GTR 83892878

Request For Quotation Purchase Of Goods For The Fire Alarm System

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
83892878
Tendering Authority
Subscribe to view
Tender No
12833540
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Goods For The Fire Alarm System
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
12-08-2024 Closed
Work Detail
Kspv Cable 2*0.4, Signal Cable For Security Systems, Monolithic Kspv - A Common Twist Cable With Single-Wire Copper Cores With A Diameter Of 0.4 Mm, With Insulation Made Of Polyethylene Composition, With A Sheath Made Of White Pvc Plastic. Construction The Current-Conducting Core Is Copper Single-Wire Insulation - Solid Polyethylene The Core Is A Common Twist The Shell Is Pvc Plastic Design Parameters Number Of Veins: 2 The Diameter Of The Vein: 0.4 Mm Number And Diameter Of Wires: 1X0.40 Core Cross-Section: 0.12 Square Mm Insulation Diameter: 0.85 Mm Cable Diameter: 2.1X2.7 Mm Weight Of 1 Km Of Cable: 7.77 Kg Fuel Volume: 4.2 L/Km Volume Of 1 Km Of Cable: 0.0129M3 The Electrical Resistance Of Current-Carrying Wires To Direct Current At 20Oc And 1 Km Long Is No More Than 148.0 Ohm/Km. Insulation Resistance For A Length Of 1 Km At A Temperature Of 20°C And Normal Relative Humidity, Not Less Than 6500 Mω, Electrical Capacity For Unshielded Cables Of Kspv Brand Circuits, No More Than 60 Nf/Km: Core - Core, Reception And Control Device Number Of Supported Loops 8 Minimum Working Temperature -30 Degrees. Maximum Working Temperature 50 Degrees Length 240 Mm Width 83.5 Mm Height 200 Mm Features: Overall Dimensions (L*H*W): 240X200x83.5 Mm. Operating Temperature Range: From -30°C To +50°C. Body Material: Plastic. Nominal Resistance Of The Remote Resistor: 7.5 Kω. Number Of Programmable Identifiers: 255. Number Of Loops: 8. Mode Control Method: Button, Tm Key. Number Of Sections: 2. The Possibility Of Installing A Battery: 4.5 A/H., Izveshatel Fire Alarm Maximum Technical Characteristics The Polarity Of The Supply Voltage Is Arbitrary The Nominal Operating Temperature Is +64...+76 °C Time Of Activation When The Temperature Rises At A Rate Of 3 °С/Min* 770 ±190 S The Interval Between Temperature Measurements Is 6...8 S The Time To Return To The Standby Mode After Removing The Power Supply, Not Less Than 2 Seconds The Working Voltage Of The Mains, Not More Than 10...25 V The Permissible Loop Closing Current In Alarm Mode Is No More Than 20 Ma The Current Consumption Is 60 Μa Final Voltage In Fire Mode (Internal), No More Than 5.5 V Degree Of Protection, Not Less Than Ip30 Operating Temperature Range -30...+76 °C Average Time To Failure, Not Less Than 70,000 Hours Service Life, 10 Years Overall Dimensions: Height / Diameter, No More Than 34 Mm / 62 Mm, The Fire Alarm Light Is Intended For Installation In The Interior Of Industrial Enterprises, Civil Buildings And Is Designed For The Purpose Of Light Notification Of Fire Or Other Emergency Situations, As Well As For Various Informational Purposes. Features White Candle Board, Made Using Leds. Power Supply Voltage, V 12 Degree Of Protection Ip52 Current Consumption, Ma 20 Overall Dimensions. Mm 302X102x20 Time Of Continuous Operation In Alarm Mode, Min. Not Limited Mass, Not More, Kg 0.20, Manual Fire Alarm Type Of Detector 2-Wire - In Fire Mode 20 Light Indication Duty Mode; Fire Overall Dimensions. Mm 92X95x33 Supply Voltage, B: Degree Of Protection Ip41 - On The Alarm Loop 9...30 Operating Temperature Range, °С -30...