GTR 84073043

Request For Quotation A Set Of Reagents For The Cs-T240 Biochemical Analyzer

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
84073043
Tendering Authority
Subscribe to view
Tender No
12841986
Financer Name
Self-Funded
Work Title
Request For Quotation A Set Of Reagents For The Cs-T240 Biochemical Analyzer
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
13-08-2024 Closed
Work Detail
The Reagent Is Used For Quantitative Measurement In Vitro Of The Concentration Of C-Reactive Protein (Crp) In Human Blood Serum On A Dirui Cs-T240 Biochemical Analyzer. They Use A Latex Particle That Is Sensitized By An Antibody Against Human C-Reactive Protein. Latex Particles Collide With C-Reactive Protein In A Liquid Sample And Form An Insoluble Antigen-Antibody Complex And A Certain Turbidity. The Level Of Turbidity Reflects The Level Of C-Reactive Protein In The Sample In Comparison With A Calibrator Processed In A Similar Way, So It Is Possible To Calculate The Concentration Of C-Reactive Protein In The Sample. Reagents: R1- Tris Buffer 20 Mmol/L. R2 - Antibody Against Human C-Reactive Protein Corresponding Quantity. The Main Wavelength Is 546 Nm. Test Time Is 2 Minutes. Volume R1 - 120 Ml. Volume R2 - 30 Ml. The Volume Of The Sample Is 2 Μl. The Mode Of Analysis Is Determination By Two Points. The Number Of Tests In The Package Is No More Than 280. The Calibrator Is Included In The Set. Control Of The Reagent Is Carried Out On Control For Specific Proteins Level 1 And 2. Calibrator And Control From The Manufacturers Factory With The Passport Values ​​Of The Control Material And The Calibrator With The Target Value. The Linear Range Of This Reagent Is 0-0.80 Mg/L. Reagents Are Supplied In Disposable Factory Packaging (Vial). The Vial Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Manufacture Of The Reagent, The Date Of The Expiration Of The Reagents Expiration Date. The Vial Barcode Must Be Compatible With The Analyzers Os And The Analyzers Security System. Contamination And Damage To The Bar Code Is Not Allowed. The Distance Between The Bottom Of The Bottle And The Bar Code Should Correspond To The Range Of 15Mm-25Mm. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For In Vitro Quantitative Determination Of Potassium (Ka) Concentration In Serum Or Plasma On The Dirui Cs-T240 Biochemical Analyzer. Potassium Is Determined By The Fermative Reaction Of Phosphoenolpyruvate Substrate Catalyzed By Potassium-Dependent Pyruvate Kinase. The Product Pyruvate Reacted With Nadh Under The Action Of Lactate Dehydrogenase To Produce Nad⁺ And Its Absorption Value Is 340 Nm. Reagents: R1-Pyruvate Of Phosphoric Acid, Diluted With Alcohol ≥ 3.0 Mmol/L; Adp -≥ 3.0 Mmol/L; Α-Ketone Glutaric Acid -≥ 1.0 Mmol/L; Nadh-≥ 0.30 Mmol/L; Pyruvate Kinase - ≥ 1.0 U/Ml. R2-Lactate Dehydrogenase -≥ 60 U/Ml. Potassium Calibration Sample = Solution Containing Potassium Ion - On The Label. Volume R1: 120 Ml. Volume R2: 20 Ml. The Sample Volume Is 5 Μl. The Time Of The Test Is 120 S. Calibration And Control In The Set. Reagent Calibration Is Also Carried Out On A Multicalibrator. Control Of The Reagent Is Carried Out On Multi-Control Level 1 And 2. Calibrator And Control From The Manufacturers Factory With The Passport Values ​​Of The Control Material And The Calibrator With The Target Value. Linearity Range: 2.10 Mmol/L. The Number Of Tests In A Package Is No More Than 474. Reagents Are Supplied In One-Time Factory Packaging (Vial). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Manufacture Of The Reagent, The Date Of The Expiration Of The Reagents Expiration Date. The Vial Barcode Must Be Compatible With The Analyzers Os And The Analyzers Security System. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Control Serum Of Specific Proteins (Level No. 1) Liquid Ready-To-Use Is Used To Assess The Accuracy And Reproducibility Of The Measurement On The Dirui Cs-T240 Biochemical Analyzer Of The Following Parameters: Iga/Igm/Igg/C3/C4/Pa/Trf/Β2-Mg/ Aso/Crp/Alb/Rbp. 1*1 Ml. