GTR 87328593

Request For Quotation Acquisition Of A Training Ground For Electricians

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
87328593
Tendering Authority
Subscribe to view
Tender No
13213471
Financer Name
Self-Funded
Work Title
Request For Quotation Acquisition Of A Training Ground For Electricians
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
23-10-2024 Closed
Work Detail
Low-Voltage Porcelain Tf-20 Pin Insulators Are Intended For Insulation And Fastening Of Wires On Overhead Power Lines, In Switchgear (Ru) Of Power Plants And Substations Of Alternating Current With A Voltage Of Up To 1000 V, Cable Communication And Radio Broadcasting Networks. The Tf-20 Insulator Is Installed On A Standard Kn-18 Hook Or Low-Voltage Traverses With Uninsulated Wires Through Kp-18 Caps. Nominal Voltage: Up To 1 Kv. Minimum Breaking Force: 8.0 Kn. The Diameter Of The Insulator Mounting Pin: 18 Mm. Weight: 0.49 Kg., Disconnector. Nominal Voltage, Kv: 10. Maximum Working Voltage, Kv: 12. Nominal Current, A: 400, 630. Current Of Thermal Resistance, Ka: — For Grounding Knives For 1 S: 10; — For Eye Knives Within 3 S:10. The Largest Peak Of The Nominal Short-Term Withstand Current (Current Of Electrodynamic Resistance), Ka: 25. The Length Of The Leakage Path Of The External Insulation, Not Less, Cm: 30. The Permissible Mechanical Load On The Outputs, Taking Into Account The Influence Of Wind And Ice, Not Less, N: 200. Electrical Resistance Of The Main Circuit, Ohm: 175×106. The Greatest Effort Applied To The Drive When The Length Of The Operating Handle Together With The Extension Is No More Than 1.0 M, H: 245. Mass No More, Kg: 38. Overall Dimensions, Mm: 1200×470×385. The Disconnector And Drive Are Manufactured In Uhl Category 1 According To Gost., Glass Linear Pin Insulator Shs-10Ed, Intended For Insulation And Fastening Of Wires On Vlep And In Distribution Devices Of Power Plants And Alternating Current Substations For A Voltage Class Of Up To 10 Kv With A Frequency Of Up To 100 Hz, In The Temperature Range From - 60С To 50С. Type Of Insulator Shtyrevoy. Constructive Performance Linear. Resistance To Aggressive Environments Yes. Nominal Voltage, Kv: 10. The Length Of The Leakage Path, Mm: 340. Min. Mechanical Destructive Load, Kn: 12.5. Max. Withstand Voltage 50Hz (In Dry State), Kv: 68. Max. Withstand Voltage 50 Hz (Under Rain), Kv: 42. Max. Withstanding Impulse Voltage 1.2/50+/-, Kv: 130/130. Weight, Kg: 2.2., Universal Ladders No. 2 Are Intended For Moving Along Reinforced Concrete Supports Of Trapezoidal Cross-Section Of Overhead Power Lines Type Sv 110-1A; Sv95-1A (2A); Sv105-3,6; Sv105-5. The Adjustment Of The Climbing Solution Is Carried Out With The Help Of A Retractable Bracket, Which Is Fixed With Two Bolts With Nuts And Washers. Complete With Fastening Straps Made Of Genuine Leather. The Solution Of The Ladder (The Distance Between The Spikes In The Projection On The Plane Of The Footboard) Including Adjustment — Min 175+5 Mm, Max-190+5 Mm. Climbing Ladder - Min 122 + 5 Mm, Max - 131 + 5 Mm. The Mass Of Universal Ladders Complete With Fastening Belts Is No More Than 5.5 Kg., Belt With Safety Support Belt. Belt Sizes: Adjustable Webbing Belt: ― Two Attachment Points For Fall Protection (On The Back And Chest). ― Strap Width: 45 Mm. ― Safety Support Belt With Lumbar Thermoformed Support. ― Two Attachment Points For Support (On The Sides). ― Three Adjustable Buckles. Material: Straps And Belt: Polyester, Buckles: Stainless Steel. Belt Lining: Terry Cloth Material. Advantages Of The Product: Lightness And Ease Of Use. Strengths: Ergonomic ― Adapted For The Most Comfortable And Safe Work. There Are Buckles For Adjusting The Length Of The Straps, An Auxiliary Strap With A Fastener On The Chest, Two Attachment Points: On The Back And Chest., Ac-35/6.2 Wire For Overhead Power Lines. Brand: As. Number Of Veins: 1. Section Size, Mm2: 35. Voltage 10 Kv., A Set Of Posters On Electrical Safety. The Set Of 13 Electrical Safety Posters Includes: 1. Do Not Include Working People 100X200 Mm. 2. Do Not Open Working People 100X200mm. 3. Grounded 100X200 Mm. 4. Do Not Include Work On The 100X200 Mm Line. 5. Work Under Voltage. Do Not Include 100X200mm Again. 6. 150X150mm Will Work Here. 7. 150X150mm Fit Here. 8. Stop! Tension 300X150 Mm. 9. The Test Is Dangerous For Life 300X150 Mm. 10. Do Not Enter The 300X150 Mm. 11. Danger Of Electric Shock (Lightning) 150X150x150 Mm. 12. Dangerous! Electric Field! Passage Is Prohibited Without Means Of Protection - 100X200mm. 13. Danger Of Electric Shock (Lightning) 200X200x200 Mm., Dummy Simulator For Rescuers, Firemen, Electricians. The Mannequin Is Made To Imitate The Human Body In An Unconscious State. The Training Mannequin Is Ideal For Training And Training Rescuers During Emergency Rescue Work At High-Rise Civil And Industrial Facilities, Removing Victims From Power Lines, Cranes, Collapsed Roofs, Etc., As Well As For Testing Safety Equipment For Rescuers And Industrial Climbers Technical Characteristics Of The Mannequin: - Adult: Height 175 Cm, Weight 50 Kg. The Mannequin Is Made Of Durable Molded Wear-Resistant Awning Fabric - Reinforced Pvc With A Density Of 650 G/M2 (Polyvinyl Chloride, Does Not Rot, Is Not Afraid Of Moisture And Minus Temperatures), Reinforced With Slings Around The Mannequins Body And Limbs. Reinforced Seams. Filling: Separate Bags With Calibrated Rti Crumb, Which Does Not Rot, Is Not Afraid Of Moisture And Minus Temperatures. The Mannequin Is Equipped With: 1) Rubber Boots With The Possibility Of Fixing Them With Straps To The Legs To Avoid Abrasion Of The Mannequin When Dragging And Involuntary Removal Of The Boots. 2) A Work Suit (Jacket And Pants) To Protect The Mannequin From Contamination And Abrasion During Training. 3) Construction Helmet., Power Transformer Included. Gost 14695-97. Ktpn-100/10-0.4Kv (Bb/Bb), Dead-End Type, With Rlnd-10/ Not Less Than 630A And Rvo- Not Less Than 10 Kv, On The Low-Voltage Input With A Circuit Breaker Not Less Than 250A, On Outgoing Lines With Automatic Switches Not Less Than 1*100A, 1*80A, 1*63A With Street Lighting Feeder Photorelay Fr-2, With Transformer Tmg-100/ Not Less Than 10-0.4Kv. 1. Power, Oil, Three-Phase Transformer. Power Kva-160. Scheme And Group Of Connection Of Windings U/Un-0. 2. The Voltage Is Not Less Than 10 Kv/0.4 Kv. 3. Type Of High-Voltage Input (Hv)-Air; 4. Output On The Side (Nn) - Air, Cable; 5. Type Of Neutral Of The Transformer On The Low Side (Lv) - Deafly Grounded. 6. Accounting Device - Sa4u-E720 3X220/380V 5(7.5)A Dala Conditions For A Potential Supplier: 1. The Potential Supplier Must Guarantee That The Quality Of The Supplied Goods Meets The Requirements Of The Technical Specification. 2. Terms Of Delivery: Delivery Of Transformer Substations Is Made In The Places Specified By The Customer For Further Operation. 