GTR 89843962

Request For Quotation Purchase Of Honey Products

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
89843962
Tendering Authority
Subscribe to view
Tender No
13487873
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Honey Products
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
15-12-2024 Closed
Work Detail
Stromatolyser-Wh Lysing Solution 3 X 500 Ml From A Set Automatic Hematological Analyzer Xp-300 (3X500 Ml) Stromatolyzer-Wh Solution From A Set For Sysmex Xp300 Analyzer. Packaging Of The Reagent Is No More Than 0.5 L X 3 Bottles. The Package Must Have A Bar Code For Entering Data Into The Analyzer Software. Closed System. Reagent Composition: Organic Quaternary Chlorides And Ammonium 8.5G/L Sodium Chloride 0.6G/L Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer. Consumer Packaging Must Be Equipped With A Barcode Containing All The Information About The Reagent Necessary For The Analyzer To Work., Alpha-Amylase Eps Ba400 2X60ml+2X15ml Alpha-Amylase Set Of Biochemical Reagents From The Set Biochemical Analyzer - Turbidimetric Ba400 Closed System. The Presence Of A Barcode On Each Vial, Pancreatic Profile, 4-Nfmh, Immunoinhibition, Liquid Bireagent. Composition: Reagent A. Hepes 50 Mmol/L, Calcium Chloride 0.075 Mmol/L, Sodium Chloride 90 Mmol/L, Magnesium Chloride 13 Mmol/L, Α-Glucosidase > 4 U/Ml, Monoclonal Antibodies (Mouse) 50 Mg/L, Ph 7.1. Reagent B. Hepes 50 Mmol/L, 4-Nitrophenyl-Maltoheptaoside-Ethylidene 18 Mmol/L, Ph 7.1. Metrological Characteristics: Threshold Sensitivity: 4.30 Ed/L = 0.072 Μkat/L. Limits Of Linearity: 1300 Ed/L = 21.6 Μkat/L. Accuracy: Serum. The Average Concentration Is 66 U/L = 1.10 Μcat/L. Repeatability (Cv) - 1.5%, Intralaboratory Index (Cv) - 1.7%; Average Concentration: 149 Ed/L = 2.47 Μkat/L. Repeatability (Cv) 1.4%, Intralaboratory Index (Cv) - 1.4%. Accuracy: Urine. The Average Concentration Is 62 U/L = 1.03 Μcat/L. Repeatability (Cv) - 2.1%, Intralaboratory Index (Cv) - 2.5%; Average Concentration: 124 Ed/L = 2.06 Μkat/L. Repeatability (Cv) 1.3%, Intralaboratory Index (Cv) - 1.9%. Number Of Studies - 450, Packaging 2X60ml+2X15ml, T+2 +8 C. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer, Glucose From A Set Biochemical-Turbidimetric Analyzer Va400 (10X60ml) Glucose A Set Of Biochemical Reagents From A Set Biochemical-Turbidimetric Analyzer Ba400 Closed System, Barcode On Each Bottle. Diabetic Profile; Glucooxidase, End Point; Liquid Monoreagent. Composition: Reagent A. Phosphate 100 Mmol/L, Phenol 5 Mmol/L, Glucose Oxidase > 10 Units/Ml, Peroxidase > 1 Unit/Ml, 4-Aminoantipyrine 0.4 Mmol/L, Ph 7.5. Metrological Characteristics: Limit Of Detection: 2.8 Mg/Dl = 0.155 Mmol/L. Limit Of Linearity: 500 Mg/Dl = 27.5 Mmol/L. Accuracy: Average Concentration: 88 Mg/Dl = 4.90 Mmol/L. Repeatability (Cv): 1.0%. Intralaboratory Indicator (Cv): 1.7%. Average Concentration: 220 Mg/Dl = 12.2 Mmol/L. Repeatability (Cv): 0.4%. Intralaboratory Index (Cv): 1.1%. The Number Of Studies Is 1,800. Packaging 10X 60 Ml, T+2 +8 C. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer., Test Strips Uriscan 11 St 100 Tests Test Strips Uriscan 11 Strip Urine Analyzers. For The Diagnosis Of The Following Parameters: Erythrocytes, Bilirubin, Urobilinogen, Ketone Bodies, Nitrites, Protein, Glucose, Leukocytes, Specific Gravity, Ascorbic Acid, Ph., C-Reactive Protein Ba400 1X60+1X15 Ml C-Reactive Protein Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Analyzer Ba400, Produced By The Company Biosystems S.A (Spain), Closed System, Presence Of A Barcode On Each Bottle. Inflammatory Profile; Latex Agglutination/Antibodies To Crp, Fixed Time; Liquid Bireagent. Composition: Reagent A. Glycine Buffer 0.1 Mol/L, Sodium Azide 0.95 G/L, Ph 8.6. Reagent B. Suspension Of Latex Particles Covered With Antibodies To Human Crp, Sodium Azide 0.95 G/L. Metrological Characteristics: Threshold Sensitivity: 1.9 Mg/L. Limits Of Linearity: 150 Mg/L. Accuracy: Average Concentration 14 Mg/L. Repeatability (Cv) - 2.9%, Intralaboratory Index (Cv) - 4.9%; The Average Concentration Is 43 Mg/L. Repeatability (Cv) -1.5 %. The Total Error (Cv) Is 2.6%. Number Of Studies - 225. Packaging 1X60ml+1X15ml, Storage Temperature +2 +8 ⁰С. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. Reagents Must Be Recommended For Use By The Manufacturer Of Ba200/Ba400 Analyzers., Cellclean (Cellclean Cleaning Solution) From The Set Automatic Hematological Analyzer Of The Xn-L Series, Models Xn-350, Xn-450, Xn-550 (50 Ml) Cellclean Solution From The Set For The Sysmex Xp300 Analyzer, No More Than 50 Ml/Pack. Closed System. The Package Must Have A Bar Code For Entering Data Into The Analyzers Software. Sodium Hypochlorite (5.0% Available Chlorine Concentration) Will Provide Authorization From The Equipment Manufacturer. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer. Consumer Packaging Must Be Equipped With A Barcode Containing All The Information About The Reagent Necessary For The Analyzer To Work., Paper Чл 57 Mm, Thermal Paper Roll Paper For A Thermal Printer
Key Value
Tender Value
1,839,052 - KZT
Tender Documents
Global Tender Document
188de195-97c4-48e7-983e-ed49d0f088b8.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders