GTR 92911051
Tenders Are Invited For Architectural, Construction, Engineering And Inspection Services-Object Planning Lph 6-9: Retrofitting Fall Protection, Upgrading Sekuranten, Coord. Construction Pv System, Construction Of Refrigeration Systems For Server Room Cooling
ICB — International Competitive Bid
Closed
Western Europe
Tender Information
GTR Reference
92911051
Tendering Authority
Subscribe to view
Tender No
115942-2025
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Architectural, Construction, Engineering And Inspection Services-Object Planning Lph 6-9: Retrofitting Fall Protection, Upgrading Sekuranten, Coord. Construction Pv System, Construction Of Refrigeration Systems For Server Room Cooling
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Western Europe
Political Region
European Union,G20
Last Date of Bid Submission
25-03-2025
Closed
Work Detail
Architectural, Construction, Engineering And Inspection Services-Object Planning Lph 6-9: Retrofitting Fall Protection, Upgrading Sekuranten, Coord. Construction Pv System, Construction Of Refrigeration Systems For Server Room Cooling. Object Planning Building According To Par. 34 Hoai Retrofitting Of Fall Protection On The Flat Roofs Bt 1-5, Upgrading Sekuranten System On The Bt 6 And 7, Lph 6-9 And Coordination Construction Pv Systems For The Following Construction Projects: Vocational School Center 30-44, Photovoltaic Systems And Fall Fuses. Pv Modules Are Set Up On Components 1 To 5 As Part Of This Measure Over The Existing Green Roof. The Location Of The Inverters With Weather Protection Roofs Is On The Roofs Over The Elt Rooms. The Feed -In With Counting Takes Place In The Electrical Engineering Rooms In The 3Rd Floor. - Since The Existing Security Systems (Rope System) No Longer Meet Todays Requirements And The Pv Modules, As Well As The Ventilation Systems And The Green Roof On The Roofs, Have To Be Waited For, Fall Protection Is Assembled On The Roof Edges According To The Requirements Of The Workshop Ordinance. To Do This, The Existing Roof Structure Must Be Removed And Restored On The Edges, The Attica Increases And Additionally Anchored And Retained. The Railing Is Constructed As A Stick Railing With Upper, Medium And Lower Belt And Attached To The Reinforced Attica. In The Course Of The Measure, The Roof Drainage Systems Of Components 1 To 5 Were Redesigned. The Drainage Pipes In The Building Continue To Be Sufficient For Drainage. In The Courtyards, Some Basic Pipes Must Be Enlarged To The Existing Seepage Systems. Earth And Landscaping Work Is Also Required. Due To The Redesign, Additional Necessary Emergency Drainage On Components 1 To 5 Is Planned. No Extensive Changes (Sports Hall/ Cafeteria) Are Planned On Components 6 And 7. Therefore, The Client Has Decided Not To Check The Drainage Systems Here. On These Two Roofs, Only The Safety Ropes Are Supplemented To The Roof Clips. Since The Existing Deep Wells Can No Longer Do The Cooling Capacity Of The Server Cooling, Refrigeration Systems For Server Room Cooling Must Be Built. Corresponding Specialist Planners Have Already Been Switched On.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
11e83750-bde1-435f-b9f7-40e121b04ee6.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.