GTR 81687337

Request For Quotation Medical Analyzer Solution. Carefully Watch The Technical Specifications, Agree With The Customer, In Case Of Non-Conformity, The Product Must Be Returned, All Costs Are At The Expense Of The Supplier.

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
81687337
Tendering Authority
Subscribe to view
Tender No
12586119
Financer Name
Self-Funded
Work Title
Request For Quotation Medical Analyzer Solution. Carefully Watch The Technical Specifications, Agree With The Customer, In Case Of Non-Conformity, The Product Must Be Returned, All Costs Are At The Expense Of The Supplier.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
24-06-2024 Closed
Work Detail
942-066 Membranes For: Lactate Electrode. D7077 Lac Electrode Membrane Box - A Set Of 4 Membrane Electrode Covers Filled With An Electrolyte Solution. The Electrolyte Contains A Buffer, Inorganic Salts, Preservatives, Surfactants And A Binding Additive. For In Vitro Use Only. Membranes For: Lactate Electrode Membranes Are Accessories Necessary For The Operation Of The Laboratory Analyzer Of The Abl800 Flex Series, Which Is Used To Measure Blood Ph, Electrolytes And Metabolites, Hemoglobin And Its Fractions (Depending On The Configuration Of The Analyzer) And Diagnostics Of The Acid-Base State Of The Human Body, Electrolyte Balance , Metabolites And The Status Of Tissue Oxygenation And Gas Exchange. Directly Used In The Process Of Whole Blood Analysis. Principle Of Operation: The Membrane Is A Plastic Flask Filled With A Reagent Solution (Electrolyte) With A Selective Measuring Surface For Lactate Molecules. The Electrode Is Placed In A Membrane Filled With Electrolyte. The Membrane Electrode Is Installed In The Allocated Marked Cell Of The Electrode Chamber Of The Unit For Measuring Electrolytes/Metabolites (El/Met) (Marked In The Figure). During The Analysis, Blood Is Fed Into The Electrode Chamber. The Blood Interacts With The Measuring Surface Of The Membrane To Which Voltage Is Applied Through The Electrode. When A Voltage Is Applied Inside The Membrane, An Electrochemical Reaction Occurs In The Electrolyte Solution. During The Reaction, The Change In Current Strength Is Measured. The Change In Current Strength Correlates With The Value Of Lactate Concentration In The Blood. Must Be Compatible With Radiometer Abl800 Analyzer. The Method Of Registering The Replacement Of The Solution By Scanning A Bar Code, Which Is Recognized And Read By The Analyzer. Gost 1625-2016, 984-070 Thermal Paper For A Printer In A Roll. Spectrometric Thermographic Paper, 8 Rolls It Is Used In The Thermal Printer Of The Abl800 Flex Analyzer To Print Out The Results Of The Gost 1625-2016 Analysis, 944-129 Calibration Solution 2-200 Ml. Calibration Solution 2 S1830, 200 Ml., Abl800 Flex Usage: For Calibrating Ph, Electrolyte And Metabolite Electrodes. The Quantity Is 200 Ml. Composition: Substance K+ (Concentration: 40 Mmol/L), Na+ (Concentration: 20 Mmol/L), Ca2+ (Concentration: 5 Mmol/L), Cl- (Concentration: 50 Mmol/L), Cglu (Concentration: 10 Mmol/L), Clac (Concentration: 4 Mmol/L), Buffer (Concentration: Maintains A Ph Of 6.9) There Must Be A Bar Code On The Outside Of The Product That Can Be Read By The Abl800 Analyzer. The Solution Must Be Compatible With The Abl 800 Flex Kshs Analyzer. . Gost 1625-2016, 942-058Membranes For: Reference Electrode. Membranes Are Accessories Necessary For The Operation Of The Laboratory Analyzer Of The Abl800 Flex Series, Used For Measuring Blood Ph, Electrolytes And Metabolites, Hemoglobin And Its Fractions (Depending On The Configuration Of The Analyzer) And Diagnostics Of The Acid-Base State Of The Human Body, The Balance Of Electrolytes, Metabolites And Oxygenation Status Tissues And Gas Exchange. Directly Used In The Process Of Whole Blood Analysis. Only For In Vitro Diagnostics. Working Principle: The Membrane Is A Plastic Flask Filled With A Reagent Solution (Electrolyte). An Ion-Selective Membrane Is Located On The Lower End Of The Flask. The Electrode Is Placed In A Membrane Filled With A Reagent (Electrolyte). The Membrane Electrode Is Installed In The Measuring Chamber, In The Corresponding Cell. During The Analysis, Blood Is Fed Into The Measuring Chamber. The Blood Interacts With The Measuring Surface Of The Membrane To Which Voltage Is Applied Through The Electrode. When A Voltage Is Applied Inside The Membrane, The Conductivity Of The Reagent (Electrolyte) Changes. During The Reaction, The Final Voltage Is Measured. The Value Of This Voltage Is A Reference Value And Serves To Calculate The Parameters Measured By The Principle Of Potentiometry. It Must Be Compatible With The Abl800 Kshs Analyzer. The Method Of Registering The Replacement Of The Solution By Scanning A Bar Code, Which Is Recognized And Read By The Analyzer. Gost 1625-2016, 942-065 Membranes For: Glucose Electrode. D7066 Glu Electrode Membrane Box - A Set Of 4 Membrane Electrode Covers Filled With An Electrolyte Solution. The Electrolyte Contains A Buffer, Inorganic Salts, Preservatives, Surfactants And A Binding Additive. For In Vitro Use Only. Membranes For The Glucose Electrode Membranes Are Accessories Necessary For The Operation Of The Laboratory Analyzer Of The Abl800 Flex Series, Used For Measuring Blood Ph, Electrolytes And Metabolites, Hemoglobin And Its Fractions (Depending On The Configuration Of The Analyzer) And Diagnostics Of The Acid-Base State Of The Human Body, Electrolyte Balance, Metabolites And The Status Of Tissue Oxygenation And Gas Exchange. Directly Used In The Process Of Whole Blood Analysis. Only For In Vitro Diagnostics. Principle Of Operation: The Membrane Is A Plastic Flask Filled With A Reagent Solution (Electrolyte) With A Measuring Surface Selective For Glucose Molecules. The Electrode Is Placed In A Membrane Filled With A Reagent (Electrolyte). The Membrane Electrode Is Installed In The Allocated Marked Cell Of The Electrode Chamber Of The Unit For Measuring Electrolytes/Metabolites (El/Met) (Marked In The Figure). During The Analysis, Blood Is Fed Into The Electrode Chamber. The Blood Interacts With The Measuring Surface Of The Membrane, To Which Voltage Is Applied Through The Electrode. When A Voltage Is Applied Inside The Membrane, An Electrochemical Reaction Occurs In The Electrolyte Solution. During The Reaction, The Change In Current Strength Is Measured. The Change In Current Strength Correlates With The Value Of Glucose Concentration In The Blood. It Must Be Compatible With The Abl800 Kshcs Analyzer. The Method Of Registering The Replacement Of The Solution By Scanning A Bar Code, Which Is Recognized And Read By The Analyzer. Gost 1625-2016, 943-906 Hypochlorite-100 Ml. Hypochlorite-100 Ml. Composition: 3-5% Sodium Hypochlorite 95-97% Water Hypochlorite Of A High Degree Of Chemical Purification, Intended For Washing The System Of Tubes Of The Blood Acid-Alkaline And Gas Composition Analyzer For The Purpose Of Removing Proteins And Disinfection. Supplied In Plastic Bottles, Volume 100 Ml. The Solution Must Be Compatible With The Abl 800 Flex Kshcs Analyzer. Gost 1625-2016, 944-076 Autocheck Quality Control Solutions: Level 3, 30 Ampoules Per Package. Quality Control Solution, Level 3, Box Of 30 Ampoules, For The Abl800 Flex Analyzer. – A Quality Control System For Assessing The Accuracy And Precision Of The Parameters And Control Limits Given In The Insert Of Each Box. For Use By Authorized Personnel. One Ampoule Contains 0.7 Ml Of Control Solution. The Control Solution Is An Aqueous Solution That Contains A Biological Buffer, Salts And Preservatives, And Is Equilibrated With Oxygen And Carbon Dioxide. They Are Hermetically Sealed Ampoules Made Of Polymer Material, Containing Known Concentrations Of Electrolytes And Metabolites Inside. Data On The Concentration Of Analytes Are Encoded In An Insert With A Barcode. This Barcode Is Read By A Built-In Barcode Scanner, And Data On The Concentration Of Control Materials Of A Certain Lot Is Entered Into The Software Of The Analyzer. The Ampoules Are Inserted Into A Drum-Type Plastic Stand And Installed On The Analyzer Board. Control Measurements Are Performed On A Schedule By A Programmable Operator Or Forced Through The Analyzer Software. Puncture Of The Ampoule Cover And Sampling Of The Control Material Is Performed Completely Automatically By The Analyzer. To Exclude Errors Of The Human Factor, A Bar Code Is Applied To The Ampoules. The Color Of The Ampoule Caps Varies Depending On The Level Of Quality Control. The Quality Control Solution Is An Aqueous Solution Containing A Biological Buffer, Salts And A Stabilizer And Balanced With Carbon Dioxide And Oxygen. Some Solutions Also Contain Glucose, Lactate And Dyes. Must Be Compatible With The Abl800 Analyzer. The Method Of Registration Of Control By Scanning A Barcode, Which Is Recognized And Read By The Analyzer. Gost 1625-2016, 942-892 Sampler Module Needle. A Set For Taking Blood Samples With Heparinized Plastic Capillaries - Thin Plastic Tubes Used For Taking Blood From A Finger. Metal Wires - Mixers, Are Used To Mix The Blood In The Capillary, So That The Blood Does Not Clot. Caps Are Caps For Capillaries, Used To Prevent Blood From Leaking Out Of The Capillary. The Volume Is 85 Μl. Up. (250 Pcs.) Gost 1625-2016, 956-518Safe Pico70 Without Needle. Volume 1.5 Ml, Without A Needle; Type Of Heparin - Dry Li Heparin, Balanced By Electrolytes, Applied To Cellulose Fibers; Piston Material - Elastic Polymer With Cellulose Filter; Stub - Tipcap; Self-Filling Syringe; In A Package Of 100 Pcs.; Gost 1625-2016, 944-077 Autocheck Quality Control Solutions: Level 4, 30 Ampoules Per Package. Quality Control Solution, Level 4, Green Box Of 30 Ampoules, For The Abl800 Flex Analyzer - A Quality Control System For Assessing The Accuracy And Precision Of The Parameters And Control Limits Given In The Insert Of Each Box. For Use By Authorized Personnel. One Ampoule Contains 0.7 Ml Of Control Solution. The Control Solution Is An Aqueous Solution That Contains A Biological Buffer, Salts And Preservatives, And Is Equilibrated With Oxygen And Carbon Dioxide. They Are Hermetically Sealed Ampoules Made Of Polymer Material, Containing Known Concentrations Of Electrolytes And Metabolites Inside. Data On The Concentration Of Analytes Are Encoded In An Insert With A Barcode. This Barcode Is Read By A Built-In Barcode Scanner, And Data On The Concentration Of Control Materials Of A Certain Lot Is Entered Into The Software Of The Analyzer. The Ampoules Are Inserted Into A Drum-Type Plastic Stand And Installed On The Analyzer Board. Control Measurements Are Performed On A Schedule By A Programmable Operator Or Forced Through The Analyzer Software. Puncture Of The Ampoule Cover And Sampling Of The Control Material Is Performed Completely Automatically By The Analyzer. To Exclude Errors Of The Human Factor, A Bar Code Is Applied To The Ampoules. The Color Of The Ampoule Caps Varies Depending On The Level Of Quality Control. The Quality Control Solution Is An Aqueous Solution Containing A Biological Buffer, Salts And A Stabilizer And Balanced With Carbon Dioxide And Oxygen. Some Solutions Also Contain Glucose, Lactate And Dyes. Must Be Compatible With The Abl800 Analyzer. The Method Of Registration Of Control By Scanning A Barcode, Which Is Recognized And Read By The Analyzer. Gost 1625-2016, 942-059 Membranes For: K-Electrode. Membranes For The K Electrode Membranes Are Accessories Necessary For The Operation Of The Laboratory Analyzer Of The Abl800 Flex Series, Which Is Used To Measure The Ph Of Blood, Electrolytes And Metabolites, Hemoglobin And Its Fractions (Depending On The Configuration Of The Analyzer) And Diagnostics Of The Acid-Base State Of The Human Body, Electrolyte Balance, Metabolites And The Status Of Tissue Oxygenation And Gas Exchange. Directly Used In The Process Of Whole Blood Analysis. Only For In Vitro Diagnostics. Principle Of Operation: The Membrane Is A Plastic Flask Filled With A Reagent Solution (Electrolyte) With An Ion-Selective Potassium Ion Membrane Located On The Lower End Of The Flask. The Electrode Is Placed In A Membrane Filled With A Reagent (Electrolyte). The Membrane Electrode Is Installed In The Allocated Marked Cell Of The Electrode Chamber Of The Unit For Measuring Electrolytes/Metabolites (El/Met) (Marked In The Figure). During The Analysis, Blood Is Fed Into The Electrode Chamber. The Blood Interacts With The Measuring Surface Of The Membrane To Which Voltage Is Applied Through The Electrode. When A Voltage Is Applied Inside The Membrane, An Electrochemical Reaction Occurs In The Electrolyte Solution. During The Reaction, The Final Voltage Is Measured. The Value Of The Measured Parameter Is Equal To The Potential Difference On The Reference Electrode And The K Electrode. It Must Be Compatible With The Abl800 Kshs Analyzer. The Method Of Registering The Replacement Of The Membrane Using Barcode Scanning, Where The Analyzer Recognizes And Reads Gost 1625-2016, 942-062 Membranes For: Na-Electrode. Membranes For The Na Electrode Membranes Are Accessories Necessary For The Operation Of The Laboratory Analyzer Of The Abl800 Flex Series, Which Is Used To Measure The Ph Of Blood, Electrolytes And Metabolites, Hemoglobin And Its Fractions (Depending On The Configuration Of The Analyzer) And Diagnostics Of The Acid-Base State Of The Human Body, Electrolyte Balance, Metabolites And The Status Of Tissue Oxygenation And Gas Exchange. Directly Used In The Process Of Whole Blood Analysis. Only For In Vitro Diagnostics. Principle Of Operation: The Membrane Is A Plastic Flask Filled With A Reagent Solution (Electrolyte) With An Ion-Selective Sodium Ion Membrane Located On The Lower End Of The Flask. The Electrode Is Placed In A Membrane Filled With A Reagent (Electrolyte). The Membrane Electrode Is Installed In The Allocated Marked Cell Of The Electrode Chamber Of The Unit For Measuring Electrolytes/Metabolites (El/Met) (Marked In The Figure). During The Analysis, Blood Is Fed Into The Electrode Chamber. The Blood Interacts With The Measuring Surface Of The Membrane To Which Voltage Is Applied Through The Electrode. When A Voltage Is Applied Inside The Membrane, An Electrochemical Reaction Occurs In The Electrolyte Solution. During The Reaction, The Final Voltage Is Measured. The Value Of The Measured Parameter Is Equal To The Potential Difference On The Reference Electrode And The Na Electrode. It Must Be Compatible With The Abl800 Kshs Analyzer. The Method Of Registering The Replacement Of The Membrane With The Help Of Bar Code Scanning, Which Is Recognized And Read By The Analyzer Gost 1625-2016, 942-061 Membranes For: Cl-Electrode. Membrane Box Cl Electrode - A Set Of 4 Membrane Electrode Covers Filled With An Electrolyte Solution. The Electrolyte Contains Inorganic Salts, Organic Substances, Hygroscopic Substances And Preservatives. For In Vitro Use Only. Membranes For The Cl Electrode Membranes Are Accessories Necessary For The Operation Of The Laboratory Analyzer Of The Abl800 Flex Series, Which Is Used To Measure The Ph Of Blood, Electrolytes And Metabolites, Hemoglobin And Its Fractions (Depending On The Configuration Of The Analyzer) And Diagnostics Of The Acid-Base State Of The Human Body, Electrolyte Balance, Metabolites And The Status Of Tissue Oxygenation And Gas Exchange. Directly Used In The Process Of Whole Blood Analysis. Only For In Vitro Diagnostics. Principle