Is Ready For Use. Shelf Life At 2-8 ° C: See The Shelf Life On The Label Of The Cobas C Cassethe. The Shelf Life Of The Open Reagent In The Refrigerator On Board The Analyzer: 4 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Triglycerides Triglicirid Cassette (Trigl) 1000 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Trigglicirids For 1000 Tests. Purpose - In Vitro Test For The Quantitative Determination Of Triglycerides In Serum And Blood Plasma On Roche/Hitachi Cobas C Analyzers. Reagents - Working Solutions R1 Pipes-Boer: 50 Mmol/L, Ph 6.8; Mg2+: 40 Mmol/L; Sodium Hulat: 0.20 Mmol/L; Atp: ≥ 1.4 Mmol/L; 4 -Aminophenazone: ≥ 0.13 Mmol/L; 4 -Chlorophenol: 4.7 Mmol/L; Lipoproteinlipase (Pseudomonas Spec.): ≥ 83 Μat/L; Glycerokinase (Bacillus Stearothermophilus): ≥ 3 Μat/L; Glycerinphosphatexidase (E. Coli): ≥ 41 Μat/L; Peroxidase (Horseradish): ≥ 1.6 Μat/L; Preservative; Stabilizers R1 Are In Position B. Reagent Is Ready For Use. Shelf Life At 2-8 ° C: See Date Of Expiration Estability On The Label Of The Cobas C. The Shelf Life Of The Open Reagent In The Refrigerator On Board The Analyzer: 8 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Antibraptolisin Cassette - Antistreptolysin O (Aslo) 200 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Antibraptolizin For 200 Tests. Destination For In Vitro Diagnostics. Designed For Quantitative Determination Of Antibodies To Streptolizin O In Serum And Blood Plasma On Roche/Hitachi Cobas C. Reagents - Working Solutions R1 Tris Boer: 170 Mmol/L, Ph 8.2 R2 Boratial Buffer: 10 Mmol/L, Ph 8.2; Latex Particles Covered With Streptolizin O: 2 Ml/L. The Preparation Of The Working Solution Of The Reagent. Ready For Use. Before Installing The Cobas C To The Analyzer, Its Contents Mix Thoroughly. Before Use, Carefully Turn The Cassette With A Mixing Reagent Several Times. Storage And Stability Shelf Life At 2-8 ° C: See The Shelf Life On The Package Of Cobas C Pack Cassett. The Shelf Life Of The Open Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette For Determining The Rheumatoid Factor (Rf-Ii) 400 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette For Determining The Rheumatoid Factor For 400 Tests. Set A Set For In Vitro Diagnostics. Designed For The Quantitative Determination Of The Rheumatoid Factor (Rf -Ii) In Serum And Blood Plasma On Roche/Hitachi Cobas C. Measurements Can Be Used As Assistance In The Diagnosis Of Rheumatoid Arthritis. Reagents - Working Solutions R1 Glycine Buffer: 170 Mmol/L, Ph 8.0; Polyethylene Glycol: 0.05 %; Albumin Serum Of Bull Blood; Stabilizer; Preservative R2 Latex Particles Covered With Igg Person; Glycine Buffer Solution: 170 Mmol/L, Ph 7.3; Stabilizers, Preservatives R1 Are In Position B, R2 - In The Position Of C. Reagent Is Ready For Use. Preservation And Stability Rf -Ii Shelf Life At 2-8 ° C: See Shelf Life On The Label Of The Cobas C. The Shelf Life Of The Open Reagent In The Refrigerator On Board The Analyzer: 8 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette General Protein - Total Protein (Tp) 650 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Total Protein For 650 Tests. Purpose: Test For In Vitro Diagnostics. Designed For The Quantitative Determination Of The Concentration Of Total