GTR 92451123

Bids Are Invited For Pulmonary And Bipap Fan Acquisition

ICB — International Competitive Bid Closed South America
Tender Information
GTR Reference
92451123
Tendering Authority
Subscribe to view
Tender No
119/2025
Financer Name
Self-Funded
Work Title
Bids Are Invited For Pulmonary And Bipap Fan Acquisition
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
24-02-2025 Closed
Work Detail
(L1) 6515.12895-Pulmonary Ventilator, Microprocessed Electronic Fan For Pediatric Neonatal Patients And Morbid Obesity, Suitable For Use In Intensive Care, With At Least The Following Ventilation Modes: Voel Volume Vertilation (Assisted / Controlled, Simv) ; Pcv Controlled Pressure Ventilation (Assisted / Controlled, Simv); Controlled Pressure Ventilation, Bipap Or Bi-Physical, Which Allows Spontaneous Ventilation (Active Expiratory Valve); Non -Invasive Ventilation - Niv; Ventilation In Invasive And Noninvasive Cpap, Psv Ventilation With The Possibility Of Supporting Support Cycling Of The Support Pressure, Parameters: Fi2 From 21 To 100%; Middle Volume Should Enable Adjustment From 10 Ml To At Least 2000Ml; Respiratory Rate From 5 To 150 Rpm; Inspiratory Time From 0, 2 To 5 Seconds At Least; 5 To 70% Supporting Pressure Cycling Of Inspiratory Flow Peak; Inspiratory Pressure From 5 To 80 Cmh2o. Support Pressure From 5 To 70Cmh2o At Least. These Pressure Values ​​Cannot Be Considered With Peep, Ie They Must Be Considered Individually; Peep From 0 To 50 Cmh2o At Least; Have Inspiratory Sensitivity By Flow And/Or Pressure Sensitivity; Have Adjustable Rise Time (Rise Time) Or Inspiratory Time Control On All Pressure -Controlled Modalities; Monitoring System: At Least 12 ”Colored Screen With Touch -To -Touch Drive For Ease Of Operation And Possibility Of Slope, Rotational Button For Selection, Adjustment And Confirmation Of The Parameters. Presentation Of Curves Pressure X Time, Flow X Time, Volume X Time And Loops Pressure X Volume (Presentation Of At Least Three Curves Simultaneously In Real Time); The Equipment Must Have Numerical Values ​​Of The Main Ventilatory Parameters; The Equipment Will Not Be Able To Monitor Any Parameter Through Proximal Sensors To The Patient (In Y), Except For Neonatal Patients, Where The Equipment Can Work With This Tip, (L2) 6514.60721-Breathing For Intermittent Positive Pressure, Other Information According To With Term Of Reference And/Or Technical Descriptive Of The Process, Unid. Measurement: Unit
Key Value
Tender Value
1,384,378 - BRL
Tender Documents
Global Tender Document
80d623f1-c8cc-4eaa-bda0-fff7cecca3c8.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders