GTR 87368320
Request For Quotation Purchase Of Medical Products
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
87368320
Tendering Authority
Subscribe to view
Tender No
13233918
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Medical Products
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
22-10-2024
Closed
Work Detail
Urea From The Set Biochemical-Turbidimetric Analyzer Va400 (8X60+8X15ml) Urea Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Analyzer Va400 Closed System. Barcode On Each Bottle. Renal Profile; Urease/Glutamate Dehydrogenase, Fixed Time; Liquid Bireagent. Composition: Reagent A. Tris 100 Mmol/L, 2-Oxoglutarate 5.6 Mmol/L, Urease > 140 Units/Ml, Glutamate Dehydrogenase > 140 Units/Ml, Ethylene Glycol 220 G/L, Sodium Azide 0.95 G/L, Ph 8.0. Reagent B. Nadh 1.5 Mmol/L, Sodium Azide 9.5 G/L. Metrological Characteristics: Threshold Sensitivity: : 3.69 Mg/Dl = 1.72 Mg/Dl Bun = 0.614 Mmol/L. Limits Of Linearity: 300 Mg/Dl = 140 Mg/Dl Bun = 50 Mmol/L. Accuracy: Serum Average Concentration: 26.8 Mg/Dl = 4.47 Mmol/L. Repeatability (Cv): 3.5 %. Intralaboratory Indicator (Cv): 5.0 %. Average Concentration: 137 Mg/Dl = 22.9 Mmol/L. Repeatability (Cv): 1.1 % Intralaboratory Index (Cv): 1.7 %. Urine Average Concentration: 1291 Mg/Dl = 215 Mmol/L. Repeatability (Cv): 3.1% Intralaboratory Rate (Cv): 4.3%. Average Concentration: 1771 Mg/Dl = 295 Mmol/L. Repeatability (Cv): 2.9% Intralaboratory Rate (Cv): 3.1%. The Number Of Studies Is 1,800. Packaging 8X60+8X15ml, T+2 +8 C. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. Reagents Must Be Recommended For Use By The Manufacturer Of Ba200/Ba400 Analyzers, Uric Acid From A Set Biochemical - Turbidimetric Analyzer Ba400 (10X60ml) Uric Acid Set Of Biochemical Reagents From A Set Biochemical - Turbidimetric Analyzer Ba400, Produced By The Company Biosystems S.A (Spain), Closed System, Barcode On Each Bottle. Renal Profile; Uricase/Peroxidase, Endpoint; Liquid Monoreagent. Composition: Reagent A. Phosphate 100 Mmol/L, Detergent 1.5 G/L, Dichlorophenol Sulfonate 4 Mmol/L, Uricase > 0.12 U/Ml, Ascorbate Oxidase > 5 U/Ml, Peroxidase > 1 U/Ml, 4-Aminoantipyrine 0.5 Mmol/L, Ph 7.8. Metrological Characteristics: Threshold Sensitivity: : 0.31 Mg/Dl = 18.5 Μmol/L. Limits Of Linearity: 25 Mg/Dl = 1487 Μmol/L. Accuracy: Serum Average Concentration: 5.2 Mg/Dl = 311 Μmol/L. Repeatability (Cv): 1.3 %. Intralaboratory Indicator (Cv): 1.9 %. Average Concentration: 10.8 Mg/Dl = 643 Μmol/L. Repeatability (Cv): 0.7% Intralaboratory Index (Cv): 1.1%. Urine Average Concentration: 20.9 Mg/Dl = 1243 Μmol/L. Repeatability (Cv): 2.5 %. Intralaboratory Indicator (Cv): 3.4%. Average Concentration: 41.8 Mg/Dl = 2486 Μmol/L. Repeatability (Cv): 1.9% Intralaboratory Rate (Cv): 2.8%. The Number Of Studies Is 1,800. Packaging 10X60 Ml, T+2 +8 C. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. Reagents Must Be Recommended For Use By The Manufacturer Of Ba200/Ba400 Analyzers, Alaninaminotransferase From The Set Biochemical-Turbidimetric Analyzer Va400 (8X60ml+8X15ml) Alaninaminotransferase Set Of Biochemical Reagents From The Kit Biochemical-Turbidimetric Analyzer Va400 Closed System Presence Of A Barcode On Each Vial, Liver Profile; 2-Oxyglutarate/L-Alanine, Kinetics; Liquid Bireagent. Composition: Reagent A. Tris 150 Mmol/L, L-Alanine 750 Mmol/L, Lactate Dehydrogenase >1350 Units/L, Ph 7.3. Reagent B. Nadh 1.9 Mmol/L, 2-Oxyglutarate 75 Mmol/L, Sodium Hydroxide 148 Mmol/L, Sodium Azide 9.5 G/L. Metrological Characteristics: Threshold Sensitivity: 8.5 Ed/L = 0.14 Μkat/L. Limits Of Linearity: 500 Units/L = 8.33 Μkat/L. Accuracy: Average Concentration 40.2 Units/L = 0.67 Μkat/L: Repeatability (Cv) - 3.9%, Intralaboratory Index (Cv) - 5.0%; Average Concentration: 133 Units/L = 2.21 Μkat/L. Repeatability (Cv) -1.2%, Intralaboratory Index (Cv) - 1.4%. Number Of Studies - 1800. 8X60ml+X15ml, Storage Temperature +2 +8 ⁰С. Provide A Power Of Attorney From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. Reagents Must Be Recommended For Use By The Manufacturer Of Ba200/Ba400 Analyzers, Asparatminotransferase From The Kit Biochemical-Turbidimetric Analyzer Ba400 (8X60ml+8X15ml) Asparatminotransferase Set Of Biochemical Reagents From The Kit Biochemical-Turbidimetric Analyzer Ba400, Closed System. The Presence Of A Barcode On Each Bottle. Liver Profile; 2-Oxyglutarate/L-Aspartate, Kinetics; Liquid Bireagent. Composition: Reagent A. Tris 121 Mmol/L, L-Aspartate 362 Mmol/L, Malate Dehydrogenase>460 Units/L, Lactate Dehydrogenase > 660 Units/L Ph 7.8. Reagent B. Nadh 1.9 Mmol/L, 2-Oxyglutarate 75 Mmol/L, Sodium Hydroxide 148 Mmol/L, Sodium Azide 9.5 G/L Metrological Characteristics: Threshold Sensitivity: 7.15 Ud/L = 0.119 Μkat/L. Linearity Limits: : 500 Ud/L = 8.33 Μkat/L. Accuracy: Average Concentration 41.5 Units/L = 0.69 Μcat/L. Repeatability (Cv) - 2.6%, Intralaboratory Index (Cv) - 5.8%; Average Concentration: 154 Ed/L = 2.55 Μkat/L. Repeatability (Cv) 1.0%, Intralaboratory Index (Cv) - 2.7%. Number Of Studies - 1800, Packaging 8X60ml+8X15ml, T+2 +8 C. Will Provide Authorization From The Manufacturer Of The Equipment. The Reagents Must Meet The Requirements Specified In The Manual For The Equipment. The Possibility Of Using Reagents Should Not Contradict The Official Recommendations Of The Equipment Manufacturer. Ba200/Ba400., A Centrifuge Tube With A Lid Of 15 Ml
Key Value
Tender Value
429,900 - KZT
Tender Documents
Global Tender Document
5e9764e0-6c09-4d0f-8fc2-c6dad3236549.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.