Protein In Serum And Blood Plasma On Cobas C Systems. Reagents - Working Solutions: R1 Sodium Hydroxide: 400 Mmol/L; Vinin -Acidic Kaliynatriy: 89 Mmol/L; Ph: 13.4 Sr Sodium Hydroxide: 400 Mmol/L; Vinin -Acidic Kaliynatriy: 89 Mmol/L; Iodid Potassium: 61 Mmol/L; Sulfate Copper: 24.3 Mmol/L; Ph: 13.2. The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 15-25 ° C. See The Expiration Date On The Label Of The Cobas C Cassette. When Used On Board The Analyzer At 10-15 ° C 4 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., C-Reactive Protein Cassette-C-Raactive Protein (Crp) 500 Tests. Reagents For The Cobas Pro/Pure Analyzer. C-Reactive Protein Cassette For 500 Tests. Purpose: Immuniurbidimetric Test For The Quantitative In Vitro Determination Of C -Reactive Protein (Crp) In Human Serum And Plasma Using The Cobas S. Reagents - Working Solutions: R1 Buffer Solution Tris) With Albumin Serum Of Bull Blood; Sr Preservatives Of Latex Particles Covered With Anti -Crp (Mouse) In A Glycine Buffer; Immunoglobulins (Mice); Conservice. The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 2-8 ° C. Cm Cm. The Expiration Date For The Shelf Life On The Label Of The Cobas C. When Used On Board The Analyzer At 10-15 ° C 12 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette For Determining Unsaturated Iron -Binding Ability - Unsaturated Ironbinding Capacy (Uibs) 100 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette For Determining Unsaturated Iron -Binding Ability Per 100 Tests. Purpose: In Vitro Test For The Quantitative Determination Of Unsaturated Iron -Binding Ability Of Blood Serum And Human Plasma. Reagents And Working Solutions: R1 Iron Chloride: 62 Μmol/L; Sodium Bicarbonate: 75 Mmol/L; Tris Bofer: 375 Mmol/L, Ph 8.4; Conservice R3 Ferrozin: 20 Mmol/L; Hydoxylamine: 160 Mmol/L, Ph 2.5 R1 Is In Position A, And R3 - In S. Position, The Position B Contains H2o For Technical Reasons. Storage And Transportation Conditions: Store In The Refrigerator. The Expiration Date At 2-8 ° C Cm Cm. When Used On Board The Analyzer At 10-15 ° C 8 Weeks. Transportation Is Mandatory In Thermal Containers With Refrigerated Elements At A Temperature Of 2-8 ° C, Not To Be Frozen And The Effects Of High Temperature. Calibration Is Linear At Two Points, The Frequency Of Calibration - After A Change In The Lot. Measurement Range 6.0-125 Μmol/L (33.5-700 Μg/Dl). The Lower Dough Detection Limit 6.0 Μmol/L (33.5 Μg/Dl). The Reproducibility Of The Test Is Not More Than 0.8 %. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. The Presence Of A Document Confirming The Supply To A Potential Supplier Having The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Mochevin Cassette - Urea/Bun (Ureal) 600 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Of Urea For 600 Tests. Purpose: Test For In Vitro Diagnostics. Designed For Quantitative Determining The Concentration Of Urea/Bun (Nitrogen Of Urea Of ​​The Blood) In Serum And Blood Plasma And In Human Urine On Cobas C Analyzers. Reagents-Working Solutions: R1 Tris Boofer: 220 Mmol/L; 2 -Oxoglutarate: 73 Mmol/L; Nadh: 2.5 Mmol/L; Adf: 6.5 Mmol/L; Ureaase (Mucous Canal): ≥ 300 Μat/L; Gldh (Bull): ≥ 80 Μat/L; Stabilizers; Ph 8.6. The Reagent Is Ready For Use. Storage And Stability: The Shelf Life At 2-8 ° C. The Expiration Date Is The Expiration Date Of The Cobas C Cassethe Label. When Stored On Board The Analyzer At 10-15 ° C 8 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette Ldl Cholesterol - Ldl -Cholesterol (Ldlc) 600 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Ldl Cholesterol For 600 Tests. Purpose Of The Test For In Vitro Diagnostics. Designed For The Quantitative Determination Of Ldl Cholesterol In Serum And Blood Plasma On Roche/Hitachi Cobas C. Reagents - Working Solutions R1 Bis -Trasb) Boofer: 20.1 Mmol/L, Ph 7.0; 4 -Aminoantipirin: 0.98 Mmol/L; Ascorbatexidase (Aod, Acremonium Spec.): ≥ 66.7 Μat/L; Peroxidase (Recombinant From The Basidiomycet): ≥ 166.7 Μat/L; Bsa: 4.0 G/L; Conservice R2 Mopsc) Boofer: 20.1 Mmol/L, Ph 7.0; Emse: 2.16 Mmol/L; Cholesterineesturaza (Pseudomonades): ≥ 33.3 Μat/L; Cholesterinsidase (Recombinant From E. Coli): ≥ 31.7 Μat/L; Peroxidase (Recombinant From The Basidiomycet): ≥ 333.3 Μat/L; Bsa: 4.0 G/L; Detergents; Conservice. The Reagent Is Ready For Use. The Shelf Life At 2-8 ° C: See The Shelf Life On The Label Of The Cobas C. C In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Hdl Cholesterol Cassette - Hdl -Cholesterol (Hdlc) 700 Tests. Reagents For The Cobas Pro/Pure Analyzer. Hdl Cassette Cholesterol For 700 Tests. The Purpose Of In Vitro Test For The Quantitative Determination Of Cholesterol -Cvp In Serum And Blood Plasma On Roche/Hitachi Cobas C Analyzers. Reagents - Working Solutions R1 Tapsob) Boofer: 62.1 Mmol/L, Ph 7.77; Polyanion: 1.25 G/L; Emse: 1.08 Mmol/L; Ascorbate Oxidase (Pumpkins): ≥ 50 Μat/L; Peroxidase (Horseradish): ≥ 166.7 Μat/L; Detergent; Bsa: 2.0 G/L; Conservice R2 Bis Tricc) Boofer: 20.1 Mmol/L, Ph 6.70; Cholesterin-Austerase (Microorganism): ≥ 7.5 Μat/L; Cholesterol-Oxidase (Recombinant E. Coli): ≥ 7.17 Μat/L; Cholesterol-Oxidase (Microorganism): ≥ 76.7 Μtat/L; Peroxidase (Horseradish): ≥ 333 Μat/L; 4 -Amino -Antipirin: 1.48 Mmol/L; Bsa: 3.0 G/L; Detergents; Conservation. Ready For Use. Shelf Life At 2-8 ° C: See Shelf Life For Cobas Cobas Cobas Cassethe Label. The Shelf Life Of The Open Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base., Cassette Phosphate - Phosphate (Inorganic) (Phos) 750 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Phosphate For 750 Tests. Destination For In Vitro Diagnostics. Designed For The Quantitative Determination Of Phosphorus In Serum, Plasma And Urine On Roche/Hitachi Cobas C. Reagents - Working Solutions R1 Sulfuric Acid: 0.36 Mol/L; Detergent R2 Molibdat Ammonium: 3.5 Mmol/L; Sulfuric Acid: 0.36 Mol/L; Sodium Chloride: 150 Mmol/L. Ready For Use. Storage And Stability. Shelf Life At 2-8 ° C: See The Shelf Life On The Label Of The Cobas C Cassette. The Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. In The Case Of Non-Compliance Of The Product Specification, Replacing The Goods Within 3 Days After Notification. Identification Of The Reagent Using Rfid Chip. Each Bottle Should Have Rfid Label With Encoding Information. Before Supplying The Reagent, Update The Analyzer Reagents Base.
Key Value
Tender Value
1,997,387 - KZT
Tender Documents
Global Tender Document
ba7c5477-947a-4e26-8463-bfb9f02aa452.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders