GTR 89155395
Bids Are Invited For Contracting For Rental Of Cpap Devices (Ventilator For Non-Invasive Ventilation Support) And Bilevel Equipment (Device With Two Pressure Levels - Ipap And Epap) With Provision Of Installation, Assembly And Preventive And Corrective Technical Maintenance Services.
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
89155395
Tendering Authority
Subscribe to view
Tender No
057/2024
Financer Name
Self-Funded
Work Title
Bids Are Invited For Contracting For Rental Of Cpap Devices (Ventilator For Non-Invasive Ventilation Support) And Bilevel Equipment (Device With Two Pressure Levels - Ipap And Epap) With Provision Of Installation, Assembly And Preventive And Corrective Technical Maintenance Services.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
10-12-2024
Closed
Work Detail
Rental Of Cpap (Basic) Medical Devices (Ventilator For Non-Invasive Ventilatory Support), With Heated Humidifier And Memory Card Or Similar Technology For Data Transfer Pressure Range: Minimum 4 To 20 Cmh2o. Ramp Time Up To 45 Minutes, With Minimum Increment Of Every 5 Min. Voltage: Automatic Bivolt Circuit: Maximum 2 Meters Noise Level: Less Than Or Equal To 35Db. Must Contain: Attached Or Integrated Humidifier, Automatic Altitude Adjustment, Filter, Relief System During Expiration, Silicone Or Facial Interface. The Company Must Be Responsible For Maintenance Of The Device, As Well As Immediate Exchange If There Is Any Defect. The Circuit And Interface Must Be Included And Replaced Every Six Months Or Whenever Necessary (Malfunction). After Evaluation By Sads Technical Team, Rental Of Medical Devices Bilevel Equipment (Device With Two Pressure Levels, Ipap And Epap) Ipap: Minimum Of 4 To 30 Cmh2o, Epap: Minimum Of 4 To 25 Cmh2o Modes: Controlled, Assisted Controlled, Spontaneous Ventilation Support With Guaranteed Volume. Mandatory Frequency - 5 To 60 Irpm, Monitoring: Pressure, Tidal Volume, Minute Ventilation, Respiratory Rate, Leak. Alarms: Disconnection, Apnea, Voltage: Automatic Bivolt, Circuit: Maximum 2 Meters, Low Noise Level. Must Contain: Automatic Adaptation Of Battery Leakage For Internal Or Ups Operation With Autonomy Of Approximately 04 Hours In The Absence Of Electricity, Attached Or Integrated Humidifier, Nasal Or Facial Silicone Interface, Registration With Anvisa. The Company Must Be Responsible For Maintaining The Device, As Well As Replacing It Within 24 Hours If There Is A Defect. The Circuit And Interface Must Be Included And Replaced Every Six Months Or Whenever Necessary (Malfunction). After Assessment By The Sad Technical Team, 11/26/2024
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
bf662f6b-677a-4fbb-947f-6a6cd66aecb0.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.