Bids Are Invited For Hiring A Specialized Company To Supply Permanent Equipment And Materials To Compose Ambulance Vehicles To Serve The Mobile Emergency Care Service - Samu, In Charge Of The Municipal Health Secretariat
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
92735798
Tendering Authority
Subscribe to view
Tender No
005/2025
Financer Name
Self-Funded
Work Title
Bids Are Invited For Hiring A Specialized Company To Supply Permanent Equipment And Materials To Compose Ambulance Vehicles To Serve The Mobile Emergency Care Service - Samu, In Charge Of The Municipal Health Secretariat
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
20-02-2025
Closed
Work Detail
Defibrillator/ Cardioverter/ Minimal Technical Characteristics: 1. Adapter Cable For Disposable Electrode.2. When A Shock Pace Is Detected, The Defibrillage User Guidelines Through. Manual Desfibrillator 1. Load Time: 0 To 200J Emmenos Of 4 Seconds; 0 To 270J Emmenos Of 5 Seconds; 2. After Defibrillation, The Ecg Deonda Shape Recovers Within 3Seconds, So That It Is Possible To Immediately Verify The Resulting Deribrillation; 3. Output Energy (Through 50): 2, 3, 5, 7, 10, 15, 20, 30, 50, 70, 100, 150, 200 And 270 J; 4. Energy Limit: 50 J For The Pages; 5. Output Waveform: Truncated Biphasic Biphasicial; 6. Load Presentation: Presentation Of Energy Charged On Screen; 7. Load Status Indication: A Loaded Status Som Is Issued After The Load Is Complete; 8. Synchronized Discharge: Available; 9. Internal Automatic Discharge: Stored Aenergy Is Unloaded In The Following Cases: A. Power Selector Is Configured As “Disarm” B. Energy Is Off. Shoot Connector Is Disconnected From The Main Unit. Pre-Configured Period From After The Load Is Complete. Disposable Electrodes Are Patient From The Patient.Monitor1. Display: 6, 5 Inches, Colored Lcd; 2. Effective Presentation Area: 132, 48 X 99, 36 Mm; 3. Number Of Curves: 3 (Ecg, Spo₂, Co₂); 4. Heart Frequency (Fc) Between 15 A300 Bpm; 5. Scanning Velocity: 25 Or 50Mm/S (Ecg, Pulse), 6, 25 Or 12, 5Mm/S (Co2) 6. Ecg Amplitude: X1/4, X1/2, X1, X2, X4, Auto; 7. Medicines: Inclusion Demedications Applied During Patient Resuscitation Process 8. Freezing Curve In Modomonitor; 9. Alphanumeric Display :Cardiac Frequency, Spo2 (%), Depulsive Frequency, Co2, Breathing10. Ecg Derivation: Pá, I, Ii, Iii, Avr*1, Avl*1, Avf*1, V (One From V1 To V6)*1, Aux, Test*2A. *1: With 6 Via Connection Cable. *2: With Load, Infusion Pump: Minimum Technical Characteristics: High Precision Infusion Control, Compatible With Most Iv Compatibles. Remembering The Beginning Of Infusion And Display Of Timely. Air Bubble Alarm Threshold And The Pressure Can Be Adjusted And The Alarm Volume Is Also Adjustable. Accompanying Ivdefine The Staple Prevents Liquid Free Discharge If The Pump Opens Accidentally. A.B.S-Anti Bolus System Prevents An Injection To The High Dose Of Sudden To Disappear. (Except For Nearend, Kvo And Low Batterylarmes). Aluminocompact And Robust Boxes. Chinese And English Are Optional. Usb Port Is Confvenient For Technical People To Update The Software. The Versatile Support Allows The Infusion Of The Pole Infusion In Many Directions, Which Can Save Money. Specifications: • Dounsual Manual • Power Cable • System: Linear Peristaltic • Compatible With Universal Equiples Suitable For Infusion Pump, Silicone Abase • Vazan Deviation Of The Standard Silicone Standard: ± 5%Flow After Calibration (*); • Rate Of Infusion: 1-699Ml / H, Increment: 1Ml / H; • Total Volume: 1-9999Ml / H, Increment: 1 Ml / H; • Deoclusion Pressure: 100 Kpa ~ 300Kpa; • Kvo: Below 5Ml/H Kvo Of 1Ml/H And 5Ml/H Kvo 5Ml/H • Bolus: Fixed At 699 Ml/H; • Air Bubbles Detector: Ultrasound; • 3, 5 Inch Displaylcd; • Alarm: Byoclusion, Infusion Close To The End, Air Bubbles, Open Door, Engine Failure, Finalizing Perfusion, Warning Warning, Kvo State, Weak Battery, Power Failure, Pressure Failure, Door Failure And Absence
Key Value
Tender Value
41,839 - BRL
Tender Documents
Global Tender Document
5244bc08-d985-4af7-bfa0-3d6760d7bfe3.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.