GTR 82078672
Request For Quotation Purchase Of Necessary Materials For Reconstruction Of External Infrastructure
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
82078672
Tendering Authority
Subscribe to view
Tender No
12640257
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Necessary Materials For Reconstruction Of External Infrastructure
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
02-07-2024
Closed
Work Detail
Apparatus Press Clamp With Two Holes In The Contact Leg And With A Galvanic Coating Of The Contact Surface, Type A2a 50G-1 For Connecting One Aluminum Or Steel-Aluminum Wire To The Terminals Of The Apparatus. Clamps Meet The Requirements Of Tu 3449-022-84716711-2009., Electra Warning Tape For Underground Utilities Measuring 100 M X 0.15 M, Eye Type U1-7-16 Single-Lobed They Are Intended For Connecting The Rod Of A Suspension Insulator Or An Earring With Another Linear Armature. The Socket Of The Spherical Joint Connection Of The Lugs And The Connecting Dimensions Of The Lugs Correspond To Gost 11359-75, Gost 27396-93, Respectively. The Lugs Are Equipped With W-Shaped Locks For Locking The Insulator Rod Or Earring Pistil., Corner Steel Hot-Rolled Equal Shelf Made Of Carbon Steel Gost 535-2005 Shelf Width From 40 To 125 Mm, Thickness From 2 To 16 Mm, End Cable Coupling For 3-Core Cables With Paper-Impregnated Insulation For A Voltage Of 10 Kv Gek-10Knt-3-70/120-Sl-M, Support Linear Pin Glass Insulator For A Voltage Of 1-35 Kv Gost 1232-93 Type Shs 10-D Minimum Mechanical Destructive Load, Kn-13, Breakdown Voltage In The Insulating Medium, Kv-160, Leakage Path Length, Mm-280, Building Height, Mm-145, Weight, Kg-1.9., Earring Type Srs-7-16 Tu 3449-012-40064547-01 Product Dimensions - 106.9 X 57 X 17 Mm, Breaking Load - Not Less Than 70 Kn. The Outer Diameter Of The Ring Is 57 Mm, The Inner Diameter Is 23 Mm. Technical Characteristics Of Mzva Srs-7-16 35747. Weight Kg 0.32., Hardware Press Clamp With One Hole In The Contact Leg And With Galvanic Coating Of The Contact Surface, Type A1a 70G-1, Insulator Caps St Rk Gost R 51204-2004 Type K-9 (Kp-24) Elastic And Stretch-Resistant Polyethylene Is Used As A Material For The Production Of Products, It Simultaneously Protects The Caps From Negative Natural Factors And Ensures A Long Service Life. They Function At Temperatures From -60 To +45 Degrees, Caps K 9 Are Resistant To Wear And Work For A Long Time, Not Requiring Service And Replacement, Fastening Of Insulators With The Help Of Caps Is Done Quickly And Simply Due To The Presence Of Threads On Their Surface. L, Mm ±1.0-71.0. Mass, Gr Not More Than 23.0, Ps-3-1 Type Connecting Plate Clamp For Steel Wires And Ropes When Grounding Lightning Protection Cables Of Overhead Power Lines 0.4 — 110 Kv. Clamps Are Produced In Accordance With The Requirements Of Tu 3449-029-84716711-2009 And Tu 3449-001-52819896-2010, Insulator Caps St Rk Gost R 51204-2004 Type K-6 (Kp-20) Made Of Polyethylene Resistant To Various Influences, Preventing Damage To Caps; Stable Operation At A Temperature Not Lower Than -60 And Not Higher Than +45 Degrees; The Presence Of A Thread For Convenient Fastening Of Insulators; Long-Term Working Resource; Wear Resistance L , Mm±1.0-42.0, Mass, Gr Not More Than 18.2, Terminal Coupling Heat-Shrinkable For A 1 Kv Cable 1Knt-4-120/240-Vl-M Intended For Terminating 4-Core Cables: With Plastic Insulation (Pvc/Spe) With Armor And Without Armor For A Voltage Of Up To 1 Kv. It Meets The Requirements Of Gost 13781.0-86. Types Of Mounted Cables: (А) Ввг, Nym, Nyy, (А) Пввг, (А) Вббшв, (А) Вбв, Аввб, (А) Ввбг, (А) Пвббшв, (А) Пвббшп. The Set For 4 Core Cables Is Universal And Can Be Used When Installing The Coupling, Both For Internal And External Installation. Hot-Melt Glue Applied To The Inner Surface Of The Glove And End Cuffs Ensures Complete Tightness Of The Coupling After Installation. A Non-Soldered Grounding System Is Used For Armored Cables. The Basic Set Includes A Roller Spring Of Constant Pressure, Used To Fasten The Grounding Wire To