GTR 87759934

Request For Quotation Purchase Of Medical Products (Cardiac Surgery)

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
87759934
Tendering Authority
Subscribe to view
Tender No
13271834
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Medical Products (Cardiac Surgery)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
01-11-2024 Closed
Work Detail
Single-Stage Venous Cannula, Angular 90 Degrees/With Variable Bending Angle, Sizes (Fr) 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38, 40, Cannulas Have A Protective Shaped, One-Piece, Bend-Resistant, Reinforced Body With A Conical Tip With Multiple Side Holes, Which Facilitates The Introduction Of The Cannula. The Design Of The Cannula Allows The Surgeon To Give The Cannula The Desired Shape And Position. It Provides Higher Flow Rates With A Minimal Pressure Difference. Insertion Depth Markers Ensure The Optimal Position Of The Cannula, Set For Percutaneous Introduction Of Cannulas, Set For Preparation For Arterial Or Venous Peripheral Vascular Cannulation. The Set Includes:• 4 Vasodilators: 10/12 Shr., 12/14 Shr., 14/16 Shr., 16/18 Shr.• Arterial Cannula Guide 0.038 (0.097 Cm) X 100 Cm, J-Tip • Venous Cannula Guide 0.038 (0.097 Cm) X 150 Cm, J-Tip • Guide Advance Device • 18 Ga Puncture Needle (1, 27 Mm) • Mini-Scalpel • Syringe 10 Ml, Temporary Myocardial Electrodes (Adults) For Stimulation Consist Of A Contact (1) And An Insulated Multiwire Conductor (2), Connected To Each Other. A Blue Monofilament (3), Coiled At The Proximal End Into A Spiral For Fixing The Electrode And Ending Distally With A Curved Atraumatic Myocardial Needle (4) Is Attached To The Contact. The Spiral Of The Blue Monofilament Secures The Electrode During Implantation In The Myocardial Tissue. Atraumatic Thoracic Needle (5) At The Proximal End Of The Wire Conductor Ensures The Introduction Of The Electrode For Stimulation Through The Chest Wall. To Remove The Electrode For Stimulation, It Is Necessary To Carefully Pull It. Do Not Leave Any Parts Of The Electrode In The Body. One (1) Temporary Stimulation Electrode Is Supplied In A Sterile Package With One (1) Pin Connector Cap., Aortic Arch Cannula With A 5-9Fr Drainage Line. Cannulas Have A Radiopaque Tip Connected To A Transparent Body. Additional Functions Available When Using This Cannula Include: Monitoring Of Pressure In The Root Of The Aorta, Drainage Of The Left Heart. All Cannulas Are Equipped With A Steel Needle-Introducer., Peripheral Venous Cannulas For Extracorporeal Membrane Oxygenation, Sizes: 19Fr, 21Fr, 23Fr, 25Fr, 29Fr. Length: 38 Cm, 55 Cm. Side Holes At A Length Of 38 Cm: 19Fr – 12 Pcs., 21Fr – 12 Pcs., 23Fr – 16 Pcs., 25Fr – 20 Pcs. Side Holes At A Length Of 55 Cm: 21Fr – 20 Pcs., 23Fr – 20 Pcs., 25Fr – 24 Pcs., 29Fr – 32 Pcs. Perforation Length At A Length Of 38 Cm: 10 Cm. Perforation Length At A Length Of 55 Cm: 20 Cm. Connector: 3 /8., Y-Shaped Recirculation Adapter, The Adapter Has A Length Of 12.7 Cm, A Male Luer Port On One End And A 1/4 (0.64 Cm) Drain Connector On The Other, Intracoronary Shunts 1.0 Mm-3.0 Mm To Preserve Coronary Blood Flow During Anastomosis. Thickened Tips, Soft Silicone Construction, Middle Fold Line, Radiopaque, Transparency. Size 1.0 Mm-3.0 Mm, Cannula For Mouth Perfusion With A 45° Tip / With A 90° Tip Size: 12 Fr., Cannula For Mouth Perfusion Is Used When Injecting A Cardioplegic Solution Directly Into The Coronary Artery During The Operation In The Conditions Of Artificial Blood Circulation. Basket Tip, Various Configurations, Soft Stainless Steel Pin. The Cannulas End With The Covering Part Of The Screw Luer Connection Of The Luer-Mother Type. With An Angle Of Inclination Of 45/90 Degrees, Dimensions Of 12.0 Fr., Model Patient Cable (Atrial), Designed To Connect Atrial Electrode Systems For Stimulation To A Temporary Ecs For Temporary External Cardiac Stimulation. Patient Cables Have Recessed Protected Contacts. They Are Suitable For Multiple Use, Non-Sterile And Must Be Steam Sterilized (Withstand Up To 25 Cycles Of Autoclaving) Or Ethylene Oxide Before Use. The Electrode Connector At One End Of Each Cable Is Intended For Connecting An Endocardial Or Myocardial Plug Of An Electrode For Stimulation With A Diameter From 0.38 To 2.41 Mm. The Connector With A Clamp At The Other End Of Each Cable Is Intended For Connection With The Terminal Of The Ex Output, Arterial Cannula Thin-Walled 18-24 Fr, Arterial Cannulas With A Thin-Walled Tip, An Elongated One-Piece Body Resistant To Bends And Reinforced Walls. Equipped With Markings For The Depth Of Insertion. Length 30.5 Cm, Red Hemostatic Cap. It