+55 Consumption Current, Ma: Mass, Not More, Kg 0.07 - No More In Standby Mode 0.025, Reception And Control Device Number Of Supported Loops 24 General Minimum Working Temperature -30 Degrees. Maximum Working Temperature 50 Degrees Length 312 Mm Width 94 Mm Height 214 Mm Features: Overall Dimensions (L*H*W): 312X214x94 Mm. Operating Temperature Range: From -30°C To +50°C. Body Material: Plastic. Nominal Resistance Of The Remote Resistor: 7.5 Kω. Number Of Programmable Identifiers: 255. Number Of Loops: 24. Mode Control Method: Button, Tm Key. Number Of Sections: 8. The Possibility Of Installing A Battery: 7 A/H., Accumulator Battery 13.5-13.8V For Security Alarm Nominal Voltage: 12 V (6 Cells Per Block) Capacity: 7.2 Ah With A 20-Hour Discharge To U Con. - 1.75 V/L At 25 °C Weight: 2.6 Kg Maximum Discharge Current: 100/130 A (5 Sec) Internal Resistance: 22.0 Mω Operating Temperature Range: Discharge: From -15 °C To +50 °C Charge: From -15 °C To +40 °C Storage: From -15 °C To +40 °C Short Circuit Current: 265 A Nominal Working Temperature: 25 °C Charge Voltage: 13.5 - 13.8 V At 25 °C Maximum Charge Current: 2.16 A (When Charging With A Constant Current), In The Mode Of Constant Undercharging, I Max Is Not Limited Charge Voltage In Cyclic Mode: 14.4 - 15.0 V At 25 °C Self-Discharge: Less Than 10% For 90 Days. It Can Be Stored Without Recharging For More Than 6 Months At +25 °C, Reception And Control Device Fire Protection, Number Of Supported Loops 16 General Minimum Working Temperature -30 Degrees. Maximum Working Temperature 50 Degrees Length 312 Mm Width 94 Mm Height 214 Mm Features: Overall Dimensions (L*H*W): 312X214x94 Mm. Operating Temperature Range: From -30°C To +50°C. Body Material: Plastic. Nominal Resistance Of The Remote Resistor: 7.5 Kω. Number Of Programmable Identifiers: 255. Number Of Loops: 16. Mode Control Method: Button, Tm Key. Number Of Sections: 8. The Possibility Of Installing A Battery: 7 A/H., Reception And Control Device Number Of Supported Loops 4 General Minimum Working Temperature -30 Degrees. Maximum Working Temperature 50 Degrees Length 240 Mm Width 83.5 Mm Height 200 Mm Features: Overall Dimensions (L*H*W): 240X200x83.5 Mm. Operating Temperature Range: From -30°C To +50°C. Body Material: Plastic. Nominal Resistance Of The Remote Resistor: 7.5 Kω. Number Of Programmable Identifiers: 255. Number Of Loops: 4. Mode Control Method: Button, Tm Key. Number Of Sections: 2. The Possibility Of Installing A Battery: 4.5 A/H., The Annunciator Is Intended For Light And Sound Notification Of The State Of The Object, Which Is Protected With The Help Of Fire Alarm Devices. Technical Characteristics: Dc Power Supply Voltage, V 12 Nominal Current Consumption, Ma Light Announcer 25 Sound Announcer 50 Sound Pressure Level, Db, Not Less Than 105 The Time Of Continuous Operation In Alarm Mode Is Not Limited Degree Of Protection Of The Shell, Ip 55 Overall Dimensions, Mm 100 X 80 X 42 Mass, Kg, No More Than 0.06 Operating Temperature Range, ºс -30...+55 Relative Air Humidity At +25 ºс, %, No More Than 95, Optical-Electronic Point Fire Detector. Technical Characteristics: Power Supply Voltage, 9 To 30 V Current Consumption In Standby Mode, Μa, No More Than 45 Sensitivity, Db/M From 0.05 To 0.2 Inertia Of Activation, Sec, Not More Than 9 Installation Type On The Main Ceiling Internal Resistance In Fire Mode, No More Than 1000 Ohms Optical Status Indicator Red The Method Of Testing With A Needle Through A Technological Hole Degree Of Hardness To Electromagnetic Interference 3 The Degree Of Protection Of The Shell Is Ip30 The Mass Of The Detector With The Basic Base, G, No More Than 210 The Diameter Of The Detector With The Basic Base, Mm, No More Than 94 The Height Of The Detector With The Basic Base, Mm, No More Than 46 Warranty Period Of Operation, Months, No More Than 24 Average Service Life, 10 Years Operating Temperature Range, °C From -30 To +55
Key Value
Tender Value
6,141,920 - KZT
Tender Documents
Global Tender Document
60cc115f-cc81-4521-ae44-008f9c69f80c.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders