GTR 89457907
Request For Quotation Purchase Of Honey Products
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
89457907
Tendering Authority
Subscribe to view
Tender No
13460253
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Honey Products
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
10-12-2024
Closed
Work Detail
Stromatolyser-Wh Lysing Solution 3 X 500 Ml From A Set Automatic Hematological Analyzer Xp-300 (3X500 Ml) Stromatolyzer-Wh Solution From A Set For Sysmex Xp300 Analyzer. Packaging Of The Reagent Is No More Than 0.5 L X 3 Bottles. The Package Must Have A Bar Code For Entering Data Into The Analyzer Software. Closed System. Reagent Composition: Organic Quaternary Chlorides And Ammonium 8.5G/L Sodium Chloride 0.6G/L Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer. The Consumer Packaging Must Be Equipped With A Barcode Containing All The Information About The Reagent Necessary For The Operation Of The Analyzer., Alpha-Amylase Eps Ba400 2X60ml+2X15ml Alpha-Amylase Set Of Biochemical Reagents From The Set Biochemical Analyzer - Turbidimetric Ba400 Closed System. The Presence Of A Barcode On Each Vial, Pancreatic Profile, 4-Nfmh, Immunoinhibition, Liquid Bireagent. Composition: Reagent A. Hepes 50 Mmol/L, Calcium Chloride 0.075 Mmol/L, Sodium Chloride 90 Mmol/L, Magnesium Chloride 13 Mmol/L, Α-Glucosidase > 4 U/Ml, Monoclonal Antibodies (Mouse) 50 Mg/L, Ph 7.1. Reagent B. Hepes 50 Mmol/L, 4-Nitrophenyl-Maltoheptaoside-Ethylidene 18 Mmol/L, Ph 7.1. Metrological Characteristics: Threshold Sensitivity: 4.30 Ed/L = 0.072 Μkat/L. Limits Of Linearity: 1300 Ed/L = 21.6 Μkat/L. Accuracy: Serum. The Average Concentration Is 66 Ed/L = 1.10 Μcat/L. Repeatability (Cv) - 1.5%, Intralaboratory Index (Cv) - 1.7%; Average Concentration: 149 Ed/L = 2.47 Μkat/L. Repeatability (Cv) 1.4%, Intralaboratory Index (Cv) - 1.4%. Accuracy: Urine. The Average Concentration Is 62 U/L = 1.03 Μcat/L. Repeatability (Cv) - 2.1%, Intralaboratory Index (Cv) - 2.5%; Average Concentration: 124 Ed/L = 2.06 Μkat/L. Repeatability (Cv) 1.3%, Intralaboratory Index (Cv) - 1.9%. Number Of Studies - 450, Packaging 2X60ml+2X15ml, T+2 +8 C. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer, Glucose From A Set Biochemical-Turbidimetric Analyzer Va400 (10X60ml) Glucose A Set Of Biochemical Reagents From A Set Biochemical-Turbidimetric Analyzer Ba400 Closed System, Barcode On Each Vial. Diabetic Profile; Glucooxidase, End Point; Liquid Monoreagent. Composition: Reagent A. Phosphate 100 Mmol/L, Phenol 5 Mmol/L, Glucose Oxidase > 10 Units/Ml, Peroxidase > 1 Unit/Ml, 4-Aminoantipyrine 0.4 Mmol/L, Ph 7.5. Metrological Characteristics: Limit Of Detection: 2.8 Mg/Dl = 0.155 Mmol/L. Limit Of Linearity: 500 Mg/Dl = 27.5 Mmol/L. Accuracy: Average Concentration: 88 Mg/Dl = 4.90 Mmol/L. Repeatability (Cv): 1.0%. Intralaboratory Indicator (Cv): 1.7%. Average Concentration: 220 Mg/Dl = 12.2 Mmol/L. Repeatability (Cv): 0.4%. Intralaboratory Index (Cv): 1.1%. The Number Of Studies Is 1,800. Packaging 10X 60 Ml, T+2 +8 C. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer., Test Strips Uriscan 11 St 100 Tests Test Strips Uriscan 11 Strip Urine Analyzers. For The Diagnosis Of The Following Parameters: Erythrocytes, Bilirubin, Urobilinogen, Ketone Bodies, Nitrites, Protein, Glucose, Leukocytes, Specific Gravity, Ascorbic Acid, Ph., Gloves Diagnostic Latex Textured Non-Powdered Non-Sterile Size: 7-8 (M), C-Reactive Protein Ba400 1X60+1X15 Ml C-Reactive Protein Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Analyzer Ba400, Produced By The Company Biosystems S.A (Spain), Closed System, Presence Of A Barcode On Each Bottle. Inflammatory Profile; Latex Agglutination/Antibodies To Crp, Fixed Time; Liquid Bireagent. Composition: Reagent A. Glycine Buffer 0.1 Mol/L, Sodium Azide 0.95 G/L, Ph 8.6. Reagent B. Suspension Of Latex Particles Covered With Antibodies To Human Crp, Sodium Azide 0.95 G/L. Metrological Characteristics: Threshold Sensitivity: 1.9 Mg/L. Limits Of Linearity: 150 Mg/L. Accuracy: Average Concentration 14 Mg/L. Repeatability (Cv) - 2.9%, Intralaboratory Index (Cv) - 4.9%; The Average Concentration Is 43 Mg/L. Repeatability (Cv) -1.5 %. The Total Error (Cv) Is 2.6%. Number Of Studies - 225. Packaging 1X60ml+1X15ml, Storage Temperature +2 +8 ⁰С. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. Reagents Must Be Recommended For Use By The Manufacturer Of Ba200/Ba400 Analyzers., Gram Staining Kit, Cellclean (Cellclean Cleaning Solution) From The Set Automatic Hematological Analyzer Of The Xn-L Series, Models Xn-350, Xn-450, Xn-550 (50 Ml) Cellclean Solution From The Set For The Sysmex Xp300 Analyzer, No More Than 50 Ml/Pack. Closed System. The Packaging Must Have A Bar Code For Entering Data Into The Analyzers Software. Sodium Hypochlorite (5.0% Available Chlorine Concentration) Will Provide Authorization From The Equipment Manufacturer. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer. The Consumer Packaging Must Be Equipped With A Barcode Containing All The Information About The Reagent Necessary For The Operation Of The Analyzer., Hemostatic Elastic Semi-Automatic Tourniquet, Size 45*2.5 Cm, Paper Чл 57 Mm, Thermal Paper Roll Paper For A Thermal Printer, Finger Pulse Oximeter Is A Portable Medical Device For Fast And Accurate Measurement Of Heart Rate And Peripheral Saturation Of Hemoglobin In Arterial Blood With Oxygen In A Non-Invasive Way. Certificate Available. Verification Registration Certificate In The Republic Of Kazakhstan., Alaninaminotransferase From The Set Biochemical-Turbidimetric Analyzer Va400 (8X60ml+8X15ml) Alaninaminotransferase Set Of Biochemical Reagents From The Kit Biochemical-Turbidimetric Analyzer Va400 Closed System Presence Of A Barcode On Each Vial, Liver Profile; 2-Oxyglutarate/L-Alanine, Kinetics; Liquid Bireagent. Composition: Reagent A. Tris 150 Mmol/L, L-Alanine 750 Mmol/L, Lactate Dehydrogenase >1350 Units/L, Ph 7.3. Reagent B. Nadh 1.9 Mmol/L, 2-Oxyglutarate 75 Mmol/L, Sodium Hydroxide 148 Mmol/L, Sodium Azide 9.5 G/L. Metrological Characteristics: Threshold Sensitivity: 8.5 Ed/L = 0.14 Μkat/L. Limits Of Linearity: 500 Units/L = 8.33 Μkat/L. Accuracy: Average Concentration 40.2 Units/L = 0.67 Μkat/L: Repeatability (Cv) - 3.9%, Intralaboratory Index (Cv) - 5.0%; Average Concentration: 133 Units/L = 2.21 Μkat/L. Repeatability (Cv) -1.2%, Intralaboratory Index (Cv) - 1.4%. Number Of Studies - 1800. 8X60ml+X15ml, Storage Temperature +2 +8 ⁰С. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. Reagents Must Be Recommended For Use By The Manufacturer Of Ba200/Ba400 Analyzers, Cholesterin From The Set Biochemical-Turbidimetric Analyzer Va400 (10X60ml) Cholesterin Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Analyzer Va400 Closed System, Barcode On Each Bottle. Lipid Profile; Cholesterol Oxidase/Peroxidase, Endpoint; Liquid Monoreagent. Composition: Reagent A. Pipes 35 Mmol/L, Sodium Cholate 0.5 Mmol/L, Phenol 28 Mmol/L, Cholesterol Esterase > 0.2 U/Ml, Cholesterol Oxidase > 0.1 U/Ml, Peroxidase > 0.8 U/Ml, 4-Aminoantipyrine 0.5 Mmol/L, Ph 7.0 . Metrological Characteristics: Threshold Sensitivity: 4.2 Mg/Dl = 0.109 Mmol/L. Limits Of Linearity: 1000 Mg/Dl = 26 Mmol/L. Accuracy: Average Concentration: 153 Mg/Dl = 3.97 Mmol/L. Repeatability (Cv): 0.7 %. Intralaboratory Indicator (Cv): 1.4%. Average Concentration: 220 Mg/Dl = 5.7 Mmol/L. Repeatability (Cv): 0.6 %. Intralaboratory Index (Cv): 1.0 %. Number Of Studies - 1800. Packaging 10X60ml, Storage Temperature +2 +8⁰С. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer, Urea From The Set Biochemical-Turbidimetric Analyzer Va400 (8X60+8X15ml) Urea Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Analyzer Va400 Closed System. Barcode On Each Bottle. Renal Profile; Urease/Glutamate Dehydrogenase, Fixed Time; Liquid Bireagent. Composition: Reagent A. Tris 100 Mmol/L, 2-Oxoglutarate 5.6 Mmol/L, Urease > 140 Units/Ml, Glutamate Dehydrogenase > 140 Units/Ml, Ethylene Glycol 220 G/L, Sodium Azide 0.95 G/L, Ph 8.0. Reagent B. Nadh 1.5 Mmol/L, Sodium Azide 9.5 G/L. Metrological Characteristics: Threshold Sensitivity: : 3.69 Mg/Dl = 1.72 Mg/Dl Bun = 0.614 Mmol/L. Limits Of Linearity: 300 Mg/Dl = 140 Mg/Dl Bun = 50 Mmol/L. Accuracy: Serum Average Concentration: 26.8 Mg/Dl = 4.47 Mmol/L. Repeatability (Cv): 3.5 %. Intralaboratory Index (Cv): 5.0 %. Average Concentration: 137 Mg/Dl = 22.9 Mmol/L. Repeatability (Cv): 1.1 % Intralaboratory Index (Cv): 1.7 %. Urine Average Concentration: 1291 Mg/Dl = 215 Mmol/L. Repeatability (Cv): 3.1% Intralaboratory Rate (Cv): 4.3%. Average Concentration: 1771 Mg/Dl = 295 Mmol/L. Repeatability (Cv): 2.9% Intralaboratory Rate (Cv): 3.1%. The Number Of Studies Is 1,800. Packaging 8X60+8X15ml, T+2 +8 C. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. Reagents Must Be Recommended For Use By The Manufacturer Of Ba200/Ba400 Analyzers, Asparatminotransferase From The Kit Biochemical-Turbidimetric Analyzer Va400 (8X60ml+8X15ml) Aspartatminotransferase Set Of Biochemical Reagents From The Kit Biochemical-Turbidimetric Analyzer Ba400, Closed System. The Presence Of A Barcode On Each Bottle. Liver Profile; 2-Oxyglutarate/L-Aspartate, Kinetics; Liquid Bireagent. Composition: Reagent A. Tris 121 Mmol/L, L-Aspartate 362 Mmol/L, Malate Dehydrogenase>460 Units/L, Lactate Dehydrogenase > 660 Units/L Ph 7.8. Reagent B. Nadh 1.9 Mmol/L, 2-Oxyglutarate 75 Mmol/L, Sodium Hydroxide 148 Mmol/L, Sodium Azide 9.5 G/L Metrological Characteristics: Threshold Sensitivity: 7.15 Ud/L = 0.119 Μkat/L. Linearity Limits: : 500 Ud/L = 8.33 Μkat/L. Accuracy: Average Concentration 41.5 Units/L = 0.69 Μkat/L. Repeatability (Cv) - 2.6%, Intralaboratory Index (Cv) - 5.8%; Average Concentration: 154 Ed/L = 2.55 Μkat/L. Repeatability (Cv) 1.0%, Intralaboratory Index (Cv) - 2.7%. The Number Of Studies - 1800, Packaging 8X60ml+8X15ml, T+2 +8 C. Will Provide Authorization From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer. Ba200/Ba400., C-Reactive Protein Standard From A Set Biochemical-Turbidimetric Analyzer Ba400 (1X1ml/5Ml) C-Reactive Protein Standard A Set Of Biochemical Reagents From A Set Biochemical-Turbidimetric Analyzer Ba400, Produced By Biosystems S.A (Spain), Packaging 1Ml, Bilirubin (General) From The Set Biochemical-Turbidimetric Analyzer Va400 (8X60+8X15ml), I-Chroma Tn I (Troponin I) Troponin I 25 Test Strips For A Portable Analyzer. Test Strips For A Portable Analyzer, 32 Mm Intrauterine Spiral, Bilirubin (Direct) From The Set Biochemical-Turbidimetric Va400 Analyzer (4X60ml+4X15ml) Bilirubin (Direct) Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Va400 Analyzer, Closed System. The Presence Of A Barcode On Each Bottle. Liver Profile; Diazosulfonyl Acid/Sodium Nitrite, Endpoint; Liquid Bireagent. Composition: Reagent A. Phosphoric Acid 90 Mmol/L, Dihydroxyethylethylenediamineacetic Acid Acid (Hedta) 4.5 Mmol/L, Sodium Chloride 50 Mmol/L, Ph 1.5. Reagent B. 3.5-Dichlorophenyl-Diazonium 1.5 Mmol/L. Metrological Characteristics: Threshold Sensitivity: 0.09 Mg/Dl = 1.60 Μmol/L. Limits Of Linearity: 15 Mg/Dl = 257 Μmol/L. Accuracy: Average Concentration 0.608 Mg/Dl = 10.4 Μmol/L Repeatability (Cv) - 4.3%, Intralaboratory Index (Cv) - 5.3%; Average Concentration: 1.68 Mg/Dl = 28.8 Μmol/L. Repeatability (Cv) 2.0%, Intralaboratory Index (Cv) - 2.9%. Number Of Studies -900, Packaging 4 X 60 Ml + 4 X 15 Ml, T+2 +8 C. Will Provide Authorization From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer.
Key Value
Tender Value
3,813,639 - KZT
Tender Documents
Global Tender Document
96b0f01c-30b8-4d7b-9f3e-1648fba41680.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.