GTR 82510438

Tenders Are Invited For Calibrators And Consumables For A Modular Analyzer (Cobas 6000 Module With 501 Biochemistry) For 2024

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
82510438
Tendering Authority
Subscribe to view
Tender No
12691669
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Calibrators And Consumables For A Modular Analyzer (Cobas 6000 Module With 501 Biochemistry) For 2024
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
12-07-2024 Closed
Work Detail
Calibrator Universal For Biochemical Systems (Cfas), 12 Vials With Lyophilized Material For Preparation Of 3 Ml Of Liquid Calibrator In Each. Purpose: Calibrator For Automated Systems C.F.A.S. Intended For Calibration Of Clinical Tests On Cobas C And Cobas Integra Analyzers. Reagents And Working Solutions: Reactive Components In Lyophilisate: Human Blood Serum With Chemical Additives And Material Of Biological Origin In Accordance With The Specified Data. Biological Supplements Have The Following Origin: Alt (Hpt) - Pig Heart, Ast (Hot) - Human, Recombinant, Acid Phosphatase - Human Prostate Gland/Potato, Albumin - Bull Blood Plasma, Aldolase - Rabbit Muscle Tissue, Alkaline Phosphatase - Human Placenta (Recombinant), Amylase - Pig Pancreas, Cholesterol - Bull Blood Plasma, Cholinesterase - Human Serum, Creatine Kinase - Rabbit Muscle Tissue, Ld (Ldh) - Pig Heart, Lipase - Human Pancreas (Recombinant), Triglycerides - Chicken Egg Yolk. Non-Reactive Components: Stabilizers. The Concentrations And Action Of The Calibrator Components Are Determined Separately For Each Batch Of Goods. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 2 Days, At (-15)‑(-25) °C 4 Weeks (With Single Freezing). Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Control Of Glycosylated Hemoglobin Norm (Precicontrol Hba1c Norm), 4 Vials Of Liquid Ready-To-Use Control Material. Purpose: The Set Is Intended For Use During Quality Control Procedures, As It Allows Determining The Accuracy Of Quantitative Methods Specified In Special Documents. Reagents And Working Solutions: Reactive Components In Liquid Control Material: Hemolyzed Human Blood. The Concentration Values ​​Of The Components Are Specific For Each Particular Lot. The Exact Target Values ​​Are Given In The Available Electronic Form Or The Attached Value Passports. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 2 Days, At (-15)‑(-25) °C 4 Weeks (With Single Freezing). Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Calibrator Iron Standard, 1 Bottle With Solid Ready-To-Use Calibrator, Volume 75 Ml. Purpose: The Fe Standard (Iron Standard) Calibrator Is Intended For The Calibration Of Quantitative Tests To Determine The Unsaturated Iron-Binding Capacity Of Blood Serum On Roche Biochemical Analyzers. Reactive Components: Iron Ammonium Alum 0.09 Mmol/L. Non-Reactive Components: Dilute Sulfuric Acid. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 2 Days. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Glycolized Hemoglobin Calibrator Cfas Hba1c, 3 Vials With Lyophilized Material For The Preparation Of 1 Ml Of Liquid Calibrator In Each. Appointment: C.F.A.S. Hba1c (Calibrator For Automatic Systems) Is Used To Calibrate Roche Quantitative Tests On Analyzers For Roche Clinical Chemistry According To The Attached Passports Of Assigned Values. As Stipulated In The Attached Special Documents. Reagents - Working Solutions: Active Components: Hemolyzed Sheep Blood With Chemical Additives And Material Of Biological Origin, In Accordance With The Specified Data Biological Supplements Have The Following Origin: Hemoglobin - Sheep Blood, Hba1c - Human Blood. Inactive Components: Stabilizers And Preservatives. The Concentrations Of The Calibrator Components Are Specific To The Lot. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 2 Days, At (-15)‑(-25) °C 4 Weeks (With Single Freezing). Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Calibrator For Lipids (Cfas Lipids), 3 Vials With Lyophilized Material For Preparation Of 1 Ml Of Liquid Calibrator In Each. Purpose: The Calibrator For Automated Systems Is Intended For The Calibration Of Roche Tests For The Quantitative Determination Of One Or More Proteins Of Roche Clinical Chemistry, In Accordance With The Passports Of The Assigned Values. Reagents And Working Solutions: Reactive Components In Lyophilisate: Human Serum With Chemical Additives. Non-Reactive Components: Preservative And Stabilizer. The Concentrations Of The Calibrator Components Are Determined Separately For Each Series. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 2 Days, At (-15)‑(-25) °C 4 Weeks (With Single Freezing). Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Rheumafactor Calibrator (Preciset Rf), 5 Vials With Liquid Ready-To-Use Calibrator Volume 1 Ml. Each Vial Has A Different Concentration Of The Calibrator. Purpose: The Calibrator For Automated Systems Is Intended For The Calibration Of Roche Tests For The Quantitative Determination Of One Or More Proteins Of Roche Clinical Chemistry, In Accordance With The Passports Of The Assigned Values. Reagents And Working Solutions: Reactive Components: Rf In Human Blood Serum. Non-Reactive Components: Hepes Buffer, Bovine Serum Albumin, Sodium Chloride, Preservative. Concentrations Of Components Are Specific For Each Lot. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C For 8 Hours, At 2‑8 °C For 2 Days, Do Not Freeze. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Hemolyzing Solution For Glycated Hemoglobin (Hba1c Tq Haemolyzing Rgt, (Whole Blood)) 44 Ml. Purpose: The Hemolyzing Reagent Is Used As A Diluent When Performing The Tina-Quant Hemoglobin A1c Gen.3 Test On The Cobas C System. Hemolyzing Reagent Is Used For Dilution Of Whole Of Blood Samples (When Using Whole Blood Samples), As Well As For Diluting The Calibrator (When Using Whole Blood Samples And Hemolysate). Hemolyzing Reagent A1cd2 Hemolyzing Reagent Gen.2 Is In A Fourfold Concentrated State And Is Automatically Diluted By The Analyzer Before Use. Reagents - Working Solutions: Water Matrix With Buffer, Ph 7.25; Ttab: 36 G/L; Phosphate Buffer: 80 Mmol/L; Stabilizer; Preservative The Reagent Is Located In Positions B And C. Storage And Transportation Conditions: Store In A Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used Onboard The Analyzer At 10-15°C 4 Weeks. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Calibrator For Automatic Systems S. F.A.S. Pac, 3 Vials With Lyophilized Material For The Preparation Of 1 Ml Of Liquid Calibrator In Each. Appointment: C.F.A.S. (Calibrator For Automatic Systems) Pac (Prealbuminaslo-Ceruloplasmin) Is Intended For Use During The Application Of Roche Quantitative Methods When Working With Analyzers For Roche Clinical Chemistry. Reagents And Working Solutions: Reactive Components In Lyophilisate: Human Blood Serum With Chemical Additives And Material Of Biological Origin In Accordance With The Specified Data. Biological Supplements Have The Following Origin: Antistreptolysin O - Sheep. Non-Reactive Components: Preservative And Stabilizer. The Concentrations Of The Calibrator Components Are Determined Separately For Each Batch. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 2 Days, At (-15)‑(-25) °C 4 Weeks (With Single Freezing). Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Control Of Glycosylated Hemoglobin Norm (Precicontrol Hba1c Path), 4 Vials Of Liquid Ready-To-Use Control Material. Purpose: The Set Is Intended For Use During Quality Control Procedures, As It Allows Determining The Accuracy Of Quantitative Methods Specified In Special Documents. Reagents And Working Solutions: Reactive Components In Liquid Control Material: Hemolyzed Human Blood. The Concentration Values ​​Of The Components Are Specific For Each Particular Lot. The Exact Target Values ​​Are Given In The Available Electronic Form Or The Attached Value Passports. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 2 Days, At (-15)‑(-25) °C 4 Weeks (With Single Freezing). Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Calibrator For Proteins (Cfas Proteins), 5 Vials With Lyophilized Material For The Preparation Of 1 Ml Of Liquid Calibrator In Each. Purpose: The Calibrator For Automated Systems Is Intended For The Calibration Of Roche Tests For The Quantitative Determination Of One Or More Proteins Of Roche Clinical Chemistry, In Accordance With The Passports Of The Assigned Values. Reagents And Working Solutions: Active Components: Human Blood Serum Using Chemical Additives And Material Of Biological Origin In Accordance With The Specified Data. Biological Supplements Have The Following Origin: Ferritin - Human, Crp - Human, Antistreptolysin O - Sheep. Non-Reactive Components: Preservatives And Stabilizer. The Concentrations Of The Calibrator Components Are Specific To The Series. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 2 Days, At (-15)‑(-25) °C 4 Weeks (With Single Freezing). Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Control Rheumofactor Ii (Rf Ii Control Set), 4 Vials With Liquid Ready-To-Use Control Material Of 1 Ml Each. In A Set Of 2 Vials For The Concentration Of Low Values ​​For Level I And High Values ​​For Level Ii. The Rf Control Set Is Intended For Use During Quality Control Procedures, As It Allows Determining The Accuracy Of Quantitative Methods Specified In Special Documents. Reagents And Working Solutions: Reactive Components: Human Blood Serum With Chemical Additives And Material Of Biological Origin In Accordance With The Specified Data. Origin Of Biological Supplements: Rf - Человек. Non-Reactive Components: Hepes Buffer, Bovine Serum Albumin, Sodium Chloride, Preservative. Concentrations Of Control Materials Are Specific For A Particular Lot. Storage And Transportation Conditions: Store In The Refrigerator. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 2 Days, At (-15)‑(-25) °C 4 Weeks (With Single Freezing). Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas C 501 Analyzer. The Supplier Must Provide A Certificate Of Product Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer.
Key Value
Tender Value
742,597 - KZT
Tender Documents
Global Tender Document
61d4c7a4-a06b-412b-9c87-9bbd5c009785.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders