GTR 82575975
Request For Quotation Purchase Of Medical Products, Astana - Products Will Be Accepted Strictly !
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
82575975
Tendering Authority
Subscribe to view
Tender No
12698727
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Medical Products, Astana - Products Will Be Accepted Strictly !
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
15-07-2024
Closed
Work Detail
Intrauterine Contraceptive With Copper The Anchor Of The Intrauterine Contraceptive Is Made Of Plastic. The Shape Of The Anchor Is T-Shaped. A Copper Wire With A Nominal Active Surface Area Of 380 Mm2 Is Wound On The Vertical Rod Of The Anchor (The Purity Of Copper Is At Least 99.98%), And A Monofilament Thread Is Attached To Control The Location And Extraction Of The Contraceptive. X-Ray And Ultrasound - Contrast Is Provided By The Presence Of A Copper Wire On The Rod., Obstetric Unloading Silicone Pessary, Type 1 Pessary Type 1 Is Intended For The Prevention Of Premature Labor In Isthmic-Cervical Insufficiency. Made Of Medical Silicone, It Ensures The Elasticity Of The Pessary, Facilitating Its Installation; Does Not Cause Painful Sensations And Discomfort When Used; Absolutely Safe For The Body Of The Mother And Child; Reduces The Risk Of Irritating Effects On The Mucous Membrane Of The Vagina., Ring-Shaped Intrauterine Contraceptive Device, Type 1 The Anchor Of The Intrauterine Contraceptive Is Made Of Plastic In The Form Of A Closed Ring With A Diameter Of 19 Mm, Inside Which A Rod Is Placed. A Bimetallic Copper-Silver Wire With A Nominal Active Surface Area Of 255 Mm2 (Copper Purity - Not Less Than 99.98%, Silver Content Not Less Than 9.3%) Is Wound On The Rod And A Monofilament Thread Is Attached To Control The Placement And Extraction Of The Contraceptive. X-Ray And Ultrasound Contrast Is Ensured By The Presence Of A Bimetallic Copper-Silver Wire On The Rod., Type 3 Obstetric Pessary Type 3 Obstetric Pessary. They Are Used In Obstetric Practice To Prevent Premature Births In Isthmic-Cervical Insufficiency (Icn). A Pessary Is A Plastic Device In The Shape Of A Trapezoid With Rounded Corners. The Shape Of The Pessary Provides Effective Pressure Reduction On The Cervix., Type 2 Obstetric Pessary Type 2 Obstetric Pessary. They Are Used In Obstetric Practice To Prevent Premature Births In Isthmic-Cervical Insufficiency (Icn). A Pessary Is A Plastic Device In The Shape Of A Trapezoid With Rounded Corners. The Shape Of The Pessary Provides Effective Pressure Reduction On The Cervix., Obstetric Unloading Silicone Pessary, Type 3 Pessary Type 3 Is Intended For The Prevention Of Premature Labor In Isthmic-Cervical Insufficiency. Made Of Medical Silicone, It Ensures The Elasticity Of The Pessary, Facilitating Its Installation; Does Not Cause Painful Sensations And Discomfort When Used; Absolutely Safe For The Body Of The Mother And Child; Reduces The Risk Of Irritating Effects On The Mucous Membrane Of The Vagina., Obstetric Pessary According To Types No. 1 Obstetric Pessary Type 1. Used In Obstetric Practice For The Prevention Of Premature Labor In Isthmic-Cervical Insufficiency (Icn). A Pessary Is A Plastic Device In The Shape Of A Trapezoid With Rounded Corners. The Shape Of The Pessary Provides Effective Pressure Reduction On The Cervix., Single-Use Sterile Probe, Cytobrush Disposable Instrument For Taking Material. The Presence Of Soft Elastic Bristles On The Working Part Of The Cytobrush Allows You To Collect A Large Amount Of Material For Various Types Of Research. Cytobrush Provides A Representative Atraumatic Sampling Of The Material. If Necessary, The Working Part Can Be Bent At Any Angle Relative To The Handle. The Probe Must Be Hermetically Packed In A Sterilizing (Final) Individual Package Of The Type Of Paper-Film Bag Or Blister Package Using Water-Repellent Medical Paper With A Density