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For Quantitative Measurement In Vitro Of Immunoglobulin-M (Igm) In Human Blood Serum On A Dirui Cs-T240 Biochemical Analyzer. Serum Or Plasma Is Mixed With An Antibody Against Human Igm In A Reagent, Which Leads To The Formation Of An Antigen-Antibody Complex, While A Certain Degree Of Turbidity Is Formed, The Intensity Of Which Is Directly Proportional To The Content Of Igm In The Serum. The Content Of Igm In The Serum Can Be Calculated By Measuring The Absorption Of The Turbidity At 340 Nm And Comparing It With The Standard Curve. Reagents: R1 - Buffer. R2- Solution Containing Goat Antibody Against Human Igg. The Time Of The Test Is 5 Minutes. The Volume Of R1 Is 50 Ml. The Volume Of R1 Is 10 Ml. The Volume Of The Sample Is 3 Μl. The Number Of Tests In The Package Is No More Than 112. The Calibrator Is Included In The Set. Control Of The Reagent Is Carried Out On Control For Specific Proteins Level 1 And 2. Calibrator And Control From The Manufacturers Factory With The Passport Values ​​Of The Control Material And The Calibrator With The Target Value. The Linear Range Of This Reagent Is 0.05-3 G/L. Reagents Are Supplied In Disposable Factory Packaging (Vial). The Vial Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Manufacture Of The Reagent, The Date Of The Expiration Of The Reagents Expiration Date. The Vial Barcode Must Be Compatible With The Analyzers Os And The Analyzers Security System. Contamination And Damage To The Bar Code Is Not Allowed. The Distance Between The Bottom Of The Bottle And The Bar Code Should Correspond To The Range Of 15Mm-25Mm. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. Gost R 51352-99, Control Serum Of Lipids (Level No. 1) Lyophilized Powder. It Is Used To Assess The Accuracy And Reproducibility Of Measurements On The Dirui Cs-T240 Biochemical Analyzer Of The Following Parameters: Apo A1/Apo B/Tc/Hdl-C/Ldl-C/Lp(A)/Tg\Rf. Packaging: 1 X 1 Ml. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For Quantitative Measurement In Vitro Of Immunoglobulin-A (Iga) In Human Blood Serum On A Dirui Cs-T240 Biochemical Analyzer. Serum Or Plasma Is Mixed With An Antibody Against Human Iga In A Reagent, Which Leads To The Formation Of An Antigen-Antibody Complex, While A Certain Degree Of Turbidity Is Formed, The Intensity Of Which Is Directly Proportional To The Content Of Iga In The Serum Or Plasma. The Content Of Iga In Plasma Or Serum Can Be Calculated By Measuring The Absorption Of Turbidity At 340 Nm And Comparing It With A Standard Curve. Reagents: R1 - Buffet. R2 - Solution Containing Goat Antibody Against Human Iga. The Time Of The Test Is 5 Minutes. The Volume Of R1 Is 50 Ml. The Volume Of R2 Is 10 Ml. The Volume Of The Sample Is 3 Microns. The Number Of Tests In The Package Is No More Than 112. Calibrator In The Set. Control Of The Reagent Is Carried Out On Control For Specific Proteins Level 1 And 2. Calibrator And Control From The Manufacturers Factory With The Passport Values ​​Of The Control Material And The Calibrator With The Target Value. The Linear Range Of This Reagent Is 0.08-6.0 G/L. Reagents Are Supplied In Disposable Factory Packaging (Vial). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Manufacture Of The Reagent, The Date Of The Expiration Of The Reagents Expiration Date. The Vial Barcode Must Be Compatible With The Analyzers Os And The Analyzers Security System. Contamination And Damage To The Barcode Is Not Allowed. The Distance Between The Bottom Of The Bottle And The Bar Code Should Correspond To The Range Of 15Mm-25Mm. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. Gost R 51352-99, The Reagent Is Used For Quantitative Measurement In Vitro Of The Concentration Of Low-Density Lipoprotein Cholesterol (Ldl-C) Contained In Human Blood Serum On A Dirui Cs-T240 Biochemical Analyzer. Cholesterol Of Low-Density Lipoproteins In The Sample Under The Influence Of Surfactants In The Reagent Is Selectively Catalyzed And Hydrolyzed By Cholesterol Esterase Into Cholesterol And Free Fatty Acid. Components: Reagent 1 - 4-Aminoantipyrine 1 Mmol/L; Cholesterol Oxidase 500 Units/L; Cholesterol Esterase 800 Units/L; Peroxidase 800 Units/L; Nonionic Surfactant 0.5% Polymer Compound Necessary Quantity; Mops Buffer 100 Mmol/L. Reagent 2- Dsbmt 1.2%; Nonionic Surfactant 0.5%; Mops Buffer 100 Mmol/L. The Time Of The Test Is 300 Seconds. Volume R1-150 Ml. Volume R2-50 Μl. Sample Volume-4 Μl. The Number Of Tests In The Package Is No More Than 366. The Calibrator Is Included In The Set. Control Of The Reagent Is Carried Out For Control Of Lipids Level 1 And 2. Calibrator And Control From The Manufacturers Factory With The Passport Values ​​Of The Control Material And The Calibrator With The Target Value. The Linear Range Of This Reagent Is 0-450 Mg/Dl. Reagents Are Supplied In Disposable Factory Packaging (Vial). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Manufacture Of The Reagent, The Date Of The Expiration Of The Reagents Expiration Date. The Vial Barcode Must Be Compatible With The Analyzers Os And The Analyzers Security System. Contamination And Damage To The Barcode Is Not Allowed. The Distance Between The Bottom Of The Bottle And The Bar Code Should Correspond To The Range Of 15Mm-25Mm. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For Quantitative Measurement In Vitro Of The Concentration Of High-Density Lipoprotein Cholesterol (Hdl-C) Contained In Human Blood Serum On A Dirui Cs-T240 Biochemical Analyzer. Cholesterol Of High-Density Lipoproteins In The Sample Under The Influence Of Surfactants In The Reagent Is Selectively Catalyzed And Hydrolyzed By Cholesterol Esterase Into Cholesterol And Free Fatty Acid. Components: R1 - 4-Aminoantipyrine 1 Mmol/L; Cholesterol Oxidase 1 Cad/L; Cholesterol Esterase 1 Cad/L; Peroxidase 4 Cad/L; Nonionic Surfactant 0.5%; Polymer Connection Necessary Quantity; Mops Buffer 100 Mmol/L. R2 - Dsbmt 1.2%; Nonionic Surfactant 0.5%; Mops Buffer 100 Mmol/L. The Time Of The Test Is 300 Seconds. Volume R1-150 Ml. Volume R2-50 Ml. The Volume Of The Sample Is 4 Μl. The Number Of Tests In The Package Is No More Than 366. The Calibrator Is Included In The Set. Control Of The Reagent Is Carried Out On Control For Lipids Level 1 And 2. Calibrator And Control From The Manufacturers Factory With The Passport Values ​​Of The Control Material And The Calibrator With The Target Value. The Linear Range Of This Reagent Is 0-150 Mg/Dl. Reagents Are Supplied In Disposable Factory Packaging (Vial). The Vial Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Manufacture Of The Reagent, The Date Of The Expiration Of The Reagents Expiration Date. The Vial Barcode Must Be Compatible With The Analyzers Os And The Analyzers Security System. Contamination And Damage To The Bar Code Is Not Allowed. The Distance Between The Bottom Of The Bottle And The Bar Code Should Correspond To The Range Of 15Mm-25Mm. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For Quantitative Measurement In Vitro Of The Concentration Of Albumin (Alb) In The Serum Or Plasma Of Human Blood On The Dirui Cs-T240 Biochemical Analyzer. The Method Used To Analyze Albumin In Blood Serum Is The Lysine Dye Binding Method (Dbl). The Dbl Technology Is Based On The Transfer Of The Largest Absorption Peak When The Dye Binds To Albumin. The Transfer Of The Absorption Peak Makes It Possible To Measure The Resulting Color In The Presence Of Excessive Staining. Accuracy Is Ensured By The Presence Of A Joint Ability Between The Dye And Albumin, Which Fully Integrates Albumin Into The Reaction. The Use Of Bromocresol Green And Albumin At Ph4.0~4.2 Causes The Formation Of A Greenish-Blue Combination, Which Is Directly Dependent On The Concentration Of Albumin In The Sample. The Concentration Of Albumin Can Be Calculated By Measuring The Absorption Value At 580-630 Nm. When Using A Double Beam Of Light, The Length Of The Idle Wave Can Be Set To 600~700Nm. Components: Bromohexal Green 0.35 Mmol/L; Succinic Acid Buffer 50 Mmol/L; Sodium Azide 7.7 Mmol/L; Brij-35 1%. Test Time Is 300 Seconds. Volume R1-250 Ml. The Volume Of The Sample Is 2 Μl. The Number Of Tests In The Package Is No More Than 730. The Calibrator Is Included In The Set. Reagents Are Supplied In Disposable Factory Packaging (Vial). The Vial Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Manufacture Of The Reagent, The Date Of The Expiration Of The Reagents Expiration Date. The Vial Barcode Must Be Compatible With The Analyzers Os And The Analyzers Security System. Contamination And Damage To The Bar Code Is Not Allowed. The Distance Between The Bottom Of The Bottle And The Bar Code Should Correspond To The Range Of 15Mm-25Mm. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For Quantitative Measurement In Vitro Of Immunoglobulin-G (Igg) In Human Blood Serum On The Dirui Cs-T240 Biochemical Analyzer. Serum Or Plasma Is Mixed With An Antibody Against Human Igg In A Reagent, Which Leads To The Formation Of An Antigen-Antibody Complex, While A Certain Degree Of Turbidity Is Formed, The Intensity Of Which Is Directly Proportional To The Content Of Igg In The Serum. The Content Of Igg In The Serum Can Be Calculated By Measuring The Absorbance Of The Turbidity At 700 Nm And Comparing It With The Standard Curve. Reagents: R1: Buffer. R2: Solution Containing Goat Antibody Against Human Igg. The Time Of The Test Is 5 Minutes. The Volume Of R1 Is 50 Ml. Volume R2-10 Ml. The Volume Of The Sample Is 2 Μl. The Number Of Tests In The Package Is No More Than 100. The Calibrator Is Included In The Set. Control Of The Reagent Is Carried Out On Control For Specific Proteins Level 1 And 2. Calibrator And Control From The Manufacturers Factory With The Passport Values ​​Of The Control Material And The Calibrator With The Target Value. The Linear Range Of This Reagent Is 0.08-6.0 G/L. Reagents Are Supplied In Disposable Factory Packaging (Vial). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Manufacture Of The Reagent, The Date Of The Expiration Of The Reagents Expiration Date. The Vial Barcode Must Be Compatible With The Analyzers Os And The Analyzers Security System. Contamination And Damage To The Barcode Is Not Allowed. The Distance Between The Bottom Of The Bottle And The Bar Code Should Correspond To The Range Of 15Mm-25Mm. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Lipid Control Serum (Level #2) Lyophilized Powder. It Is Used To Assess The Accuracy And Reproducibility Of Measurements On The Dirui Cs-T240 Biochemical Analyzer Of The Following Parameters: Apo A1/Apo B/Tc/Hdl-C/Ldl-C/Lp(A)/Tg\Rf. Packaging: 1 X 1 Ml. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For In Vitro Quantitative Determination Of Sodium (Na) Concentration In Serum Or Plasma On The Dirui Cs-T240 Biochemical Analyzer. O-Nitrophenol Β-D-Galactopyrano Is Catalyzed By Sodium Dependent Β-Galactosidase. O-Nitrophenol Absorbs At 405 Nm In Direct Proportion To The Sodium Ion Concentration. Reagents: R1-- Β-Galactoside ≥0.70 U/Ml; R2- O-Nitrophenol Β-D-Galactopyran-≥ 5.2 Mmol/L. Calibration Sample - Solution Containing Sodium Ions - On The Label. Volume R1: 120 Ml. Volume R2: 40 Ml. The Sample Volume Is 8 Μl. The Time Of The Test Is 120 S. The Number Of Tests In The Package Is No More Than 474. Calibration And Control In The Set. Reagent Calibration Is Also Carried Out On A Multicalibrator. Control Of The Reagent Is Carried Out On Multi-Control Level 1 And 2. Calibrator And Control From The Manufacturers Factory With The Passport Values ​​Of The Control Material And The Calibrator With The Target Value. Linearity Range: 80-180 Mmol/L. Reagents Are Supplied In Disposable Factory Packaging (Vial). The Vial Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Manufacture Of The Reagent, The Date Of The Expiration Of The Reagents Expiration Date. The Vial Barcode Must Be Compatible With The Analyzers Os And The Analyzers Security System. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Control Serum Of Specific Proteins (Level No. 2) Liquid, Ready-To-Use, Is Used To Assess The Accuracy And Reproducibility Of Measurements On The Dirui Cs-T240 Biochemical Analyzer Of The Following Parameters: Iga/Igm/Igg/C3/C4/Pa/Trf/Β2-Mg/Aso /Crp/Alb/Rbp. 1*1 Ml. An Accompanying Service Is Included In The Purchase Of Goods: The Visit Of A Certified Specialist For The Adaptation Of The Reagent. For Additional Equipment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99
Key Value
Tender Value
5,506,353 - KZT
Tender Documents
Global Tender Document
860e8722-9589-4056-82ff-95b4b5479b72.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders