GTR 81140836

Tenders Are Invited For Reconstruction Of The Rooms Of The Old Operating Theater In The District Hospital In Stalowa Wola

ICB — International Competitive Bid Closed central europe
Tender Information
GTR Reference
81140836
Tendering Authority
Subscribe to view
Tender No
IMP.272.2.9.2024
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Reconstruction Of The Rooms Of The Old Operating Theater In The District Hospital In Stalowa Wola
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
central europe
Political Region
European Union
Last Date of Bid Submission
26-06-2024 Closed
Work Detail
1. The Subject Of The Order Is The Reconstruction Of The First Floor Of The Building Of The First Pavilion Of The District Specialist Hospital In Stalowa Wola, Ul. Staszica 4, 37-450 Stalowa Wola For The Needs Of The General Surgical Department With The Sub-Division Of Vascular Surgery And The Sub-Division Of Neurosurgery Along With Equipment, In Accordance With The Price Form, Construction Design And Technical And Executive Design, Description Of The Subject Of The Order, List Of Equipment And Requirements Specified In The Swz. Note: Construction Works That Are The Subject Of The Order Will Be Carried Out In An Active Hospital Facility. 2. General Information: The Scope Includes All Works Related To The Reconstruction Of Part Of The First Floor Of The Building, Along With The Renovation And Adaptation Of Staircases K1 And K2 In The Field Of Smoke Exhaust, As Well As The Replacement Of Windows And Doors.2.1. General Construction Works: - Demolition Works, - Partition Walls And Installation Shaft Casings Made Of Plasterboards With Double Boarding, Painted, Covered With Tiles Or Cladding, - Installation Of Structural Elements (Lintels, Ring Beams, Substructures For Ventilation Devices, As Well As Roof Structure Elements Related To With Installation Of Smoke Exhaust Flaps), - Floor Layers With Thermal And Waterproof Insulation, With Floor Finishing (Pvc Floor Covering, Stoneware Tiles), - Gypsum Plaster On Existing And Planned Masonry Walls - Suspended Ceilings, - Aluminum Joinery/Door And Window Joinery, - Installation Of Wooden, Aluminum And Steel Doors, - Installation And Connection Of Smoke Exhaust Flaps For K1 And K2 Staircases, - Installation Of Non-Flammable Strips, - Repair And Sealing Of The Roof In Places Of Existing Water Stains, - Repair Of External Plasters And Painting Parts Of The Facade In Places Where Non-Flammable Strips Are Used, - Delivery And Installation Of Equipment And Technology Elements (Including Medical Columns, Bedside Panels), - Replacement Of Internal And External Window Sills, - Repair Of Plasters And Their Repainting Resulting From The Installation Of Windows And External Doors, - Securing Ceilings To The Required Fire Insulation Parameters, - Repair Of Roof Covering And Thermal, Waterproof And Moisture-Proof Insulation Resulting From Installation Of Smoke Exhaust Flaps.2.2. Sanitary Installations 2.2.1. Water And Sewage: Works Should Be Carried Out Regarding All Activities Enabling And Aimed At Performing The Following Installations: - Dismantling Existing Water And Sewage Installations, - Installation Of Cold And Hot Water And Circulation, - Hydrant Installation, - Sanitary Sewage Installation ,- Installation Of Condensate, - Connection Of Sanitary Utensils Located In The Rebuilt Rooms To The Existing Water Supply Lines Located On The Rebuilt Floor, - Approaches To The Utensils Made Of Low-Noise Pvc Pipes, - Connection Of Sanitary Utensils Located In The Rebuilt Rooms To The Existing Sewerage Lines Located On The Rebuilt Floor, - White Accessories: Wall Taps, Porcelain Washbasins And Toilet Bowls, Stainless Steel Sinks, Shower Trays, Etc.2.2.2. Central Heating Installation. Work Should Be Carried Out Regarding All Activities Enabling And Aimed At Implementing Internal Heating Installations. - Dismantling The Existing Central Heating Installation, - Central Heating Installation, - Installation Of Technological Heat And Glycol Recovery, - Hygienic Radiators, Mounted To The Walls Using A Stable System. 2.2.3. Mechanical Ventilation Works Should Be Carried Out Regarding All Activities Enabling And Aimed At Implementing An Internal Mechanical Ventilation Installation With Automation. - Dismantling The Existing Mechanical Ventilation Installation, - Ventilation Of Toilet Rooms Should Be Performed Mechanically Using Exhaust Ventilation Systems Powered By Bathroom Fans. Supplementing The Air Exhausted From Neighboring Rooms Through Ventilation Holes In The Doors. 2.2.4. Air Conditioning Work Should Be Carried Out Regarding All Activities Enabling And Aimed At Implementing The Air Conditioning Installation. - Dismantling The Existing Air Conditioning Installation, - Air-Conditioned Rooms Based On Air Conditioning Systems, - In Stage I All Approaches To The Outdoor And Indoor Units Should Be Made, Along With The Installation Of Outdoor And Indoor Units, Stage Ii Will Include Connecting The Units To The Existing Approaches, Supplementing The Installation With Freon And Commissioning, - Connecting Cooling Units To The Air Handling Units Along With Installing Modules To The Outdoor Air Handling Units, - Drainage Of Condensate From Indoor Units Via Designed Sewage Pipelines To Existing Sewer Lines. Individual Indoor Units Should Be Equipped With Condensate Pumps.2.2.5.Medical Gas Installation: Work Should Be Carried Out Regarding All Activities Enabling And Aimed At Installing Medical Gases. - Dismantling The Existing Medical Gas Installation, - Expansion Of Existing Medical Gas Installations - Gas Installations Medical Devices, In Accordance With Directive 93/42/Eec And National Regulations (Act On Medical Devices Of April 7, 2022, Journal Of Laws No. 2022, Item 974), Are Classified As Class Iib Medical Devices - Directive 93/42/Eec , Must Be Followed During Installation So That The Installation Can Be Ce Marked And Registered As A Medical Device - Oxygen, Compressed Air, Nitrous Oxide And Vacuum Installation Made Of Copper Pipes, - Install A Valve And Control Box And Zone Control Units On The First Floor Signals, - Consumption Points Mainly In Medical Columns, Over-Bed Panels And As Wall Panels. 2.3. Electrical Installations: - Dismantling Of Existing Electrical And Telecommunications Installations In The Area Covered By The Study, - Routing And Internal Connection Of Power Lines That Supply The Electrical Installation In The Area Covered By The Study, - Installation Of Basic And Emergency Lighting, Ensuring Activation Of The Emergency Lighting Installation (Existing Central Battery) By An Authorized Service, - Installation Of Equalizing Connections, Installation Of Plug Sockets And Power Outlets, Cable Routes And Installation Of Electrical Equipment To The Extent Provided For In The Design Documentation, - Ensuring Electrical Switchboards Indicated In The Project, Their Installation And Commissioning As Well As The Necessary Measurements. 2.3.1. Low-Current Installations: A) Telephone Installation B) Logical Installation C) Installation Of The Fire Alarm System) Cctv Installation E) Call System F) Intercom Installation) Intercom Installation H) Access Control2. 4. Elements Of Medical Equipment And Technology: Single-Station Bedside Panel - 11 Sets, Single-Station Bedside Column - 1 Set, Double-Station Bedside Column - 1 Set, Anesthesia Column - 1 Set, Ceiling Lift For Patient Transport 2 Sets. The Ordering Party Requires A Warranty For The Installed Devices For A Minimum Period Of 24 Months.3. The Detailed Scope Of Work Necessary To Be Performed Was Described In The Design Documentation, Bill Of Quantities And Detailed Technical Specifications For The Execution And Acceptance Of Construction Works Constituting Annexes To The Swz.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
9bc51b24-aa99-420a-8030-4ed9bb7ddd3d.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders