GTR 81238257

Tenders Are Invited For Repair Service Of Fixed Fire-Extinguishing And Gas Devices Equipped In The Building Of The Silesian Provincial Office In Katowice At Ul. Jagiellońska 25

ICB — International Competitive Bid Closed central europe
Tender Information
GTR Reference
81238257
Tendering Authority
Subscribe to view
Tender No
BA.I.272.29.2024
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Repair Service Of Fixed Fire-Extinguishing And Gas Devices Equipped In The Building Of The Silesian Provincial Office In Katowice At Ul. Jagiellońska 25
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
central europe
Political Region
European Union
Last Date of Bid Submission
17-06-2024 Closed
Work Detail
The Subject Of The Order Is The Repair Service Of Fixed Fire Extinguishing And Gas Equipment In The Building Of The Silesian Provincial Office In Katowice At Ul. Jagiellońska 25, In Scope: 1) Extinguishing System In The Main Server Room: A) Polon Ignis 1520M Extinguishing Control Panel, B) Fire Extinguishing System: Fm-200 New Firec) Extinguishing Agent: Hfc227ea - 56 Kgd) Installation Of A Relief Flap Controlled From The Central Unit - Equipped With An Electric Actuator.E) Controlling The Flap To Seal The Room During Firefighting,F) Moving The Sa-K7 Signaling Device To A Visible Place In The Protected Room,G) Changing The Location Of The Start, Stop Buttons,H) Replacing The Detectors Smoke Under The Technical Floor,I) Sealing The Room,J) Improving The Outlet Of The Pipe To The Cable Duct - Perform According To The Design,K) Udt Legalization Of The Extinguishing Gas Tank.L) Measuring The Tightness Of The Room Using The Door Fan Test Method.2) Extinguishing System In The Wcpr Server Room :A) Polon Ignis 1520M Extinguishing Control Panel,B) Fire Extinguishing System: Mx 1230 3Mc) Extinguishing Agent: Fk-5-1-12 - 46.5 Kgd) Replacement Of The Relief Flap With A Control Panel-Controlled One Equipped With An Electric Actuator,E) Installation Relief Flap At A Height Of At Least 80% Of The Room Height. F) Installation Of The Sa-K7 Acoustic Alarm - In Accordance With The Design. G) Reconnecting The Warning Ceiling Lamp To The Control Panel Output Dedicated To The Warning Signal. H) Rewiring The Detection Lines So That There Are Detectors From Both Lines.I) Installation Of Activation Indicators For Detectors Located Under The Floor.J) Replacement Of Yntksyekw Wiring With Htkshekw (For Elements Requiring Fireproof Wiring). K) Udt Legalization Of The Extinguishing Gas Tank.L) Measurement Of Tightness Of The Room Using The Door Fan Test Method.3) Ups Wcpr Extinguishing System In The Room:A) Polon Ignis 1520M Extinguishing Control Panel,B) Fire Extinguishing System: Mx 1230 3Mc) Extinguishing Agent: Fk -5-1-12 - 46.5 Kgd) Installation (According To The Design) Of The Sa-K7 Acoustic Siren, E) Reconnecting The Warning Ceiling Lamp To The Control Panel Output Dedicated To The Warning Siren. F) Rewiring The Detection Lines So That There Are Detectors From Both Lines,G) Installation Of Indicators For Detectors Located Under The Floor.H) Sealing The Room.I) Replacement Of The Cover Of The Start Extinguishment Button.J) Replacement Of Yntksyekw Wiring With Htkshekw (For Elements Requiring Fire-Resistant Wiring). K) Udt Legalization Of The Extinguishing Gas Tank.L) Measurement Of The Tightness Of The Room Using The Door Fan Test Method.4) Extinguishing System In The Unit Room: A) Polon Ignis 1520M Extinguishing Control Panel, B) Fire Extinguishing System: Mx 1230 3Mc) Extinguishing Agent: Fk- 5-1-12 - 46.5 Kgd) Replacement Of The Relief Flap With One Controlled From The Control Panel And Equipped With An Electric Actuator, E) Installation Of The Sa-K7 Acoustic Alarm - In Accordance With The Design. F) Overvoltage Of The Warning Ceiling Lamp For The Control Panel Output Dedicated To The Warning Signal.G ) Replacement Of The Start And Stop Extinguishing Buttons. H) Replacement Of Yntksyekw Wiring With Htkshekw (For Elements Requiring Fire-Resistant Wiring). I) Udt Legalization Of The Extinguishing Gas Tank. J) Measurement Of Room Tightness Using The Door Fan Test Method.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
d1f2e0ad-65ab-4d17-bcd9-1eaa9ce14860.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders