GTR 89803747
Bids Are Invited For Aq. Permamental Equipment / Mab
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
89803747
Tendering Authority
Subscribe to view
Tender No
007/2024
Financer Name
Self-Funded
Work Title
Bids Are Invited For Aq. Permamental Equipment / Mab
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
11-12-2024
Closed
Work Detail
(Id124837) Multiparametric Monitor, Application: Adult, Pediatric And Neonatal Use; Presentation: Lcd/Led Min 14Pol, Touchscreen, Min:1024X768; Modular; Monitoring: Ecg, Spo2, Resp, Temp, Non-Invasive Pressure (Pni), Invasive Blood Pressure (Pi), Cardiac Output (Co) And Etco2 (Capnography); Simultaneous Visualization Min: 6 (Six) Curves, With Numerical Values; Audible And Visual Alarm System, With Programmable Max And Min Limits; Automatic Screen Reconfiguration; Patient Data Record; Thermal Recorder; Possibility Of Central Monitoring Connection; Hl7; Sw In Portuguese; Ecg: Monitoring: 07 Leads (I, Ii, Iii, Avf, Avr, Avl, V); Freq. Cardiac (Hr): 15250Bpm; St Segment Analysis: All Derivations; Analysis Of Fatal Arrhythmias In Two Simultaneous Channels, At Minimum (Optional); Analyze Arrhythmias (Asystole, Ventricular Fibrillation/Ventricular Tachycardia, Bigeminism, Among Others); Automatic Pacemaker Detection; Breathing: Respiratory Freq (Fr) Min: 6150Rpm; Adjust Apnea Alarm. Pulse Oximetry (Spo2): Technology: Low Perfusion; Present Plethysmographic Curve; Spo2 Saturation Range: 1100%; Pulse Frequency (Fp): 40250Bpm; Pni: Systolic, Diastolic And Mean Blood Pressure; Measurement Modes: Manual, Automatic And Stat; Pressure Measurement: 30270Mmhg; Temperature: 02(Two) Channels; Measurement: Superficial And Esophageal Sensor; Temp Range: 2545°C; Capnography (Etco2): Sidestream Or Mainstream Technology, Sampling: 50Ml/Min, Co2 Measurement: 099Mmhg; Pi: 02 Channels, Pi Measurement: 30 To 300Mmhg, Accuracy: ±1Mmhg Or ±3%, Whichever Is Greater; Have A Physiological And Technical Alarm; Measure Pressures: Pulmonary Artery, Right Atrium, Central Venous, Left Atrium, Intracranial; Arterial, P1 And P2; Cardiac Output (Co): 0, 120 L/Min; Pulse Pressure Variation Vpp (Or Delta Pp); Specific Cva Screen (Oxycardiorespirogram) For Cardiorespiratory Disorders; Trends: Minimum Storage Of 24H Non-Volatile; Network And/Or Battery Indicator; Rechargeable Battery: Minimum Autonomy: 90 Min; Ac Automa Power Supply, (Id134685) Phototherapy Device, Application: Neonatal Jaundice; Type: Luminous Spotlight; Stem; Pedestal; Base With Caster; Lighting: Led; Light Emission: Blue; Unit With Microprocessor Control Panel With Irradiance Adjustment; Power: 127/220V (50/60Hz). .Additional Information: Carry Out A Technical Visit For Compatible Brands And Models In The Unit. May Contradict The Item Description (Id134685), 12/09/2024
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
62079e72-a43e-43a4-977c-222425e01ca1.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.