3. Mandatory Provision Of The Certificate Of Origin Of The Goods In The Form St-Kz 4. The Supplier Must Deliver The Goods New, Unused, In Factory Packaging, Without Any Defects 5. Provision Of A Product Warranty With A Term Of At Least 12 Months., Traversy Tm High-Voltage 6-10 Sq. Tm Traverses Tm Are Used For Fastening Wires, Cables, Ropes, Insulators, Disconnectors On Power Lines And Substations Up To 10 Kv. The Traverses Are Intended For Carrying Out And Fastening Power Transmission Lines And Are Installed On Poles Of Both Round And Square Sections, Fastening Is Carried Out With The Help Of A Clamp. The Constructions And Device Of The Traverse And Anchored Are Various. Traverse Type: T-Shaped. Central Element: Axial Lug. Traverse Material: Steel., Ac 50/8 Wire. Flexibility: Flexible. Guest: Yes. Number Of Wires: 1. Metraznyy Goods: Yes. Core Material: Aluminum. Material Of Insulation And Shell: No., Sip Cable. Sip-4 Is A Self-Supporting Insulated Wire (Type-4) With Aluminum Cores Covered With Light-Stabilized Cross-Linked Polyethylene Insulation. Self-Supporting Insulated Wire Of The Sip-4 Brand. It Is Used For Overhead Power Lines And Branched To Water In Residential Buildings, Household Buildings In Areas With Moderate Cold And Climate. Construction. Core: Aluminum, Round, Multi-Wire, Sealed. Insulation: From Thermoplastic Light-Stabilized Polyethylene. Twisting: Insulated Conductors Are Twisted Between Themselves. The Twist Has A Right Direction. Features: Flexibility: Flexible. Guest: Yes. Number Of Cores: 4. Core Material: Aluminum. Material Of Insulation And Shell: Polyethylene Insulation. Purpose: Insulated For Overhead Lines. Availability Of Metal Armor: No. Voltage: 1 Kv. Section: 35 Mm2., Portable Grounding. Nominal Voltage Of Grounding, Hv, Kv: 0.4-10. The Total Length Of The Grounding Rod With Clamp, Mm: 1300. The Length Of The Insulating Part Of The Rod, Mm: 700. The Number Of Grounding Rods With Clamps, Pcs. 3. Cross-Section Of The Grounding Wire, Mm: 25. Length Of The Wire Between The Phases, M: 1.6. The Length Of The Grounding Descent, M: 10.2. The Length Of The Rod Handle, Mm: 300. The Thermal Resistance Current For 3 Seconds, Ka: 3.6. Dynamic Withstand Current, Ka: 22. Mass, Kg: 6.5., Anchor Clamp. The Cross-Section Of The Retained Sips, Mm²: 16...35. Number Of Cables: 4. Cable Clamping Diameter, Mm: 7.2...9.7. Model Or Version: Insulated. Length, Mm: 203. Weight, Kg: 0.14. Nominal Voltage, V: 1000. Color: Black. Width, Mm: 42. Height, Mm: 62. Max Stretching Load, H: 2284. Material: Steel/Plastic., High Voltage Indicator. Device Type: Voltage Indicator. Nominal Voltage Of 10 Kv. Nominal Voltage With 6 Kv. Type Of Indication: Optical. With Self-Testing: Yes. Ves, G:464., The Supporting Clamp Sm-130 Is Intended For Intermediate Supporting Fastening Of The Sip-4 Wire On Intermediate And Corner Supports With A Rotation Angle Of Up To 60º. The Body Is Made Of Corrosion-Resistant Aluminum Alloy, The Inner Part Is Made Of Weather-Resistant Plastic. Type Of Fittings For Power Lines: Clamp For Power Lines. Material: Aluminum. Resistance To Aggressive Environments: Yes. Height: 0.078 Mm. User Characteristics: Voltage Class: 0.4. Minimum Breaking Load: 18 Kn. Wire Cross-Section, Mm²: 2-4X (16-120)., P4x-150 Piercing Branch Clamp, Intended For Hermetic Connection And Branching Of Insulated Subscriber Wires. Contact Plates: Tinned Copper. Red Head: Aluminum. Metals: Steel With Galvanic Coating. Body: Plastic, Resistant To Ultraviolet Rays And Negative Temperatures. Main Cable Cross-Section, Mm²: 25-150. Cross-Section Of Branch Cable, Mm²: 25-150. Weight, Kg: 0.120.
Key Value
Tender Value
1,238,529 - KZT
Tender Documents
Global Tender Document
a3214719-cbf2-4b7d-8654-c7ea5cf0b091.html
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders