GTR 81538354
Bids Are Invited For Contracting For The Provision Of Evaluation Services Of Physical And Chemical Occupational Hygiene Agents, For The Preparation Of Occupational Health And Safety Programs In The Municipality Of Goianésia, In Meet The Needs Of The Municipal Secretariat Of The Civil House. Bre The Memo No The Judgment Criteria Will Be Considered If Per Item Or Overall, We Verify And Rectify The Publication, Extending The Deadline For Another 3 Days. It Has Become Public That The Municipal City Of GoianésiaGo Will Make An Exemption, With (Judgement Criteria Lower Price Per Item), In The Hypothesis Of Art. 75, Item Ii, In Terms Of Law No. 14,133, Of April 1, 2021, Municipal Decree No. 2290 Of February 28, 2023, And Other Legislation Applicable To The Case.
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
81538354
Tendering Authority
Subscribe to view
Tender No
47580/2024
Financer Name
Self-Funded
Work Title
Bids Are Invited For Contracting For The Provision Of Evaluation Services Of Physical And Chemical Occupational Hygiene Agents, For The Preparation Of Occupational Health And Safety Programs In The Municipality Of Goianésia, In Meet The Needs Of The Municipal Secretariat Of The Civil House. Bre The Memo No The Judgment Criteria Will Be Considered If Per Item Or Overall, We Verify And Rectify The Publication, Extending The Deadline For Another 3 Days. It Has Become Public That The Municipal City Of GoianésiaGo Will Make An Exemption, With (Judgement Criteria Lower Price Per Item), In The Hypothesis Of Art. 75, Item Ii, In Terms Of Law No. 14,133, Of April 1, 2021, Municipal Decree No. 2290 Of February 28, 2023, And Other Legislation Applicable To The Case.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
18-06-2024
Closed
Work Detail
Noise Dosimetry For The Assessment Of Continuous Or Intermittent Noise - Requirements: The Assessment Must Be A Full Day (Minimum Of 80%), With A Break During The Break For Meals And Rest, And A Field Sheet Must Be Presented With The Relevant Information And Duly Signed By Paradigma And By The Executor And Photographic Report. Equipment: Dosimeter: Must Be At Least Type 2, According To The Specifications Of Ansi S1.25 And Iec 60804;, Iec61672 Class 1, Iec 60651 Class 1, Iec 61252 And Iec 61260; Configurations According To Nr 15 And Nho 01; Calibrator: Must Meet The Specifications Of The Iec60942:2003 Standard, And Be Of The Same Brand As The Dosimeter. The Report, In Addition To The Results, Must Contain Results In 1/3 Octave Bands, Graph, Histogram, Minute-By-Minute Report, Evidence Of Pre And Post Calibration, And Calculation Of The Attenuation Of The Protection Used (If Any). The Equipment To Be Used Must Present A Certificate Of Calibration Accredited / Tracked By Inmetro For Less Than 1 Year (Dosimeter And Calibrator), Which Must Be Presented In Advance For Approval. Should A Technical Responsibility Note Be Presented? Art Of Executing Assessments., Whole Body Vibration (Vci) - The Assessment Must Include, At A Minimum, A Complete Cycle Of The Activity, Regardless Of Its Duration, And A Field Sheet Must Be Presented With The Relevant Information And Duly Signed By Paradigma E By The Executor And Photographic Report. Equipment: The Meters To Be Used In The Assessment Must Be Integrative And Meet The Requirements Of The Iso 8041 Standard; Iso 2631; Iso 5349; European Directive 44T/2002. The Equipment To Be Used Must Present A Certificate Of Calibration Accredited / Tracked By Inmetro For Less Than 1 Year (Dosimeter And Calibrator), Vibration Of Hands And Arms (Vmb) - Assessment Must Include, Field Sheet Must Be Presented With The Relevant Information And Duly Signed By Paradigma And By The Executor And Photographic Report. Equipment: The Meters To Be Used In The Assessment Must Be Integrative, Meet The Requirements Of Iso 8041; Iso 2631; Iso 5349;European Directive 44T/2002. The Equipment To Be Used Must Present An Accredited Calibration Certificate / Tracked By Inmetro For Less Than 1 Year (Dosimeter And Calibrator), Which Must Be Presented In Advance For Approval. Should A Technical Responsibility Note Be Presented? Art Of Carrying Out The Assessments., Respirable Dust + Crystalline Free Silica - The Assessment Must Be A Full Day (Minimum Of 80%), And A Field Sheet Must Be Presented With The Relevant Information (Flow Rate, Collection Time, Temperature, Rh, Description Of The Activities, Etc.) And Duly Signed By Paradigm And By The Executor And Photographic Report. If Necessary, Provision Should Be Made For The Use Of More Than One Sampler To Cover The Entire Day. Equipment: Sampling Pump That Meets The Needs Of The Methodology Defined By The Laboratory; Cyclone Particle Separator (Nylon Or Aluminum); Pump Calibrator For Flow Defined By The Laboratory. The Equipment To Be Used Must Present A Certificate Of Calibration Accredited / Tracked By Inmetro For Less Than 1 Year (Pump And Calibrator). Assessment Procedures: For Assessment, Nho 08 Guidelines Must Be Followed. Pre- And Post-Collection Calibrations Must Be Carried Out In Accordance With The Procedure Described By Nho
Key Value
Tender Value
67,423 - BRL
Tender Documents
Global Tender Document
1c2afcf0-9b5f-434f-9141-f3ec068ae9a6.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.