GTR 81091721

Bids Are Invited For Registration Of Prices For Possible Provision Of Maintenance Services In The 18 (Eighteen) Medium Voltage Electrical Energy Inputs Of Saae Indaiatuba With The Supply Of Specialized Labor Equipment And Materials

ICB — International Competitive Bid Closed South America
Tender Information
GTR Reference
81091721
Tendering Authority
Subscribe to view
Tender No
26/2024/2024
Financer Name
Self-Funded
Work Title
Bids Are Invited For Registration Of Prices For Possible Provision Of Maintenance Services In The 18 (Eighteen) Medium Voltage Electrical Energy Inputs Of Saae Indaiatuba With The Supply Of Specialized Labor Equipment And Materials
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
15-07-2024 Closed
Work Detail
Receipt Test (Ttr, Megger, Kelvin Bridge), Transformer, Replacement Of The Scraper Sleeve, Replacement Of The 30Kv Rubber Sleeve, Replacement Of The Cabin Isolation Grid, Replacement Of The Cabins Internal Lighting, Replacement Of The 50Mm Bare Cable For Grounding , Replacement Of The Tps Fuse, Replacement Of The Power Transformer 1000Va 25Kv 220V/127V, Replacement Of The 25Kv Current Transformers, Replacement Of The 25Kv Medium Voltage Insulated Cable, Replacement Of The 3/8 Tubular Rebar Terminals, Replacement Of The Busbar Rebar Copper 3/8, Replacement Of The 25Kv Polymeric Insulator, Replacement Of The 25Kv Internal Polymeric Termination, Replacement Of The 25Kv External Polymeric Termination, Replacement Of The Cpfl Pata Tc And Tp Trestle, Replacement Of The 25Kv Polymeric Lightning Arrestors, Replacement Of The 25Kv Porcelain Passage 3/8, Replacement Of The Circuit Breaker Oil Sight Kit, Replacement Of The Circuit Breaker Actuation Handle, Replacement Of The 25Kv Three-Pole Disconnector Switch, Replacement Of The Wheels Of The Circuit Breaker Mechanism Part, Replacement Of The Extender For The Three-Polar Disconnector Switch, Replacement Of The Hh Fuse , Replacement Of 1250A Vacuum Motorized Circuit Breakers, Replacement Of Bijao Type Insulators, Replacement Of Doa 3 Tc, Replacement Of The Ammeter, Replacement Of The Voltmeter, Replacement Of The Qgbt Panel Cabinet, Replacement Of The Qgbt General Circuit Breaker, Replacement Of The Electrolytic Bus, Replacement Of 3 Signals 220V, Replacement Of 2 Faced Buttons, Replacement Of 15 Sak Terminals, Replacement Of 220V Three-Phase Supervisory Relay, Replacement Of 220V Capacitive Trigger, Replacement Of 3 10A Unipolar Circuit Breakers, Replacement Of The Pextron Model 1439 Relay, Replacement Of The Direct Protection Panel Cabinet, Replacement Of The 25Kv 3 Meter Drive Rod, Replacement Of The 30Kv Insulation Mat, Replacement Of The Base For The Hh Fuse, Replacement Of The Support For The Three-Pole Disconnector Switch, Replacement Of The Controller Capacitor Bank, Replacement Of The Circuit Breaker Pole Contact, Replacement Of The Circuit Breaker Kit Gasket For The Circuit Breaker Pole, Replacing The Transformer Switch, Replacing The Gaskets And Rubbers Of The Transformer, Connecting The Closing And Derivations Of The Transformer, Assembling The Hardware Of The Transformer Core, Assembling The Upper Yoke Of The Transformer Core, Assembling New Windings At - H1, H2, H3 Of The Transformer, Assembling New Windings Bt - X1, X2, X3 Of The Transformer, Replacing New Windings Bt - Balls And Geometry Of The Coils Up To -H1, Cleaning The Transformer Core, Removing The Bt Coils From The Transformer Core, Removing The Coils Up From The Transformer Core, Dismantling The Top Yoke From The Core, Removing The Core Hardware, Disassembling The Transformer Switching, Dismantling The At And Bt Connections Of The Transformer, Inspection Of The Active Part Of The Transformer, Disassembly Of The Transformer To Remove The Active Part (Disassembly Of The At, Bt Bushings), Replacement Of The Transformer Wheels, Replacement Of The Arc Voltage Of The Circuit Breaker, Transformer Silicagel Replacement, Voltage Ratio Measurement (Ttr) For Refurbished Transformer, Circuit Breaker Overcurrent Relays Replacement, Circuit Breaker Rear Cover Replacement, Circuit Breaker Side Cover Replacement
Key Value
Tender Value
1,006,893 - BRL
Tender Documents
Global Tender Document
f0554de3-c8a8-4448-a85c-f45626b2b251.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you