GTR 86812339
Tenders Are Invited For Osteosynthesis Implants (Straight 1/3-Tubular Plate, Combined Holes, With Angular Stability, Titanium; Straight Small Plate, Combined Holes, With Angular Stability, Titanium; Tibial Proximal Lateral 5.0Mm Plate, Right, Combined Holes, With Angular Stability, Tibia Proximal Plate 5.0Mm, With Angled Stability Femoral Plate, Right, With Angled Stability Femoral Plate, Left, With Angled Stability , Titanium; Elbow Ii Plate, Combined Holes, Titanium; Straight Narrow Plate, Combined Holes, Titanium)
ICB — International Competitive Bid
Closed
Eastern Europe
Tender Information
GTR Reference
86812339
Tendering Authority
Subscribe to view
Tender No
UA-2024-10-04-011655-a
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Osteosynthesis Implants (Straight 1/3-Tubular Plate, Combined Holes, With Angular Stability, Titanium; Straight Small Plate, Combined Holes, With Angular Stability, Titanium; Tibial Proximal Lateral 5.0Mm Plate, Right, Combined Holes, With Angular Stability, Tibia Proximal Plate 5.0Mm, With Angled Stability Femoral Plate, Right, With Angled Stability Femoral Plate, Left, With Angled Stability , Titanium; Elbow Ii Plate, Combined Holes, Titanium; Straight Narrow Plate, Combined Holes, Titanium)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Eastern Europe
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
09-10-2024
Closed
Work Detail
1/3 Tubular Plate (Universal Design, Min. Holes ≤ 4, Max. Holes ≥ 10) And Set Of Screws: 5 Locking (L Min. ≤ 15Mm, L Max. ≥ 60Mm) And 2 Cortical (L Min. ≤ 15Mm , L Max. ≥ 60 Mm), Straight Lcp-Plate For Forearm (Version Universal, Min. Holes ≤ 6, Max. Holes ≥ 10) And Set Of Locking Screws: 5 (L Min. ≤15Mm, L Max. ≥70Mm) And 2 Cortical (L Min. ≤ 15Mm, L Max. ≥ 50Mm), Tibial Proximal-Lateral Plate (Right-Hand Design, Min. Holes ≤ 5, Max. Holes ≥ 10) And Set Of Screws: 8 Locking (L Min. ≤ 15Mm , L Max. ≥ 50 Mm) And 4 Cortical (L Min. ≤ 15 Mm, L Max. ≥ 50 Mm), Proximal-Lateral Tibial Plate (Left Version, Min. Holes ≤ 5, Max. Holes ≥ 10) And Set Of Screws : 8 Blocking (L Min. ≤ 15Mm, L Max. ≥ 50 Mm) And 4 Cortical (L Min. ≤ 15Mm, L Max. ≥ 50 Mm), Plate For The Distal Department Of The Femur (Right Handed, Min. Holes ≤ 5) , Max. Holes ≥ 10) And Set Of Screws: 8 Locking (L Min. ≤ 20 Mm, L Max. ≥ 80Mm) And 4 Cortical (L Min. ≤20Mm, L Max. ≥ 80Mm), Distal Femur Plate (Left Design, Min. Holes ≤ 5, Max. Holes ≥ 10) And Set Of Screws: 8 Locking (L Min. ≤ 20Mm, L Max. ≥ 80Mm) And 4 Cortical (L Min. ≤20Mm, L Max. ≥ 80Mm), Lcp-Plate (Universal Version, Min. Holes ≤ 3, Max. Holes ≥ 3) Screws: 8 Blocking (L Min. ≤ 10Mm, L Max. ≥ 100Mm) And 4 Cortical (L Min. ≤ 10Mm, L Max. ≥ 100Mm), Tibial Straight Plate (Universal Design, Min. Holes ≤ 6, Max. Holes ≥ 12) And Set Of Screws: 5 Locking (L Min. ≤ 15Mm, L Max. ≥ 60Mm) And 2 Cortical (L Min. ≤ 15Mm, L Max. ≥ 60Mm)
Key Value
Tender Value
177,900 - UAH
Tender Documents
Global Tender Document
fa1a3bec-c6da-4f50-b82a-38ae373dea49.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.