Of At Least 55 G/M2 (Non-Transparent Side) Connected By A Continuous Thermal Seam With A Transparent Multilayer Polymer Film With A Thickness Of At Least 60 Microns (Transparent Side)., Ring-Shaped Intrauterine Contraceptive Device, Type 1 The Anchor Of The Intrauterine Contraceptive Device Is Made Of Plastic In The Form Of A Closed Ring With A Diameter Of 19 Mm. A Copper Wire With A Nominal Active Surface Area Of 374 Mm2 (Purity Of Copper - At Least 99.98%) Is Wound On The Rod, And A Monofilament Thread Is Attached To Control The Location And Extraction Of The Contraceptive. X-Ray And Ultrasound Contrast Is Ensured By The Presence Of A Copper Wire On The Rod. The Method Of Introducing The Iud Is The Withdrawal Method, The Diameter Of The Graduated Tube-Conductor Is 3.9 Mm. The Duration Of Contraception Is No More Than 3 Years. Gas Sterilization. The Contraceptive Is Delivered Sterile In The Final Package, Which, Together With The Instructions For Use, Is Placed In The Secondary Package., Aspiration Gynecological Tube, Single-Use, Sterile, Diameter 6 Mm Aspiration Gynecological Tubes: 6.0 Mm Aspiration Gynecological Tubes Are Polymer Translucent Tubes 215 Mm Long, 6.0 Mm In Diameter. A Longitudinal Groove 30 Mm Long And 2.7 Mm Wide Is Made At The Distal End Of The Tubes. The Edges Of The Groove Are Rounded And Smoothed. The Instrument Is Supplied Sterile And Ready For Use., Obstetric Unloading Silicone Pessary, Type 2 Pessary Type 2 Is Intended For The Prevention Of Premature Labor In Isthmic-Cervical Insufficiency. Made Of Medical Silicone, It Ensures The Elasticity Of The Pessary, Facilitating Its Installation; Does Not Cause Painful Sensations And Discomfort When Used; Absolutely Safe For The Body Of The Mother And Child; Reduces The Risk Of Irritating Effects On The Mucous Membrane Of The Vagina., Intrauterine Contraceptive The Anchor Of The Intrauterine Contraceptive Is Made Of Plastic. The Shape Of The Anchor Is T-Shaped. A Bimetallic Copper-Silver Wire With A Nominal Active Surface Area Of 380 Mm2 Is Wound On The Vertical Rod Of The Anchor (The Purity Of Copper Is At Least 99.98%, The Content Of Silver Is Not Less Than 9.3%), And A Monofilament Thread Is Fixed To Control The Location And Extraction Of The Contraceptive . X-Ray And Ultrasound Contrast Is Ensured By The Presence Of A Bimetallic Copper-Silver Wire On The Rod., Probe Sterile Disposable Aspiration Tool Consists Of A Flexible Transparent Tube With A Diameter Of 3 Mm. At The Distal, Atraumatically Rounded End Of The Tube, There Are Working Holes. A Plastic Piston With A Sealing Ring Is Placed Inside The Tube. To Determine The Length Of The Uterine Cavity, A Measuring Scale Is Applied To The Tube. The Design Of The Tool Allows You To Take Material Samples In A Few Minutes, Without Resorting To Dilation Of The Cervical Canal. The Tool Consists Of An Elastic Transparent Tube With A Diameter Of 3±0.2 Mm. There Are 2 Working Holes On The Atraumatically Rounded End Of The Tube. A Plastic Piston With A Sealing Ring Is Placed Inside The Tube. The Total Length Of The Tool Is 300±10 Mm. The Length Of The Tube Is 240±10 Mm., Ring-Shaped Intrauterine Contraceptive Device, Type 2 The Anchor Of The Intrauterine Contraceptive Is Made Of Plastic In The Form Of A Closed Ring With A Diameter Of 24 Mm, Inside Which A Rod Is Placed. A Bimetallic Copper-Silver Wire With A Nominal Active Surface Area Of 374 Mm2 (Copper Purity - Not Less Than 99.98%, Silver Content Not Less Than 9.3%) Is Wound On The Rod And A Monofilament Thread Is Attached To Control The Placement And Extraction Of The Contraceptive. X-Ray And Ultrasound - Contrast Is Provided By The Presence Of A Bimetallic Copper-Silver Wire On The Core.
Key Value
Tender Value
1,680,400 - KZT
Tender Documents
Global Tender Document
2e3ac280-8ef0-41c3-993b-c505e4a3efee.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.