Is Completed With An X-Ray Ring For Adjusting The Depth Of Insertion And An Introducer With A Dilating Tip. Connector 3/8 (0.95 Cm) Can Be With Or Without A Luer Port No. 10 In A Package. Sizes: 18 Fr (6.0 Mm), 20 Fr (6.7 Mm), 22 Fr (7.3 Mm), 24 Fr (8.0 Mm)., Femoral Cannulas In A Set And Without, Size (Fr): 8, 10, 12, 14, 15, 17, 19, 21, 23, 25, 27, 28, 29, Sterile, Single Use, The Cannula Consists Of An Elongated Solid, Stable To The Bends Of The Wire-Wound Pvc Body With Side Ports At The Distal End, The Multi-Port Basket, And The Connector. The Total Maximum Length Of The Cannula Is Approximately 76.2 Cm. The Presence Of The Introducer, Expander, Conductor And Markings Of The Depth Of Introduction Allow You To Optimally Position The Cannula. The Dilator Is Equipped With A Conical Tip And A Limiting Ring Designed To Cover The Distal End Of The Cannula During Insertion. The Indicator Strip On The Dilator Tip Shows When The Dilator Is Fully Retracted Into The Cannula Body. A Wire Guide Can Be Passed Through The Expander, Facilitating The Introduction. The System Is Sterile, Non-Pyrogenic And Intended For Single Use., Applicator For Ligating Titanium Clips, Single-Use Hemoconcentrator, High Flux Hollow Fiber Material Membrane Area (M2) 1.2 Fiber Inner Diameter (Μm) 200 Fiber Outer Diameter (Μm) 260 Fiber Wall Thickness (Μm) 30 Fiber Length (Mm) 225 Number Of Fibers 9300 Body Inner Diameter Filter (Mm) 38 Primary Blood Volume (Ml) 75 Maximum Transmembrane Pressure (Mm Hg) 600 Cartridge Body Material - Polycarbonate (Pc) / Copolyester - Bpa Free Cartridge Blood Port Material - Polycarbonate (Pc) / Copolyester - Bpa Free Connectors For Blood Cartridges Twist Lock Cartridge Filtrate/Dialysate Connectors Female Luer Lock Block Length (Mm) 265 Ultrafiltration Speed (Ml/H/Mm Hg) 55 ., The External Temporary Two-Chamber Pacemaker Is Intended For Temporary Stimulation Of The Atrium And/Or Ventricle For Therapeutic, Preventive, And Diagnostic Purposes. The Temporary Pacemaker Provides 7 Selectable Modes Of Stimulation Therapy: Ddd, Ddi, Doo, Aai, Aoo, Vvi, And Voo. High-Frequency Pulse Stimulation Therapy Up To 800 Min-1 For Atrial Tachyarrhythmias Is Available In Asynchronous Mode. Frequency Of Atrial Pacing - 80-800 Beats/Min. Cardiostimulation Frequency - 30-200 Beats/Min. Upper Frequency -80-230 Beats/Min. Safe Speed - (Frequency < 86 Imp/Min: 110 Ms; Frequency 86 Imp/Min: 70 Ms). Pacemaker Dimensions: Height 20.3 Cm, Width 8.6 Cm, Thickness 4.45 Cm, Weight 680 G. Battery Life - At Least 7 Days. Functioning After Removing The Battery - 30S. Materials - Body: Ge Cycloloy C2950- Pc/Abs; Device: Polyester Plastic, Polycarbonate, Catheter For Drainage Of The Left Ventricle, Size: 16Fr- 20 Fr; (Silicone), Left Ventricular Drains Are Used For Direct And Indirect Drainage Of The Left Ventricle And Have A Perforated Tip. A Wide Selection Of Models With A Silicone Or Pvc Body, With A Straight, Curved Or Flexible Body, With Markings Of The Insertion Depth. Straight Body Models Come With A Flexible Or Rigid Introducer For Ease Of Installation And Insertion. All Left Ventricular Catheters Terminate In A 1/4 Inch (0.64 Cm) Vented Or Non-Vented Connector. Dimensions According To The Customers Request, A Surgical Cable With Alligator Clips Is Connected To Implantable Electrodes For Stimulation Of Heart Chambers. The Cable Has Four Crocodile Clips For Connecting To The Connector Ends Of Implantable Electrodes For Stimulation. Cable Length > 3 M. The Cable Is Intended For Multiple Use, It Is A Disposable Stabilizer Based On A Retractor, Which Consists Of Two Tissue Stabilizers Attached To A Hinged Lever (To The Lever). The Lever Is Attached To The Retractor With The Help Of A Fastening Clip. The Valve Provides On/Off Suction Control. When A Tissue Stabilizer Is Placed On Both Sides Of The Anastomotic Site, Suction Acts To Stabilize The Tissue. The Lever Is Tightened And Loosened With A Handle. Sterile, Non-Pyrogenic, Single-Use Only., A Two-Stage Venous Cannula With A Flexible Line With A Reinforced Proximal And Distal End Without A Connector/With A Connector. The Cannulas Have A Radiopaque Tip Connected To The Transparent Body By A Separate Drainage Line. Additional Functions Available When Using This Cannula Include: Pressure Monitoring At The Root Of The Aorta, Drainage Of The Left Heart. All Cannulas Are Equipped With A Steel Needle-Introducer. Sizes 32/40 Fr, 34/46 Fr, 36/46 Fr; 36/51 Fr.
Key Value
Tender Value
8,293,500 - KZT
Tender Documents
Global Tender Document
c5f0eb15-a196-4233-ba66-6f0b77e9d893.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you