Armored Belts. When Installing The Grounding Unit On A Cable With Armor Made Of Steel Or Aluminum Wires, It Is Necessary To Additionally Use The Kmpb Grounding Kit Corresponding To The Selected Coupling. The Materials From Which The Heat-Shrinkable Components Of The Coupling Are Made Are Resistant To Ultraviolet Radiation And Weather Conditions. The Coupling Set Is Universal And Allows The Use Of Both Cable Ends For Crimping And Bolted Ends. Installation Tool: Propane Torch Pg (Kvt), Set For Breaking Off Heads Bolt Tips And Connectors Nmb-6 (Kvt). All Polymer Compositions Used For The Production Of Heat-Shrinkable Kvt Components Do Not Contain Halogens (Hf=Halogen Free)., Intermediate Link Of Type Prt-7-1 Three-Lobed Intermediate Link Three-Lobed Prt-7-1 Is Intended For Increasing The Length Of The Insulating Suspension, As Well As For The Transition From A Single-Lobed Eye To A Two-Lobed Eye. Structurally, The Prt-7-1 Consists Of Two Plates With A Bend. Because Of This, With A Symmetrical Arrangement, The Plate On One Side Of The Link Forms A Single-Lobed Eye, And On The Other Side, The Plates, Connected By A Finger With A Nut And A Cotter Pin, Form A Two-Lobed Eye. Intermediate Links Meet The Requirements Of Tu 3449-038-84716711-2009. Sizes, Mm: B1-17,B-16,D-16,D-17,A-70,L-110,H-36,B-61, Mass, Kg-0.462, Destructive Load R, Kn (I.E. P.), Not Less Than 70(7), Rolled Hot-Rolled Round Steel Made Of Ordinary Carbon And Low-Alloy Steel Gost 535-2005 With A Diameter Of 11-36 Mm, Rlnd-10/4 00U1 Disconnector With Prnz-10 Drive Rlnd 10/400 Three-Pole Disconnectors Are Intended For Universal Use In High-Voltage Networks And At Open Substations Of Alternating Current With A Frequency Of 50 Hz For Sectioning Of Networks And Disconnection From The Network Of Consumers Without Load Current, For The Formation Of A Visible Gap In Lines Nominal Voltage 6-10 Kv. Maximum Operating Voltage Kv 12. Nominal Current А 400. Current Of Thermal Resistance: For Grounding Blades For 1 S Ka 10. For Main Blades For 3 S Ka 10. The Largest Peak Of The Nominal Short-Time Withstand Current (Current Of Electrodynamic Resistance) Ka 25. Length Leakage Paths Of External Insulation, Not Less Than 30 Cm. Permissible Mechanical Load On The Outputs, Taking Into Account The Influence Of Wind And Ice, Not Less Than Н 200. Electrical Resistance Of The Main Circuit Ohm 175×10-6. The Greatest Effort Applied To The Drive When The Length Of The Operating Handle Together With The Extension Is No More Than 10 M N 245. Mass, No More Than Kg 38. Overall Dimensions Mm 1200×470×385., The Nkk-1-1B Tensioning Wedge Wedge Clamp The Nkk-1-1B Tensioning Wedge Wedge Clamp Is Designed For Fastening Aluminum, Steel-Aluminum And Protected Wires Sip-3, Pzv And Pzvg With A Cross-Section From 10 To 50 Mm2 And Steel Ropes With A Cross-Section From 25 To 50, 45 Mm2 To Tension Suspensions Of Anchor, Anchor-Corner And End Supports. It Is Necessary To Remove The Insulation From The Protected Wires In The Place Of The Clamp. The Strength Of The Wire Seal Is Produced According To Tu 3449-001-52819896-2010. Destructive Load, Kn, Not Less Than 60, Mass, Kg, Not More Than 0.85, Aluminum Cable Ends A 150-16-17 (100) Gost R 51177-98, Drive Shaft Ra 3, Galvanized, T.P.3.407.1-143 Gost 23118-2012, Pressed Hardware Clamp With Two Holes In The Contact Leg And With A Galvanic Coating Of The Contact Surface, Type A2a 35G-1. For Connecting One Aluminum Or Steel-Aluminum Wire To The Terminals Of The Devices. Clamps Meet The Requirements Of Tu 3449-022-84716711-2009., End Coupling For Cables With Paper Insulation, Internal Installation, Voltage 10 Kv, With Bolt Connectors, With Break-Off Heads Gost 13781.0-86 Type 10Kwtp-3-70/120-Sl-Nb, Sk-7-1A Type Clamp Sk-7-1A Clamps Are Most In Demand And Are Intended For The Execution Of Chain-Type Hinged Connections On Overhead Lines And Overhead Lines-Overhead Lines. They Make It Possible To Make A Transition From The Clamps Of One Ton Row (The First Number In The Marking Indicates The Tonnage Row Of The Coupling Armature) To The Clamps Of The Adjacent (For Example Sk-12-1A) Second Ton Row By Chain Connection. With The Help Of Staples, A Garland Of Insulators Is Attached To The Support Traverses. In Addition, Various Technical Devices Are Equipped With This Clamp: Mounting Ladders, Dynamometers, Etc. Sizes, Mm: B-66, B1-17, D-42, D-16,D1-14, H-50,H1-85, Mass, Kg-0.38, Destructive Load P, Kn (T.S. ), Not Less Than 70(7), Mesh Netting 30X30 Gost 5336-80, Pa-2-2 Type Connecting Flat Clamp Pa-2-2 Three-Bolt Flat Clamp For Joining Steel-Aluminum And Aluminum Wires During Installation Of Overhead Power Lines. It Is Also Used For The Arrangement Of Branches. It Is Used On Power Lines With A Voltage Of Up To 10 Kv. They Correspond To Tu 3449-001-52819896-2010. Pa-2-2 Die Three-Bolt Clamp Consists Of The Following Parts: Base Die With Three Holes For Bolts And Grooves For Wires; Three Pressing Plates; Three Bolts With Nuts And Washers. Wire Diameter, Mm-9.6-11.4, Sizes, Mm A-30, B-46, D-12, L-82, H-47, Weight, Kg-0.35, Ps-2-1 Type Connecting Plate Clamp For Steel Wires And Ropes When Grounding Lightning Protection Cables Of Overhead Power Lines 0.4 — 110 Kv. Clamps Meet The Requirements Of Tu 3449-029-84716711-2009 And Tu 3449-001-52819896-2010. Diameter Of Ropes According To Gost 3062-80; Gost 3063-80; Gost 3064-80 And Ps Grade Steel Wires, Mm-9.1-12.0, Sizes, Mm: A-34, A1-46,B-58,L-70,H-36,R-9, Weight, Kg-0.25, Stands For Fencing - Seamless Hot-Deformed Steel Pipes Of Grade 15, 20, D 76 Mm, Wall Thickness 4.5 Mm Gost 8731-74, Splicing Clamps Clamp U 859 (4-35, 50-70) Splicing Clamps Are Used To Create Copper And Aluminum Wires Branched From Main Lines With A Voltage Of Up To 660V With Preliminary Removal Of The Insulation At The Installation Site Without Cutting The Conductor., Rolled High-Grade Steel Hot-Rolled Carbon Steel Strip, 40 Mm Wide, 4 Mm Thick Gost 535-2005 (Gost 103-2006), Tension Bolt Type Nb-2-6A Clamp, Cable End Coupling For 3-Core Cables With Paper-Impregnated Insulation For A Voltage Of 10 Kv Hek-10Knt-3-70/120-Sl-M, Connecting Coupling For A Four-Wire Cable, With Armor With Aluminum Or Copper Wires With Polyethylene Insulation, Voltage 1 Kv, With Bolt Connectors, With Break-Off Heads Gost 13781.0-86 Type Eks-1Ст-4-16/50-Вл-М, End Couplings For A Three-Core Cable With Cross-Linked Polyethylene Insulation With Armor Or Without Armor, External Installation For A Voltage Of 10 Kv, With Bolted Ends, With Break-Off Heads Type Rek-10Hh2-3-35/70-А-M Gost 13781.0-86 Technical Execution Rek-1Knt-V-M And Rek-1Knt-Vl-M – End Heat-Shrinkable Couplings Are Used For Cables With Plastic Insulation For A Voltage Of Up To 1 Kv. The Set Of Couplings Includes: Universal Tips With A Break-Off Bolt Head Manufactured By Gph; Mastic Tapes; Heat-Shrinkable Tubes And Insulators; Thermoshrinkable Glove; A Kit For Grounding Armor Using A Non-Soldering System, Which Includes A Grounding Wire With A Tip And Spring Rings (Only For A Kit For An Armored Cable); Installation Instructions. The Design Of The Coupling Consists Of Heat-Shrinkable Parts. The Root Of The Cable Is Sealed With The Help Of A Heat-Shrinkable Glove, On The Inner Surface Of Which Hot-Melt Glue Is Applied. The Cores Of The Cable Are Protected By A Heat-Shrinkable Insulating Tube, The Length Of Which Is Determined During Installation, In The Range From 400 Mm To 800 Mm. The Space Between The Tip And The Insulation Of The Wire Is Sealed With The Help Of A Special Mastic And A Heat-Shrinkable Tube With An Adhesive Layer. In The Rek-1Knt-Vl-M Coupling, The Grounding Output Of The Cable Armor Is Made Without Soldering With The Help Of Spring Rings And A Grounding Conductor With A Tip. Application Of Rek-1Knt-V-M And Rek-1Knt-Vl-M Terminal Couplings Of External And Internal Installation Are Intended For Terminating Cables With Plastic Insulation For A Voltage Of Up To 1 Kv.
Key Value
Tender Value
6,232,192 - KZT
Tender Documents
Global Tender Document
dd041c7c-c454-4ef5-b872-3356544f05ca.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.