Of Operation: The Membrane Is A Plastic Flask Filled With A Reagent Solution (Electrolyte) With An Ion-Selective Chlorine Ion Membrane Located On The Lower End Of The Flask. The Electrode Is Placed In A Membrane Filled With A Reagent (Electrolyte). The Membrane Electrode Is Installed In The Allocated Marked Cell Of The Electrode Chamber Of The Unit For Measuring Ph/Blood Gases (Ph/Bg) (Marked In The Figure). During The Analysis, Blood Is Fed Into The Electrode Chamber. The Blood Interacts With The Measuring Surface Of The Membrane To Which Voltage Is Applied Through The Electrode. When A Voltage Is Applied Inside The Membrane, An Electrochemical Reaction Occurs In The Electrolyte. During The Reaction, The Final Voltage Is Measured. The Value Of The Measured Parameter Is Equal To The Potential Difference On The Reference Electrode And The Cl Electrode. It Must Be Compatible With The Abl800 Kshs Analyzer. The Method Of Registering The Replacement Of The Membrane With The Help Of Bar Code Scanning, Which Is Recognized And Read By The Analyzer Gost 1625-2016, 944-074 Autocheck Quality Control Solutions: Level 1 Of 30 Ampoules Per Package. Quality Control Solution, Level 1, Box Of 30 Ampoules, For The Abl800 Flex Analyzer – A Quality Control System For Assessing The Accuracy And Precision Of The Parameters And Control Limits Given In The Insert Of Each Box. For Use By Authorized Personnel. One Ampoule Contains 0.7 Ml Of Control Solution. The Control Solution Is An Aqueous Solution That Contains A Biological Buffer, Salts And Preservatives, And Is Equilibrated With Oxygen And Carbon Dioxide. They Are Hermetically Sealed Ampoules Made Of Polymer Material, Containing Known Concentrations Of Electrolytes And Metabolites Inside. Data On The Concentration Of Analytes Are Encoded In An Insert With A Barcode. This Barcode Is Read By A Built-In Barcode Scanner, And Data On The Concentration Of Control Materials Of A Certain Lot Is Entered Into The Software Of The Analyzer. The Ampoules Are Inserted Into A Drum-Type Plastic Stand And Installed On The Analyzer Board. Control Measurements Are Performed On A Schedule By A Programmable Operator Or Forced Through The Analyzer Software. Puncture Of The Ampoule Cover And Sampling Of The Control Material Is Performed Completely Automatically By The Analyzer. To Exclude Errors Of The Human Factor, A Bar Code Is Applied To The Ampoules. The Color Of The Ampoule Caps Varies Depending On The Level Of Quality Control. The Quality Control Solution Is An Aqueous Solution Containing A Biological Buffer, Salts And A Stabilizer And Balanced With Carbon Dioxide And Oxygen. Some Solutions Also Contain Glucose, Lactate And Dyes. Must Be Compatible With Abl800 Analyzer. The Method Of Registration Of Control By Scanning A Barcode, Which Is Recognized And Read By The Analyzer. Gost 1625-2016, 944-075 Autocheck Quality Control Solutions: Level 2, 30 Ampoules Per Pack. Quality Control Solution, Level 2, Box Of 30 Ampoules, For The Abl800 Flex Analyzer. They Are Hermetically Sealed Ampoules Made Of Polymer Material, Containing Known Concentrations Of Electrolytes And Metabolites Inside. Data On The Concentration Of Analytes Are Encoded In An Insert With A Barcode. This Barcode Is Read By A Built-In Barcode Scanner, And Data On The Concentration Of Control Materials Of A Certain Lot Is Entered Into The Software Of The Analyzer. Ampoules Are Inserted Into A Drum-Type Plastic Stand And Installed On The Analyzer Board. Control Measurements Are Performed On A Schedule By A Programmable Operator Or Forced Through The Analyzer Software. Puncture Of The Ampoule Cover And Sampling Of The Control Material Is Performed Completely Automatically By The Analyzer. To Exclude Errors Of The Human Factor, A Bar Code Is Applied To The Ampoules. The Color Of The Ampoule Caps Varies Depending On The Level Of Quality Control. A Quality Control Solution Is An Aqueous Solution Containing A Biological Buffer, Salts, And A Stabilizer And Balanced With Carbon Dioxide And Oxygen. Some Solutions Also Contain Glucose, Lactate And Dyes. Must Be Compatible With The Abl800 Analyzer. The Method Of Registration Of Control By Scanning A Barcode, Which Is Recognized And Read By The Analyzer. Gost 1625-2016, 942-064 Membranes For: Po2-Electrode. Membranes Are Accessories Necessary For The Operation Of The Laboratory Analyzer Of The Abl800 Flex Series, Used For Measuring Blood Ph, Electrolytes And Metabolites, Hemoglobin And Its Fractions (Depending On The Configuration Of The Analyzer) And Diagnostics Of The Acid-Base State Of The Human Body, The Balance Of Electrolytes, Metabolites And Oxygenation Status Tissues And Gas Exchange. Directly Used In The Process Of Whole Blood Analysis. Only For In Vitro Diagnostics. Working Principle: The Membrane Is A Plastic Flask Filled With An Electrolyte Solution With A Gas-Selective Measuring Surface For Oxygen Molecules. The Electrode Is Placed In A Membrane Filled With A Reagent (Electrolyte). The Membrane Electrode Is Installed In The Allocated Marked Cell Of The Electrode Chamber Of The Unit For Measuring Ph/Blood Gases (Ph/Bg) (Marked In The Figure). During The Analysis, Blood Is Fed Into The Electrode Chamber. The Blood Interacts With The Measuring Surface Of The Membrane, To Which Voltage Is Applied Through The Electrode. When A Voltage Is Applied Inside The Membrane, An Electrochemical Reaction Occurs In The Electrolyte. During The Reaction, The Current Is Measured. The Value Of The Change In Current Correlates With The Level Of Pressure Of Dissolved Oxygen In The Blood. It Must Be Compatible With The Abl800 Kshcs Analyzer. The Method Of Registering The Replacement Of The Solution By Scanning A Bar Code, Which Is Recognized And Read By The Analyzer. Gost 1625-2016, 905-671 Annual Service Kit For Abl800 Flex. The Service Kit For Abl800 Is Used For Annual Service Maintenance. The Annual Service Package Consists Of: Pump Sealing Rings - 5 Pcs. Sealing Rings Of Liquid Sensors - 7 Pcs. Liquid Rubber Tube - 2 Meters. Liquid Silicone Tube - 2 Meters. Rubber Probe Tube - 1 Pc. Rubber Heater Tube-1 Pc. Rubber Tube Of Measuring Modules - 3 Pcs. Rubber Tube Connectors (Angled) - 4 Pcs. Rubber Tube Of The Ph Module-1 Pc. Plug-1 Pc. Peristaltic Waste Tube-4 Pcs. Peristaltic Solution Tube - 2 Pcs. Peristaltic Tube Of Electrode Modules-4 Pcs. Rubber Tube Of The Oxi-Module Heater - 1 Pc. Tube Connector Valve Oxi-Module-1Pc. Liquid Section Fitting-1 Pc. Gasket Of The Entrance Hole - 2 Pcs. Air Filter-1 Pc. Y-Connector Fitting-1 Pc. Cleaning Sticks - 10 Pcs. Cleaning Napkin - 3 Pcs. Air Valve Membrane - 1 Pc. Connector Tube Gasket Inlet-1 Pc. Liquid Valve Membrane-1 Pc. Must Be Compatible With Abl800 Analyzer. The Method Of Registering Each Item By Scanning A Barcode, Which Is Recognized And Read By The Analyzer. Gost 1625-2016, 944-128-Calibration Solution 1-200 Ml. Calibration Solution 1 S1820, 200 Ml., Abl800 Flex, Use: For Calibration Of Ph, Electrolyte And Metabolite Electrodes. Quantity 200 Ml. Composition: Substance K+ (Concentration: 4 Mmol/L), Na+ (Concentration: 145 Mmol/L), Ca2+ (Concentration: 1.25 Mmol/L), Cl- (Concentration: 102 Mmol/L), Cglu (Concentration: 10 Mmol/L) , Clac (Concentration: 4 Mmol/L), Buffer (Concentration: Maintains A Ph Of 7.40) There Must Be A Bar Code On The Outside Of The Product That Can Be Read By The Abl800 Analyzer. The Solution Must Be Compatible With The Abl 800 Flex Kshs Analyzer. . Gost 1625-2016, 942-062 Membranes For: Na-Electrode. Membranes For The Na Electrode Membranes Are Accessories Necessary For The Operation Of The Laboratory Analyzer Of The Abl800 Flex Series, Which Is Used To Measure The Ph Of Blood, Electrolytes And Metabolites, Hemoglobin And Its Fractions (Depending On The Configuration Of The Analyzer) And Diagnostics Of The Acid-Base State Of The Human Body, Electrolyte Balance, Metabolites And The Status Of Tissue Oxygenation And Gas Exchange. Directly Used In The Process Of Whole Blood Analysis. Only For In Vitro Diagnostics. Principle Of Operation: The Membrane Is A Plastic Flask Filled With A Reagent Solution (Electrolyte) With An Ion-Selective Sodium Ion Membrane Located On The Lower End Of The Flask. The Electrode Is Placed In A Membrane Filled With A Reagent (Electrolyte). The Membrane Electrode Is Installed In The Allocated Marked Cell Of The Electrode Chamber Of The Unit For Measuring Electrolytes/Metabolites (El/Met) (Marked In The Figure). During The Analysis, Blood Is Fed Into The Electrode Chamber. The Blood Interacts With The Measuring Surface Of The Membrane To Which Voltage Is Applied Through The Electrode. When A Voltage Is Applied Inside The Membrane, An Electrochemical Reaction Occurs In The Electrolyte Solution. During The Reaction, The Final Voltage Is Measured. The Value Of The Measured Parameter Is Equal To The Potential Difference On The Reference Electrode And The Na Electrode. It Must Be Compatible With The Abl800 Kshs Analyzer. The Method Of Registering The Replacement Of The Membrane With The Help Of Bar Code Scanning, Which Is Recognized And Read By The Analyzer Gost 1625-2016, 906-020 Clot Trap For Capillaries, Pack (250 Pcs.) Collector For Blood Clots - A Disposable Clot Catcher Intended For Use On Capillaries To Prevent Clots Or Tissues From Entering The Abl800 Flex Analyzers. It Is Made Of Thermoplastic, The Tip Of The Trap Is Luer, Diameter 4 Mm, Cone 1.72O, Capillary Diameter - 1.4-2.0 Mm. Gost 1625-2016, 944-021 Calibration Solutions: Thb In A Pack. 4 Amp. S7770 Cthb Calibration Solution Composition: 96.5% Water 0.5-3% 4- (2-Hydroxyethyl) Piperazine-1 - Ethanesulfonic Acid 0.5-3% Sodium 4- (2-Hydroxyethyl) Piperazine-1 - Methanesulfonate. The Solution Must Be Compatible With The Abl 800 Flex Kshcs Analyzer. Gost 1625-2016, 942-060 Membranes For: Ca - Electrode. Membranes For The Ca Electrode Membranes Are Accessories Necessary For The Operation Of The Laboratory Analyzer Of The Abl800 Flex Series, Used For Measuring Blood Ph, Electrolytes And Metabolites, Hemoglobin And Its Fractions (Depending On The Configuration Of The Analyzer) And Diagnostics Of The Acid-Alkaline State Of The Human Body, Electrolyte Balance, Metabolites And The Status Of Tissue Oxygenation And Gas Exchange. Directly Used In The Process Of Whole Blood Analysis. Only For In Vitro Diagnostics. Principle Of Operation: The Membrane Is A Plastic Flask Filled With A Reagent Solution (Electrolyte) With An Ion-Selective Calcium Ion Membrane Located On The Lower End Of The Flask. The Electrode Is Placed In A Membrane Filled With Electrolyte. The Membrane Electrode Is Installed In The Allocated Marked Cell Of The Electrode Chamber Of The Unit For Measuring Electrolytes/Metabolites (El/Met) (Marked In The Figure). During The Analysis, Blood Is Fed Into The Electrode Chamber. The Blood Interacts With The Measuring Surface Of The Membrane To Which Voltage Is Applied Through The Electrode. When A Voltage Is Applied Inside The Membrane, An Electrochemical Reaction Occurs In The Electrolyte Solution. During The Reaction, The Final Voltage Is Measured. The Value Of The Measured Parameter Is Equal To The Potential Difference On The Reference Electrode And The Ca Electrode. It Must Be Compatible With The Abl800 Kshs Analyzer. The Method Of Registering The Replacement Of The Membrane Using Barcode Scanning, Where The Analyzer Recognizes And Reads Gost 1625-2016
Key Value
Tender Value
18,384,891 - KZT
Tender Documents
Global Tender Document
9d8d8d27-0d59-45c0-a6b2-c7b1f1c0ee2f.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders