GTR 81615968
Request For Quotation Purchase Of Spare Parts
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
81615968
Tendering Authority
Subscribe to view
Tender No
12580878
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Spare Parts
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
21-06-2024
Closed
Work Detail
Corner Faucet Corner Faucet, Thick-Walled, Full-Passage, Detachable, American, Diameter Not Less Than 25 Mm, Outdoor Unit For Air Conditioner Mideatechnical Characteristics Of The Outdoor Unit, Dimensions Of The Outdoor Unit (Hxwxd) 1167X900x340 Mm, Weight Of The Outdoor Unit 96 Kg, Refrigerant Type R410a, Temperature Modes Of Operation Of The Outdoor Unit, Minimum Outdoor Temperature For Cooling Mode -15 Co, Range Of Working Temperatures For Cooling -15 ... 43 Co, Minimum Outdoor Temperature For Heating Mode -7 Co, Operating Temperature Range For Heating -7 ... 24 Co, Connection Parameters Of The Outdoor Unit To The Indoor Unit, The Maximum Length Of The Route Between The Units Is 50 Meters, Difference The Height Between The Inner And Outer Blocks Is 25 Meters, The Diameter Of The Gas Tube Is 3/4 Inch, The Diameter Of The Liquid Tube Is 3/8 Inch,, The Cooling Section, Including The Mixing Unit And Pipe Fitting, Approx. C1(Pm1-2) Xpnd 04/7R., The Cooling Section, Including The Mixing Unit And Pipe Fitting, Approx. D2(P1)Xpnd 17/6R., The Cooling Section, Including The Mixing Unit And Pipe Fitting, Approx. C2(P7) Fpvd 2.7/6Rl., The Cooling Section, Including The Mixing Unit And Pipe Fitting Xpnd 06/7R., Gasket Gkt03852, Gasketrng0201e, Gasketrng01697, Heating Cable Not Less Than 17 W/M, Self-Regulating, Shielded., Three-Way Faucet Manometer Faucet. External - Internal Thread. Pn 16. Maximum Working Temperature 110°C., Bearings For Ventilators. Bearing In A Metal Bracket, Piston Compressor Receiver 24 L Number Of Cylinders - 2 Number Of Stages -1 Productivity 240 L/Min Pressure 10 Atm Power 1.5 Kw Voltage 220V Nominal Frequency 50 Hz Weight 29 Kg, Spiral Compressorspiral Compressor Typehermetic Construction Typehbp Compressor Operation Moderefrigerant R407cvolume Capacity, M3/Hour 19.2Power Supply: Voltage, Phases, Frequency _380-420/3/50Diameter Of Suction Pipe, Inch 7/8Diameter Of Discharge Pipe, Inch 3/4Compressor Connection For Soldering, There Are No Valves In The Set Oil Volume, L 1.7 Oil Type Rl32-3Maf Height, Mm 462 Width, Mm 242 Depth, Mm 242, Spiral Compressorspiral Compressor, For High/Medium Boiling Temperatures, Compressor Power 1.8 Hp, Volumetric Capacity - 5.3 M3/H, Noise Level 54Db, Oil Filling 1 L. Connection Diameters Of Pipelines: -Suction Pod Solder 3/4 Inch; Dimensions (Length, Width, Height) 26/22 Kg., Spiral Compressorspiral Type Compressor Purpose Of The Compressor High-Temperature (Conditioning) Refrigeration Coefficient (En 12900) 3.27 Capacity Regulation No Compressor Power Supply 3 Phases/380 V/50 Hz Range Of Cooling Capacity (En 12900), Kw 10-15 Cooling Capacity (En 12900), Kw 14.4 Height , Mm 438 Length, Mm 241 Width, Mm 247 Net Weight, Kg 43 Amount Of Oil, L 1.66 Noise Level, Dba 60 Intake Pipe, Inch 7/8 Discharge Pipe, Inch 1/2, Uninsulated Air Duct (Corrugated) The Type Of Air Duct According To The Shape Of The Section Is Round. The Material Type Of Air Duct Is Non-Metallic. Flexible Duct. Diameter 100 Mm., Uninsulated Air Duct (Corrugated) The Type Of Air Duct According To The Shape Of The Section Is Round. The Material Type Of Air Duct Is Non-Metallic. Flexible Duct. Diameter 200 Mm., Uninsulated Air Duct (Corrugated) The Type Of Air Duct According To The Shape Of The Section Is Round. The Material Type Of Air Duct Is Non-Metallic. Nasty Air Duct. Diameter 120 Mm., Uninsulated Air Duct (Corrugated) The Type Of Air Duct According To The Shape Of The Section Is Round. The Material Type Of Air Duct Is Non-Metallic. Flexible Duct. Diameter 160 Mm., Uninsulated Air Duct (Corrugated) The Type Of Air Duct According To The Shape Of The Section Is Round. The Material Type Of Air Duct Is Non-Metallic. Flexible Duct. Diameter 250 Mm., Compensator For Pipelines Of The Heating System Compensator Siphon Axial Du400 For Welding Length 1500 Mm. The Nominal Pressure Is 25 Bar. The Number Of Bellows Layers Is Two Or More. The Temperature Ranges From -200 To 550 Oc., Built-In Thermoregulator Valve Technical Characteristics: Kvs: 0.90 Kv Value At Xp=0.5-2.0 K: 0.04 — 0.7 Max. Working Pressure: 10 Bar, Max. Pressure Drop: 0.6 Bar, Test Pressure: 16 Bar Max. Water Temperature: 120 Ос, Thermostatic Valve Ra-N Built-In Diameter M30x1.5. Gost 30815-2002., Manometer Accuracy Class 1.5; Measurement Range 0...10 Bar; Case Diameter 100 Mm; Thread Of The Connecting Piece M20x1.5; The Location Of The Fitting Is Radial. Body - Steel Painted Black. Fitting And Tribko-Sector Mechanism: Brass. Interval: 1 Hour., Frequency Converter 7.5 Kw Power - 7.5 Kw Nominal Output Current - 16 A Voltage - 3X380-480 Brake Breaker - Included Emc Filter - H3 Class A1/B (C) Built-In Fieldbus - Rs-485 (Fc - Protocol, Modbus Rtu) Type Cooling - Forced Air Degree Of Protection - Ip20 Size - 90X239x194, Frequency Converter 5.5 Kw Power - 5.5 Kw Nominal Output Current - 12 A Voltage - 3X380-480 Brake Breaker - Included Emc Filter - H3 Class A1/B (C) Built-In Fieldbus - Rs-485 (Fc - Protocol, Modbus Rtu) Type Cooling - Forced Air Degree Of Protection - Ip20 Size - 90X239x194, Pump Seal, Face Seal. End Seal, Fan Speed Controlleradjustment Range [Bar]16-39 Bar, Adjustment Range [Psig]232-566 Psig, Ambient Temperature [°C] -20 - +55 °C, Outdoor Temperature Range [°C]-20 - 55 °C, Capillary Tube Length 900 ± 100 Mm, Connection Size 6.35 Mm Current 8 A, Degree Of Protection Ip54, Factory Setting [Bar] 32.00 Bar, Frequency [Hz] 50/60 Hz, Maximum Working Pressure [Bar] 47 ,0 Bar,Minimum Speed At 50 Hz 45%,, Compressorhlg083, Compressor 122/Ce-X 181, Compressor 31/Ce 51
Key Value
Tender Value
27,060,334 - KZT
Tender Documents
Global Tender Document
d2f6add5-51af-4d6c-a25e-b11ace810796.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.