GTR 81031161
Tenders Are Invited For Reagents And Consumables For A Modular Analyzer (Cobas 6000 Module E 601 Immunochemiluminescence)
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
81031161
Tendering Authority
Subscribe to view
Tender No
12459471
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Reagents And Consumables For A Modular Analyzer (Cobas 6000 Module E 601 Immunochemiluminescence)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
04-06-2024
Closed
Work Detail
The Acth Calset Calibration Kit Is Intended For Calibrating The Elecsys Acth Quantitative Assay On 4*1 Ml. Reagents And Working Solutions: Acth Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Acth Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Acth (Synthetic) In Two Concentration Ranges (Approximately 15 Pg/Ml And Approximately 120 Pg/Ml ) In The Matrix Of Horse Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Vitamin B12 (Vitamin B12) For 100 Tests. Purpose: Binding Analysis For In Vitro Quantitative Determination Of Vitamin B12 Levels In Human Serum And Plasma. Reagents And Working Solutions: Package With Basic Reagents (M, R1, R2) And Reagents For Pretreatment (Pt1, Pt2) Marked As B12 Ii.Pt1 Reagent 1 For Pretreatment (White Cap), 1 Bottle, 4 Ml: Dithiothreitol 1.028 G/L; Stabilizer, Ph 5.5.Pt2 Reagent 2 For Preliminary Treatment (Grey Cap Colors), 1 Bottle, 4 Ml: Sodium Hydroxide 40 G/L; Sodium Cyanide 2.205 G/L.M Microparticles Coated With Streptavidin (Transparent Cap), 1 Bottle, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative. R1 Internal Factor~Ru(Bpy) (Gray Cap), 1 Bottle, 10 Ml: Recombinant Pig Intrinsic Factor, Labeled With Ruthenium, 4 Μg/L; Cobinamide Dicyanide 15 Μg/L; Stabilizer; Albumin Serum Of Human Blood; Phosphate Buffer, Ph 5.5; Preservative. R2 Vitamin B12~Biotin (Black Cap), 1 Vial, 8.5 Ml: Biotinylated Vitamin B12 25 Μg/L; Biotin 3 Μg/L; Phosphate Buffer, Ph 7.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 5 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 50.0‑2000 Pg/Ml Or 36.9‑1476 Pmol/L (Determined By The Measurement Limit Of The Blank Sample And The Maximum Of The Main Curve). Values Below The Measurement Limit Of The Blank Sample Are Defined As < 50.0 Pg/Ml Or < 36.9 Pmol/L. Values Above The Measurement Range Are Defined As > 2000 Pg/Ml Or > 1476 Pmol/L. Test Reproducibility - No More Than 2.1%., Testosterone Cassette (Testosterone) For 100 Tests. Purpose: Intended For Quantitative Determination Of Testosterone In Serum And Plasma Of Human Blood. Reagents And Working Solutions: The Testo Ii Label Is Affixed To The Package With The Reagent. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Testosterone-Ag~Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Testosterone Antibody (Sheep) 40 Ng/Ml; Releasing Reagent 2-Bromoestradiol; Mes Buffer 50 Mmol/L, Ph 6.0; Preservative R2 Testosterone-Peptide~Ru(Bpy) (Black Cap), 1 Bottle, 9 Ml: Testosterone Derivative Labeled With A Ruthenium Complex 1.5 Ng/Ml; Mes Buffer 50 Mmol/L, Ph 6.0; Preservative Storage Conditions: Unopened At 2‑8 °C Until The End Of The Shelf Life. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The C-Peptide Calset Calibration Set Is Intended For The Calibration Of The C-Peptide Quantitative Assay. Reagents And Working Solutions: ▪ Cpeptid Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Cpeptid Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 C-Peptide (Synthetic) In Two Concentration Ranges (Approximately 0.167 Nmol/L Or 0.5 Ng /Ml And Approximately 6.67 Nmol/L Or 20 Ng/Ml) In The Horse Serum Matrix. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Cancer-Embryonic Antigen (Cea) For 100 Tests. Purpose: Intended For Quantitative Determination Of Carcinoembryonic Antigen In Human Serum And Plasma. This Assay Is Indicated For Serial Measurement Of Cea As An Adjunctive Method For Monitoring Patients With Cancer. Reagents And Working Solutions: The Cea Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 8 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Cea-Antibodies~Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Cea Antibodies (Mouse/Human) 3.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.0; Preservative R2 Anti-Cea-Ab~Ru(Bpy) (Black Cap), 1 Vial, 8 Ml: Monoclonal Anti-Cea Antibodies (Mouse), Labeled With A Ruthenium Complex 4.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.5; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 4 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.200-1000 Ng/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Reference Calibration Curve). Values Below The Detection Limit Are Defined As < 0.200 Ng/Ml. Values Above The Measurement Range Are Defined As > 1,000 Ng/Ml (Or Up To 50,000 Ng/Ml For Samples With A 50-Fold Dilution). Test Reproducibility - No More Than 1.3%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., The Folate Iii Calset Calibration Kit Is Intended For Calibrating The Elecsys Folate Iii Quantitative Assay On Elecsys And Cobas E Immunochemical Analyzers. Reagents And Working Solutions: Fol Iii Cal1: 2 Bottles, Each With 1.0 Ml Of Calibrator 1 ▪ Fol Iii Cal2: 2 Bottles, Each With 1.0 Ml Of Calibrator 2 Folic Acid Salt In Two Concentration Ranges. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Immunoglobulin M To Cytomegalovirus (Cmv Igm) For 100 Tests. Purpose: Intended For The Qualitative Determination Of Igm Antibodies To Cytomegalovirus In Human Serum And Plasma. Reagents And Working Solutions: The Package With The Main Reagents (M, R1, R2) Is Labeled Cmvigm. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-H-Igm-Ab~Biotin (Gray Cap), 1 Vial, 9 Ml: Biotinylated Monoclonal Anti-H-Igm Antibody (Mouse) > 500 Μg/L, Mes Buffer 50 Mmol/L, Ph 6.5; Preservative. R2 Cmv-Ag~Ru(Bpy) (Black Cap), 1 Bottle, 9 Ml: Cmv-Specific Antigen (Recombinant, E. Coli), With A Ruthenium Mesium Complex > 50 Μg/L, Mes-Buffer 50 Mmol/L, Ph 5.5; Preservative.Cmvigm Cal1 Negative Calibrator 1 (White Cover), 2 Fl. For 1.0 Ml Each: Human Blood Serum, Which Does Not Contain Anti-Cmv Igm Antibodies; Preservative Cmvigm Cal2 Positive Calibrator 2 (Black Cap), 2 Vials Of 1.0 Ml Each: Anti-Cmv Igm (Human Blood Serum) In Hepes Buffer, Ph 7.4; Beef Albumin; Preservative Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.25‑500 U/Ml (Determined By The Value Of The Detection Limit And The Maximum Value Of The Master Calibration). Values Below The Measurement Limit Of The Blank Sample Are Displayed As < 0.15 U/Ml. The Device Does Not Flag Values Higher Than The Measurement Limit Blank Sample, But Below The Detection Limit. Values Above The Measurement Range Are Displayed As > 500 U/Ml (Or Up To 10,000 U/Ml For 20-Fold Dilution Samples). Test Reproducibility - No More Than 1.7%., The Calset Ii Fsh Calibration Kit Is Intended For Calibrating A Quantitative Fsh Test. Reagents And Working Solutions: ▪ Fsh Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Fsh Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Follicle-Stimulating Hormone (Human) In Two Concentration Ranges (Approximately 1 Miu/Ml And Approximately 55 Miu /Ml) In The Horse Serum Matrix. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Anti-Tpo Calset Calibration Set Is Intended For Calibrating The Elecsys Anti-Tpo Quantitative Test. Reagents And Working Solutions: Anti-Tpo Cal1: 2 Vials, Each For 1.5 Ml Of Calibrator 1 ▪ Anti-Tpo Cal2: 2 Vials, Each For 1.5 Ml Of Calibrator 2 Anti-Tpo Antibodies (Sheep) In Two Concentration Ranges (Approximately 35 Iu/ Ml And Approximately 350 Iu/Ml) In The Matrix Of Human Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Tumor Antigen 125 (Ca 125) For 100 Tests. Purpose: Intended For Quantitative Determination Of Reactive Epitopes Of Os 125 In Human Serum And Plasma. Reagents And Working Solutions: The Label Ca125 Ii Is Affixed To The Package With Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Ca 125-Antibody-Biotin (Gray Cap), 1 Vial, 9 Ml: Biotinylated Monoclonal Anti-Ca 125-Antibody (M 11; Mouse) 1 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative R2 Anti-Ca 125-Antibodies~Ru(Bpy) (Black Cap), 1 Vial, 9 Ml: Monoclonal Anti-Ca 125 Antibody (Os 125, Mice), Labeled With A Ruthenium Complex 1 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative Storage Conditions: Unopened At 2‑8 °C Until The End Of The Shelf Life. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Solution Probe Wash M 12 Bottles Of 70 Ml. Probewash M Is Used To Perform The Following Tasks: ▪ Cleaning Of The Reagent Sample Probe At The End Of The Series ▪ Cleaning Of The Reagent Sample During The Replacement Of Reagents For Some Analyses. Reagents And Working Solutions: 12 X 70 Ml, Solution For Cleaning The Probe For Taking The Reagent Koh 176 Mmol/L (Sootvetstvuet Рн 13.2); Detergent ≤ 1%. Storage And Transportation Conditions: Store At Room Temperature. The Storage Period Of The Opened Reagent In The Refrigerated Compartment For Reagents On Board The Analyzer Is 1 Week. Do Not Subject To Mechanical Impact, Do Not Expose To Freezing Or High Temperature. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Anti-Tg Calset Calibration Set Is Intended For The Calibration Of The Elecsys Anti-Tg (Thyroglobulin) Quantitative Assay. Reagents And Working Solutions: A-Tg Cal1: 2 Vials, Each For 1.5 Ml Of Calibrator 1 ▪ A-Tg Cal2: 2 Vials, Each For 1.5 Ml Of Calibrator 2 Anti-Tg Antibodies (A-Tg Cal1: Human, A-Tg Cal2 : Sheep) In Two Concentration Ranges (Approximately 40 Iu/Ml And Approximately 3250 Iu/Ml) In The Matrix Of Human Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Vitamin D Total Calset Calibration Set Is Intended For The Calibration Of The Elecsys Vitamin D Total Quantitative Analysis ▪ Vit‑D Total Cal1: 2 Vials, Each 1.0 Ml Of Calibrator 1 ▪ Vit‑D Total Cal2: 2 Vials, Each 1.0 Ml Of Calibrator 2 25‑Oh Vitamin D3 In Two Concentration Ranges (Approximately 3 Ng/Ml Or 7.5 Nmol/L And Approximately 45 Ng/Ml Or 113 Nmol/L) In The Matrix Of Human Blood Serum; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Precicontrol Varia Set (A Set Of Control Sera) Is Intended For Quality Control Of Elecsys Tests By The Immunochemical Method On Elecsys And Cobas E Analyzers. Reagents And Working Solutions: Pc V1: 2 Vials, Each For 3.0 Ml Of Control Serum ▪ Pc V2: 2 Vials, Each For 3.0 Ml Of Control Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Ca 72‑4 Calset Calibration Set Is Intended For Calibrating The Ca 72‑4 Quantitative Analyzer. Reagents And Working Solutions: Ca72‑4 Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Ca72‑4 Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Ca 72‑4 (Human) In Two Concentration Ranges (Approximately 1 U/ Ml And Approximately 70 U/Ml) In The Matrix Of Human Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Ca 125 Ii Calset Ii Calibration Kit Is Intended For Calibrating The Elecsys Ca 125 Ii Quantitative Analyzer. Reagents And Working Solutions: Ca125 Ii Cal1: 2 Bottles, Each 1.0 Ml Of Calibrator 1 ▪ Ca125 Ii Cal2: 2 Bottles, Each 1.0 Ml Of Calibrator 2 The Concentration Of Human Ca 125 In The Horse Serum Matrix (Ca125 Ii Cal1) Is 0 U/Ml ; Ca125 Ii Cal2 Contains Approximately 500 U/Ml Of Human Ca 125 In A Human Serum Matrix; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Calibration Kit Estradiol Ii Calset Ii Is Intended For Calibration Of The Quantitative Analysis Of Estradiol Ii. Reagents And Working Solutions: E2 Iii Cal1: 2 Vials, Each 1.0 Ml Of Calibrator 1 ▪ E2 Iii Cal2: 2 Vials, Each 1.0 Ml Of Calibrator 2 Estradiol (Synthetic) In Two Concentration Ranges (Approximately 73 Pmol/L Or 20 Pg/ Ml And Approximately 7340 Pmol/L Or 2000 Pg/Ml) In The Matrix Of Human Blood Serum; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cleancell M Solution For The Cobas 6000 2X2 L Analyzer. Purpose: The System Solution For Cleaning The Measuring Device Of The Cobas 6000 Cleancell Immunological Analyzers Is Used When Performing Tests Using Elecsys Reagents. The Cleancell Kit Can Be Used With All Reagent Series. Reagents And Working Solutions: 6 X 380 Ml, Cleaning Solution For The Measuring Cell Koh 176 Mmol/L (Corresponds To Ph 13.2); Detergent ≤ 1%. Storage And Transportation Conditions: Store At Room Temperature In A Strictly Vertical Position. Shelf Life At 15-25 °C See The Shelf Life On The Kit Label. Transportation Must Be In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Calibrator Human Chorionic Gonadotropin Intact+Beta-Subunit Ii (Hcg+Beta Ii Cs). The Hcg+Β Calset Calibration Kit Is Intended For The Calibration Of The Quantitative Analysis Elecsys Hcg+Β 4*1 M. Reagents And Working Solutions: Hcg+Β Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Hcg+Β Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Human Chorionic Gonadotropin (From Urine) In Two Concentration Ranges (Approx. 1.5 Miu/Ml And Approx. 2000 Miu/Ml) In Buffered Human Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Follikulin-Stimulating Hormone Fsh (Follicle-Stimulating Hormone) For 100 Tests. Purpose: Test For Quantitative Determination Of Follicle-Stimulating Hormone In Human Blood Serum And Plasma. Reagents And Working Solutions: The Fsh Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Fsh Antibody~Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Fsh Antibodies (Mouse) 0.5 Mg/L; Mes Buffer 50 Mmol/L, Ph 6.0; Preservative R2 Anti-Fsh-Antibody~Ru(Bpy) (Black Cap), 1 Vial, 10 Ml: Monoclonal Anti-Fsh Antibodies (Mouse), Labeled With A Ruthenium Complex 0.8 Mg/L; Mes Buffer 50 Mmol/L, Ph 6.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.100-200 Miu/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Master Calibration). Values Below The Detection Limit Are Displayed As < 0.100 Miu/Ml. Values Above The Measurement Range Are Displayed As > 200 Miu/Ml. Lower Limits Test Reproducibility - No More Than 1.5%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., The Free Psa Calset Calibration Set Is Intended For The Calibration Of The Free Psa Quantitative Analysis. Reagents And Working Solutions: ▪ Fpsa Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Fpsa Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Free Psa (Human) In Two Concentration Ranges (Approximately 0.10 Ng/Ml And Approximately 20 Ng /Ml) In A Buffer/Protein Matrix (Bovine Serum Albumin). Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Afp Calset Ii Calibration Set Is Intended For Calibrating The Elecsys Afp Quantitative Analyzer On 4*1 Ml. Reagents And Working Solutions: Afp Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 Afp Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Afp (Human, From Cell Culture) In Two Concentration Ranges (Approximately 5 Iu/Ml Or 6 Ng) /Ml And Approximately 50 Iu/Ml Or 60 Ng/Ml) In Human Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Calset Tsh Calibration Kit Is Intended For Calibrating The Elecsys Tsh Quantitative Analyzer. Reagents And Working Solutions: Tsh Cal1: 2 Vials Each For 1.3 Ml Calibrator 1 ▪ Tsh Cal2: 2 Vials Each For 1.3 Ml Calibrator 2 The Concentration Of Tsh Cal1 In The Horse Serum Matrix Is Approximately 0 Μiu/Ml: Tsh Cal2 Is Approximately 1.5 Μiu/Ml Tsh (Human) In Human Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Universal Diluent 2Х36 Ml. Purpose: Diluent Universal Is Used To Dilute The Sample When Performing Tests Using Elecsys Reagents. Reagents And Working Solutions: Diluent Universal Is Marked As Dil. Uni. 2 Bottles, 32 Ml Each. Contents: Protein Matrix; Preservative ≤ 0.1% Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Cea Calset Calibration Kit Is Intended For The Calibration Of A Quantitative Cea Assay. Reagents And Working Solutions: ▪ Cea Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Cea Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Cea (Human, From Cell Culture) In Two Concentration Ranges (Approximately 5 Ng/Ml And Approximately 50 Ng/Ml) In The Buffer/Protein Matrix. 1 Ng/Ml Cea Corresponds To 16.9 Miu/Ml. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Triiodothyronine Free (Ft3) 200 Tests. Purpose: It Is Intended For The Quantitative Determination Of The Content Of Free Triiodothyronine In The Serum And Plasma Of Human Blood. Reagents And Working Solutions: The Label Ft3 Iii Is Affixed To The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 12 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-T3-Antibody~Ru(Bpy) (Gray Cap), 1 Vial, 18 Ml: Monoclonal Anti-T3-Antibodies (Sheep), Labeled With A Ruthenium Complex 18 Ng/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative R2 T3~Biotin (Black Cap), 1 Bottle, 18 Ml: Biotinylated T3 2.4 Ng/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used Onboard The Analyzer At 10-15°C 6 Weeks. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Measurement Range 0.4‑50 Pmol/L. The Lower Detection Limit Of The Test Is 0.6 Pmol/L. Test Reproducibility - No More Than 2%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Preclean M Solution 5X600 Ml. Preclean M Is Used To Remove Potentially Dangerous Substances Before The Appearance Of Signals - The Last Step Of The Analytical Procedure. Reagents And Working Solutions: 5 X 600 Ml Of Washing Solution Phosphate Buffer 10 Mmol/L; Sodium Chloride 20 Mmol/L; Detergent ≤ 0.1%; Preservative; Ph 7.0. Storage And Transportation Conditions: Store At Room Temperature In A Strictly Vertical Position. Shelf Life At 15-25 °C See The Shelf Life On The Kit Label. Transportation Must Be In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Precicontrol Hbsag Ii Kit (Control Sera Kit) Is Intended For Quality Control Of Elecsys Hbsag Ii Tests. Reagents And Working Solutions: ▪ Pc Hbsagii1: 8 Vials, Each Containing 1.3 Ml Of Control Serum Human Blood Serum Negative For Antibodies To The Hepatitis B Virus (Hbsag); Preservative Range Of Target Values Of The Discriminative Level Index: 0.0‑0.80 Quantitative Target Range: 0.0‑0.05 Iu/Ml ▪ Pc Hbsagii2: 8 Vials, Each Containing 1.3 Ml Of Control Serum Hbsag (Human) Approximately 0.2 Iu/Ml In Human Blood Serum; Preservative The Range Of Target Values Of The Discriminative Level Index: 2.6‑5.0 Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Estradiol (Estradiol) For 100 Tests. Purpose: Intended For Quantitative Determination Of Estradiol In Serum And Plasma Of Human Blood. Reagents And Working Solutions: The E2 Iii Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Estradiol-Ab~Biotin (Gray Stopper), 1 Vial, 9 Ml: Two Biotinylated Monoclonal Antibodies Against Estradiol (Rabbit) 2.5 Ng/Ml And 4.5 Ng/Ml; Mesterolone 130 Ng/Ml; Buffer Solution Mesb) 50 Mmol/L, Ph 6.0; Preservative R2 Estradiol-Peptide~Ru(Bpy) (Black Cap), 1 Vial, 9 Ml: Estradiol Derivative Labeled With A Ruthenium Complex 4.5 Ng/Ml; Mes Buffer 50 Mmol/L, Ph 6.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 18.4-11010 Pmol/L (5-3000 Pg/Ml) (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Master Calibration). Values Below The Detection Limit Are Defined As < 18.4 Pmol/L Or < 5 Pg/Ml. Values Above The Measurement Range Are Defined As > 11010 Pmol/L Or > 3000 Pg/Ml (Or Up To 110100 Pmol/L Or 30000 Pg/Ml For Samples With 10-Fold Dilution). Test Reproducibility Is No More Than 1.9%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Disposable Tips And Microcaps For Cobas E601. The Package Contains 8 Sets Of 6 Pallets With Tips And Microdrops. Each Pallet Contains 84 Tips And 84 Microcaps. The Tips Are Made Of Opaque Conductive Material, Have A Sharp Conical Shape, Diameter 7 Mm, Length 55 Mm. Microcaps Are Made Of Transparent Dielectric Material, Diameter 7 Mm, Length 45 Mm. Each Set Is Packed In A Hermetic Film. Storage And Transportation Conditions: Store At Room Temperature. Shelf Life At 15-25 °C See The Shelf Life On The Kit Label. Do Not Expose To Mechanical Impact, Frost Or High Temperature. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Procell M Solution For The Cobas 6000 2X2 L Analyzer. Purpose: System Solution For Generating Electrochemical Signals In Immunological Analyzers Modular Analytics E170, Cobas E 601 And Cobas E 602. Reagents And Working Solutions: 2 X 2 L System Buffer Phosphate Buffer 300 Mmol/L , Tripropylamine 180 Mmol/L; Detergent ≤ 0.1%; Preservative, Ph 6.8. Storage And Transportation Conditions: Store At Room Temperature In A Strictly Vertical Position. Shelf Life At 15-25 °C See The Shelf Life On The Kit Label. Transportation Must Be In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Precicontrol Cmv Igg Kit (Control Sera Kit) Is Intended For Quality Control Of Elecsys Cmv Igg Tests. Reagents And Working Solutions: ▪ Pc Cmvigg1: 8 Bottles, Each Containing 1.0 Ml Of Control Serum Human Blood Serum Weakly Positive For Cmv Igg Antibodies (Approximately 1.5 U/Ml); Preservative ▪ Pc Cmvigg2: 8 Vials, Each Containing 1.0 Ml Of Control Serum Human Blood Serum Positive For Cmv Igg Antibodies (Approximately 25 U/Ml); Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Calibrator Insulin (Insulin Cs). The Insulin Calset Calibrator Set Is Intended For Calibrating The Elecsys Insulin Quantitative Test. Reagents And Working Solutions: Insulin Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Insulin Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Insulin (Recombinant Human From Yeast) In Two Concentration Ranges (Approximately 5 Μu/Ml Or 35 Pmol /L And Approximately 300 Μu/Ml Or 2080 Pmol/L) In The Bovine Serum Matrix. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Fragment Cytokeratin 19 (Cyfra 21-1) For 100 Tests. Purpose: Intended For Quantitative Determination Of Cytokeratin 19 Fragments In Human Serum And Plasma. Reagents And Working Solutions: The Cyfra Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Cytokeratin 19-Ab~Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Cytokeratin 19-Antibody (Ks 19.1; Mice), 1.5 Mg/L, Phosphate Buffer 100 Mmol/L, Ph 7.2; Preservative R2 Anti-Cytokeratin 19-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Anti-Cytokeratin 19 Antibodies (Bm 19.21; Mice), Labeled With A Ruthenium Complex 2 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.2; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.100-500 Ng/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Reference Calibration Curve). Values Below The Detection Limit Are Defined As < 0.100 Ng/Ml. Values Above The Measurement Range Are Defined As > 500 Ng/Ml (Or Up To 1000 Ng/Ml For Samples With 2-Fold Dilution). Test Reproducibility - No More Than 1.7%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Cassette: Free Thyroxine Ft4 S For 200 Tests. Purpose: Intended For Quantitative Determination Of Unbound Thyroxine In Serum And Plasma Of Human Blood. Reagents And Working Solutions: The Ft4 Ii Label Is Affixed To The Package With Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 12 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-T4-Ab~Ru(Bpy) (Gray Cap), 1 Vial, 18 Ml: Polyclonal Anti-T4 Antibodies (Sheep), Labeled With A Ruthenium Complex 75 Ng/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative R2 T4~Biotin (Black Cap), 1 Bottle, 18 Ml: Biotinylated T4 2.5 Ng/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative Storage Conditions: Unopened At 2‑8 °C Until The End Of The Shelf Life. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Precicontrol Multimarker Set Is Intended For Quality Control Of The Listed Immunoassays. Reagents And Working Solutions: ▪ Pc Mm1: 3 Vials, Each Containing 2.0 Ml Of Control Serum ▪ Pc Mm2: 3 Vials, Each Containing 2.0 Ml Of Control Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Testosterone Ii Calset Ii Calibration Kit Is Intended For Calibrating The Elecsys Testosterone Ii Quantitative Test. Reagents And Working Solutions: ▪ Testo Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Testo Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Testosterone (From Plant Material) In Two Concentration Ranges (Approximately 0.4 Ng/Ml Or 40 Ng /Dl Or 1.4 Nmol/L And Approximately 11.5 Ng/Ml Or 1150 Ng/Dl Or 40 Nmol/L) In Human Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Tacrolimus Calibrator For Each Of Calibrators 1 And 2 (Tacrolimus Calset). Purpose: The Calibrator For Automated Systems Is Intended For The Calibration Of Roche Tests For The Quantitative Determination Of One Or More Proteins Of Roche Clinical Chemistry, In Accordance With The Passports Of The Assigned Values. Reagents And Working Solutions: Human Blood Serum With Chemical Additives And Biological Material Conditions Of Storage And Transportation: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. Storage Conditions: Store At 2‑8 °C. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Antibodies To Thyroperoxidase (Anti-Tpo) For 100 Tests. Purpose: It Is Intended For The Quantitative Determination Of The Content Of Antibodies To Thyroid Peroxidase In Human Serum And Plasma. Determination Of Anti-Tpo Is Used As An Auxiliary Method For Diagnosing Autoimmune Thyroiditis. Reagents And Working Solutions: The A‑Tpo Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Tpo-Antibodies~Ru(Bpy) (Gray Cap), 1 Vial, 9 Ml: Polyclonal Anti-Tpo-Antibodies (Sheep), Labeled With A Ruthenium Complex 1.0 Mg/L; Tris Buffer 100 Mmol/L, Ph 7.2; Preservative R2 Tpo~Biotin (Black Cap), 1 Bottle, 9 Ml: Biotinylated Tpo (Recombinant) 0.15 Mg/L; Tris-Buffer 30 Mmol/L, Ph 7.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 2 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Calibration Frequency Is Daily. Measurement Range 5.00-600 Iu/Ml. The Lower Detection Limit Of The Test < 5.0 Iu/Ml. Test Reproducibility - No More Than 2.5%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Immunoglobulin G Of Herpes Simplex Virus Type 1 (Hsv-1 Igg) For 100 Tests. Purpose: Intended For The Qualitative Determination Of Igg Class Antibodies To The Hsv-1 Virus In Human Serum And Plasma. It Is Used To Assess The Immune Status And To Diagnose Hsv Infection. Reagents And Working Solutions: The Packaging With The Main Reagents (M, R1, R2) Has An Hsv‑1 Label. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Hsv-1-Ag~Biotin (Gray Cap), 1 Vial, 9 Ml: Biotinylated Hsv-1-Specific Antigen (Recombinant, E. Coli), > 150 Μg/L, Mesb)-Buffer 50 Mmol/L, Ph 6.5; Preservative R2 Hsv-1-Ag~Ru(Bpy) (Black Cap), 1 Vial, 9 Ml: Hsv-1-Specific Antigen (Recombinant, E. Coli), Labeled With A Ruthenium Complex > 150 Μg/L, Mes-Buffer 50 Mmol /L, Ph 6.5; Preservative B) Mes = 2-Morpholino-Ethanesulfonic Acid Hsv‑1 Cal1 Negative Calibrator 1 (White Cap), 2 Vials (Lyophilized) For 1.0 Ml Each: Human Serum, Non-Reactive To Igg Antibodies To Hsv-1; Preservative Hsv‑1 Cal2 Positive Calibrator 2 (Black Cap), 2 Vials (Lyophilized) For 1.0 Ml Each: Human Blood Serum Reactive For Igg Antibodies To Hsv-1; Preservative Shelf Life At 2‑8 °C See 8 Weeks When Used Onboard The Analyzer At 10‑15 °C. Transportation In Thermocontainers With Cooling Elements At A Temperature Of 2-8 °C, Calibration Is Linear At Two Points, Calibration Frequency - 7 Days. The Measurement Range Is 0.25‑500 U/Ml (Determined By The Value Of The Detection Limit And The Maximum Value Of The Master Calibration). Values Below The Measurement Limit Of The Blank Sample Are Displayed As < 0.15 U/Ml. The Device Does Not Flag Values Higher Than The Measurement Limit Blank Sample, But Below The Detection Limit. Values Above The Measurement Range Are Displayed As > 500 U/Ml (Or Up To 10,000 U/Ml For 20-Fold Dilution Samples). Test Reproducibility - No More Than 1.4%., The Set Of Precicontrol Universal Control Sera Is Intended For Elecsys Quality Control By Immunochemical Method On Elecsys And Cobas E Analyzers. Reagents And Working Solutions: The Precicontrol Universal Kit Contains Lyophilized Control Serum Based On Human Blood Serum In Two Concentration Ranges. Controls Are Used To Monitor The Accuracy And Reproducibility Of Elecsys Immunoassays. Reagents - Working Solutions ▪ Pc U1: 2 Fl. For 2 X 3.0 Ml Of Control Blood Serum (Human) ▪ Pc U2: 2 Fl. For 2 X 3.0 Ml Of Control Blood Serum (Human). Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Pth Calset Calibration Set Is Intended For Calibrating The Elecsys Pth Quantitative Analysis. Reagents And Working Solutions: ▪ Pth Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Pth Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Pth (Synthetic Peptide, Human Sequence) In Two Concentration Ranges (Approximately 0.005 Pmol/L Or 0.05 Pg/Ml And Approximately 477 Pmol/L Or 4500 Pg/Ml) In A Human Serum Matrix; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Ca 19‑9 Calset Calibration Set Is Intended For The Calibration Of Quantitative Ca 19‑9. Reagents And Working Solutions: ▪ Ca19‑9 Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Ca19‑9 Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Ca 19‑9 (Human) In Two Concentration Ranges (Approximately 20 U /Ml And Approximately 250 U/Ml) In The Matrix Of Human Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Diluent Multiassay Diluent Multiassay For Cobas E, Elecsys Analyzers 2*18 Ml. Purpose: Diluent Multiassay Is Used To Dilute The Sample When Performing Tests Using Elecsys Reagents. Reagents And Working Solutions: 2 Vials, 16 Ml Each Contents: Horse Serum Matrix In Buffer; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Cyfra 21‑1 Calset Calibration Kit Is Intended For The Calibration Of The Cyfra 21‑1 Quantitative Analyzer. Reagents And Working Solutions: Cyfra Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Cyfra Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Cytokeratin (Human, From The Mcf-7 Cell Line) In Two Concentration Ranges (Approximately From 0 Ng /Ml To 50 Ng/Ml) In The Matrix Of Human Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Intact Human Chorionic Gonadotropin +Beta-Subunit-Hcg+Beta Ii Cassette For 100 Tests. Purpose: This Test Is Used: ▪ For Early Detection And Monitoring Of Pregnancy. In Combination With Other Parameters When Assessing The Risk Of Down Syndrome (Trisomy 21 Chromosomes). For The Diagnosis Of Chromosomal Aberrations, Further Examination Is Necessary. ▪ In Oncology, The Definition Of Hcg+Β Is Used To Manage Patients With Trophoblastic Tumors. This Test Is Used To Detect And Monitor Hcg-Producing Tumor Cells Of Ovarian, Placental, Or Testicular Origin. Reagents And Working Solutions: M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Hcg-Antibody~Biotin (Gray Cap), 1 Vial, 9 Ml: Biotinylated Monoclonal Anti-Hcg Antibodies (Mouse) 2.6 Mg/L; Phosphate Buffer 40 Mmol/L, Ph 7.5; Preservative R2 Anti-Hcg Antibodies~Ru(Bpy) (Black Cap), 1 Vial, 10 Ml: Monoclonal Anti-Hcg Antibodies (Mouse), Labeled With A Ruthenium Complex 4.6 Mg/L; Phosphate Buffer 40 Mmol/L, Ph 6.5; Preservative. Storage Conditions: Unopened At 2‑8 °C Until The End Of The Shelf Life. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Total Antibodies To Viral Hepatitis C (Anti-Hcv) For 200 Tests. Purpose: The Elecsys Anti-Hcv Ii Assay Is An In Vitro Diagnostic Test For The Qualitative Determination Of Antibodies To The Hepatitis C Virus (Hcv) In Human Serum And Plasma. Reagents And Working Solutions: The Package With The Main Reagents (M, R1, R2) Is Labeled A-Hcv Ii. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Hcv-Specific Antigens~Biotin (Gray Cap), 1 Vial, 18 Ml: Biotinylated Hcv-Specific Antibodies, Hepesb) Buffer, Ph 7.4; Preservative R2 Hcv-Specific Antigens~Ru(Bpy) (Black Cap), 1 Vial, 18 Ml: Hcv-Specific Antigens Labeled With A Ruthenium Complex ≥ 0.3 Mg/L, Hepes Buffer, Ph 7.4; Preservative B) Hepes = [4-(2-Hydroxyethyl)-Piperazine]-Ethanesulfonic Acid A-Hcv Ii Cal1 Negative Calibrator 1 (White Cap), 2 Vials Of 1.3 Ml: Human Serum, Preservative. A-Hcv Ii Cal2 Positive Calibrator 2 (Black Cap), 2 Vials Of 1.3 Ml: Human Serum, Positive Anti-Hcv Ab Antibody; Preservative Non-Reactive For Hbsag, Anti-Hiv 1/2. Shelf Life At 2‑8 °C See 8 Weeks When Used Onboard The Analyzer At 10‑15 °C. Transport In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.25‑500 U/Ml (Determined By The Value Of The Detection Limit And The Maximum Value Of The Master Calibration). Values Below The Measurement Limit Of The Blank Sample Are Displayed As < 0.15 U/Ml. The Device Does Not Flag Values Higher Than The Measurement Limit Blank Sample, But Below The Detection Limit. Values Above The Measurement Range Are Displayed As > 500 U/Ml (Or Up To 10,000 U/Ml For 20-Fold Dilution Samples). Test Reproducibility - No More Than 2.2%., Cassette Antibodies To Thyroglobulin (Anti-Tg) For 100 Tests. Purpose: Immunoassay With The Aim Of In Vitro Quantitative Determination Of The Content Of Antibodies To Thyroglobulin In Human Serum And Plasma. Determination Of Anti-Tg Is Used As An Auxiliary Method For Diagnosing Autoimmune Thyroiditis. Reagents And Working Solutions: The A-Tg Label Is Affixed To The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 12 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Tg~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Tg (Human) 0.200 Mg/L; Tris Buffer 100 Mmol/L, Ph 7.0; Preservative R2 Anti-Tg-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Anti-Tg Antibodies (Human) Labeled With A Ruthenium Complex 0.620 Mg/L; Tris Buffer 100 Mmol/L, Ph 7.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used Onboard The Analyzer At 10-15°C 6 Weeks. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is After Changing The Lot. Measurement Range 10.0-4000 Iu/Ml. The Lower Detection Limit Of The Test < 10.0 Iu/Ml. Test Reproducibility - No More Than 4%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cleaning Solution For Ion-Selective Electrodes (Ise Cleaning Solution Sys Clean) 5X100 Ml. For Cleaning Ise Modules On Roche/Hitachi Analyzers. For Cleaning Immunological Analyzers Elecsys And Cobas E. Reagents And Working Solutions: 5 Bottles, Each 100 Ml. Components: Sodium Hydroxide, 3 Mol/L Sodium Hypochlorite Solution. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Calibration Kit Total Psa Calset Ii Is Intended For The Calibration Of Total Psa Quantitative Analysis Reagents And Working Solutions: Psa Cal1: 2 Bottles, Each 1.0 Ml Of Calibrator 1 ▪ Psa Cal2: 2 Bottles, Each 1.0 Ml Of Calibrator 2 Psa (Human) In Two Ranges Concentrations (Approximately 0 Ng/Ml And Approximately 60 Ng/Ml) In The Matrix Of Human Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Control Precicontrol Cyclosporine And Tacrolimus (Precicontrol Isds For Each Precicontrol Isd 1,2 And 3 (Whole Blood Based). Purpose: The Set Is Intended For Use During Quality Control Procedures, As It Allows Determining The Accuracy Of Quantitative Methods Specified In Special Documents. Reagents И Рабочие Растровы: Reactive Components In Lyophilisate: Human Serum With Chemical Additives And Material Of Biological Origin, In Accordance With The Specified Data Shelf Life On The Label Of The Cobas C Kit. When Used On Board The Analyzer At 10-15 ° C, One-Time Use, When Frozen, It Is Necessary To Transport In Thermal Containers At A Temperature Of 2-8 ° C, Strictly In A Vertical Position, Do Not Expose To High Temperatures Reagents For The Cobas E601 Analyzer. The Supplier Must Provide A Certificate Of Origin. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Precicontrol Troponin Is Used To Control The Quality Of The Elecsys Troponin T Hs, Elecsys Troponin T Hs Stat, Elecsys Troponin I And Elecsys Troponin I Stat Immunoassays Using The Analyzers For Conducting. Reagents And Working Solutions: ▪ Pc Tn1: 2 Vials For 2.0 Ml Control Serum Each ▪ Pc Tn2: 2 Vials For 2.0 Ml Control Serum Each Troponin T (Recombinant, Human) In Two Concentration Ranges (Approximately 30 Ng/L Or Pg/Ml And Approximately 2500 Ng/L Or Pg/Ml) And Troponin I (Recombinant, Human) In Two Concentration Ranges (Approximately 0.75 Μg/L Or Ng/Ml And Approximately 18 Μg/L Or Ng/Ml) In The Matrix Of Human Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Thyroid-Stimulating Hormone (Tsh) Cassette For 200 Tests. Purpose: Intended For Quantitative Determination Of Thyrotropin In Serum And Plasma Of Human Blood. Reagents And Working Solutions: The Tsh Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 12 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Tsh Antibodies~Biotin (Gray Cap), 1 Bottle, 14 Ml: Biotinylated Monoclonal Anti-Tsh Antibodies (Mouse) 2.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.2; Preservative R2 Anti-Tsh-Ab~Ru(Bpy) (Black Cap), 1 Vial, 12 Ml: Monoclonal Anti-Tsh Antibodies (Mouse/Human), Labeled With A Ruthenium Complex 1.2 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.2; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.300-10.0 Nmol/L Or 0.195-6.51 Ng/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Reference Calibration Curve). The Values Are Below The Limit Detections Are Defined As < 0.300 Nmol/L Or < 0.195 Ng/Ml. Values Above The Measurement Range Are Defined As > 10.0 Nmol/L Or > 6.51 Ng/Ml. Test Reproducibility - No More Than 2.5%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Parathyroid Hormone Pth Cassette For 100 Tests. Purpose: Intended For Quantitative Determination Of Intact Parathyroid Hormone In Human Serum And Plasma For Differential Diagnosis Of Hypercalcemia And Hypocalcemia. The Elecsys Pth Test Can Be Used During Surgery. Reagents And Working Solutions: The Pth Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Pth-Antibody~Biotin (Gray Cap), 1 Vial, 7 Ml: Biotinylated Monoclonal Anti-Pth-Antibodies (Mouse) 2.3 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative R2 Anti-Pth-Antibody~Ru(Bpy) (Black Cap), 1 Bottle, 7 Ml: Monoclonal Anti-Pth-Antibodies (Mouse), Labeled With A Ruthenium Complex 2.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 1.20-5000 Pg/Ml Or 0.127-530 Pmol/L (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Reference Calibration Curve). Values Below The Detection Limit Are Defined As < 1.20 Pg/Ml (< 0.127 Pmol/L). Values Above The Measurement Range Are Defined As > 5000 Pg/Ml (> 530 Pmol/L). Test Reproducibility - No More Than 1.7%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Cassette Tumor Antigen 72-4 (Ca 72-4) For 100 Tests. Purpose: Intended For Quantitative Determination Of Ca 72‑4 In Serum And Plasma Of Human Blood. This Method Is Used In Particular For Therapeutic Monitoring Of Gastric And Ovarian Carcinomas. Reagents And Working Solutions: The Label Ca72‑4 Is Affixed To The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Ca 72-4-Ab~Biotin (Gray Cap), 1 Vial, 8 Ml: Biotinylated Monoclonal Anti-Ca 72-4-Antibody (Cc49; Mice), 1 Mg/L, Phosphate Buffer 100 Mmol/L, Ph 6.8; Preservative. R2 Anti-Ca 72-4-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 8 Ml: Monoclonal Anti-Ca 72-4 Antibodies (B72.3; Mice), With A Mechenieruthenium Complex 6 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.8; Preservative Storage Conditions: Unopened At 2‑8 °C Until The End Of The Shelf Life. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Precicontrol Tumor Marker Set (A Set Of Control Sera) Is Intended For Quality Control Of Elecsys Tests By The Immunochemical Method. Reagents And Working Solutions: ▪ Pc Tm1: 2 Vials, Each For 3.0 Ml Control Serum (Human) ▪ Pc Tm2: 2 Vials, Each For 3.0 Ml Control Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Cortisol Ii (Cortisol) For 100 Tests. Purpose: Intended For Quantitative Determination Of Cortisol In Human Serum, Blood Plasma And Saliva. Cortisol Measurement Is Used To Diagnose And Treat Functionally Impaired Adrenal Glands. Reagents And Working Solutions: The Package With The Main Reagents Is Marked As Cort Ii. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Cortisol Antibodies ~ Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Cortisol Antibodies (Sheep) 20 Ng/Ml; Danazol 20 Μg/Ml; Mesb)-Buffer 100 Mmol/L, Ph 6.0; Preservative R2 Cortisol-Peptide~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Cortisol Derivative (Synthetic), Labeled With A Ruthenium Complex 20 Ng/Ml; Danazol 20 Μg/Ml; Mes-Buffer 100 Mmol/L, Ph 6.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 1.5‑1750 Nmol/L Or 0.054‑63.4 Μg/Dl (Determined By The Value Of The Detection Limit And The Maximum Value Of The Master Calibration). Values Below The Detection Limit Are Displayed As < 1.5 Nmol/L (< 0.054 Μg/Dl). Values Above The Measurement Range Are Displayed As > 1750 Nmol/L (> 63.4 Μg/Dl) (Or Up To 17500 Nmol/L Or 634 Μg/Dl For 10-Fold Dilution Samples). Test Reproducibility - No More Than 1.8%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Luteinizing Hormone (Lh Cs) Calibrator. The Lh Calset Ii Calibration Kit Is Intended For Calibrating The Elecsys Lh Quantitative Analyzer. Reagents And Working Solutions: Lh Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Lh Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Lh (Human) In Two Concentration Ranges (Approximately 1 Miu/Ml And Approximately 45 Miu/Ml ) In The Matrix Of Human Blood Serum. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Insulin (Insulin) For 100 Tests. Purpose: Intended For Quantitative Determination Of Insulin In Serum And Plasma Of Human Blood. Determination Of Insulin Is Used In The Diagnosis And Treatment Of Various Disorders Of Carbohydrate Metabolism, Including Diabetes And Hypoglycemia. Reagents And Working Solutions: The Insulin Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Insulin-Antibody~Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Insulin Antibodies (Mouse) 1 Mg/L; Mesb) Buffer 50 Mmol/L, Ph 6.0; Preservative R2 Anti-Insulin-Antibodies~Ru(Bpy) (Black Cap), 1 Vial, 10 Ml: Monoclonal Anti-Insulin Antibodies (Mouse), Labeled With A Ruthenium Complex 1.75 Mg/L; Mes Buffer 50 Mmol/L, Ph 6.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 84 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.2‑1000 Μu/Ml Or 1.39‑6945 Pmol/L (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Master Calibration). Values Below The Lower Limit Of Detection Are Displayed As < 0.2 Μu/Ml (< 1.39 Pmol/L). The Values Are Above The Measurement Range Is Displayed As > 1000 Μu/Ml (> 6945 Pmol/L). Test Reproducibility - No More Than 1.9%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., The Troponin I Stat Calset Calibration Kit Is Intended For Calibrating The Elecsys Troponin I Stat Quantitative Assay. Reagents And Working Solutions: ▪ Tn-I Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Tn-I Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Troponin I (Recombinant Human) In Two Concentration Ranges (Approximately 0.4 Μg/ L Or Ng/Ml And Approximately 30 Μg/L Or Ng/Ml) In A Human Serum Matrix. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Set Of Precicontrol Thyroab Control Materials Is Used To Control The Quality Of Elecsys Anti-Tshr, Anti-Tpo And Anti-Tg Immunoassays On Elecsys And Cobas E Immunochemical Analyzers. Precicontrol Thyroab Is A Lyophilized Control Blood Serum Based On A Blood Serum Matrix Human In Two Concentration Ranges. Control Materials Are Used To Monitor The Accuracy And Precision Of Elecsys Anti-Tshr, Anti-Tpo And Anti-Tg Immunoassays. Reagents Are Working Solutions ▪ Pc Thyro1: 2 Vials, For Preparation Of 2.0 Ml Of Control Serum Each, ▪ Pc Thyro2: 2 Vials, For Preparation Of 2.0 Ml Of Control Serum Each. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods, The Term Of Replacement Of Low-Quality And Non-Compliant Goods: Within 3 Working Days. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Precicontrol Anti-Hcv Kit Is Intended For Quality Control Of The Anti-Hcv Ii Immunoassay. Reagents And Working Solutions: ▪ Pc A-Hcv1: 8 Vials, Each Containing 1.3 Ml Of Control Serum Human Serum Negative For Anti-Hcv; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Precicontrol Hsv Is Intended For Quality Control Of Elecsys Hsv‑1 Igg And Elecsys Hsv‑2 Igg Immunological Tests. Reagents And Working Solutions: ▪ Pc Hsv1: 2 Vials, Each For 3.0 Ml Of Control Serum Human Serum Negative For Hsv-1 Igg And Hsv-2 Igg Antibodies; Preservative Target Values For The Discriminant Level Index: Hsv‑1 Igg: Approximately 0.30 Coi Hsv‑2 Igg: Approximately 0.30 Coi ▪ Pc Hsv2: 2 Vials, Each For 3.0 Ml Control Serum Human Serum Positive For Hsv‑1 Igg And Hsv‑2 Igg Antibodies; Preservative Target Values For The Discrimination Level Index: Hsv‑1 Igg: Approximately 4.00 Coi Hsv‑2 Igg: Approximately 8.00 Coi. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Procalcitonin (Pct Brahms) For 100 Tests. (According To The Technical Specification), Cassette Prostate-Specific Antigen Free (Free Psa) For 100 Tests. Purpose: In Vitro Immunoassay For Quantitative Determination Of Free Prostate-Specific Antigen In Human Serum And Plasma. Reagents And Working Solutions: The Fpsa Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Psa Antibodies~Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Psa Antibodies (Mouse) 2 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative R2 Anti-Psa Antibodies~Ru(Bpy) (Black Cap), 1 Vial, 9 Ml: Monoclonal Anti-Psa Antibodies (Mouse), Labeled With A Ruthenium Complex 1.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 6 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.01-50 Ng/Ml (Determined By The Measurement Limit Of The Blank Sample And The Maximum Value Of The Master Calibration). Values Below The Detection Limit Are Displayed As < 0.01 Ng/Ml. Values Above The Measurement Range Are Displayed As >50 Ng/Ml. Test Reproducibility - No More Than 1.5%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Cassette C-Peptide (C-Peptide) For 100 Tests. Purpose: Immunoassay For In Vitro Diagnostics. It Is Intended For The Quantitative Determination Of C-Peptide In Human Urine, Serum, And Blood Plasma. This Test Is Intended For Diagnosis And Treatment Of Patients With Impaired Insulin Secretion. Reagents And Working Solutions: The Cpeptid Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-C-Peptide-Antibodies~Biotin (Gray Cap), 1 Vial, 9 Ml: Biotinylated Monoclonal Anti-C-Peptide Antibodies (Mouse) 1 Mg/L; Phosphate Buffer 50 Mmol/L, Ph 6.0; Preservative R2 Anti-C-Peptide-Antibodies~Ru(Bpy) (Black Cap), 1 Vial, 9 Ml: Monoclonal Anti-C-Peptide Antibodies (Mouse), Labeled With A Ruthenium Complex 0.4 Mg/L; Phosphate Buffer 50 Mmol/L, Ph 6.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 4 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 11.00-2000 Pg/Ml Or 0.220-440 Pmol/L (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Aster Calibration). Values Below The Lower Limit Of Detection Are Displayed As < 1.00 Pg/Ml Or < 0.220 Pmol/L. Values Above The Measurement Range Are Displayed As > 2000 Pg/Ml Or > 440 Pmol/L Test Reproducibility - No More Than 1.3%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Luteinizing Hormone (Lh) Cassette For 100 Tests. Purpose: Intended For Quantitative Determination Of Luteinizing Hormone In Serum And Plasma Of Human Blood. Reagents And Working Solutions: The Lh Label Is Pasted On The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Lh Antibodies~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Monoclonal Anti-Lh Antibodies (Mouse) 2.0 Mg/L; Tris Buffer 50 Mmol/L, Ph 8.0; Preservative R2 Anti-Lh Antibodies~Ru(Bpy) (Black Cap), 1 Vial, 10 Ml: Monoclonal Anti-Lh Antibodies (Mouse), Labeled With A Ruthenium Complex, 0.3 Mg/L; Tris Buffer 50 Mmol/L, Ph 8.0; Preservative Storage Conditions: Unopened At 2‑8 °C Until The End Of The Shelf Life. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Prolactin (Prolactin) For 100 Tests. Purpose: Intended For Quantitative Determination Of Prolactin In Serum And Plasma Of Human Blood. Reagents And Working Solutions: The Package With The Main Reagents Is Labeled Prl Ii. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Prolactin-Antibodies~Biotin (Gray Cork), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Prolactin-Antibodies (Mouse) 0.7 Mg/L; Phosphate Buffer 50 Mmol/L, Ph 7.0; Preservative R2 Anti-Prolactin-Antibodies~Ru(Bpy) (Black Cap), 1 Vial, 10 Ml: Monoclonal Anti-Prolactin Antibodies (Mouse), Labeled With A Ruthenium Complex 0.35 Mg/L; Phosphate Buffer 50 Mmol/L, Ph 7.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 1.00-10000 Μiu/Ml Or 0.0470-470 Ng/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Master Calibration). Values Below The Lower Detection Limit Displayed As < 1 Μiu/Ml Or < 0.0470 Ng/Ml. Values Above The Measurement Range Are Displayed As > 10,000 Μiu/Ml Or > 470 Ng/Ml (Or Up To 100,000 Μiu/Ml Or 4,700 Ng/Ml For 10-Fold Dilution Samples). Test Reproducibility - No More Than 1.9%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., The Prolactin Ii Calset Calibration Set Is Intended For Calibrating The Elecsys Prolactin Ii Quantitative Assay. Reagents And Working Solutions: ▪ Prl Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Prl Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Prolactin (Recombinant, Human, From E. Coli) In Two Concentration Ranges (Approximately 2 Μiu /Ml Or 0.09 Ng/Ml And Approximately 2000 Μiu/Ml Or 94 Ng/Ml) In A Buffered Horse Serum Matrix. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Alpha Fetoprotein (Afp) Cassette For 100 Tests. Purpose: Immunoassay For In Vitro Diagnostics. Intended For Quantitative Determination Of Α1-Fetoprotein In Serum And Plasma Of Human Blood. Reagents And Working Solutions: The Package With The Main Reagents Has An Afp Label. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Afp Antibodies~Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Afp Antibodies (Mouse) 4.5 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.0; Preservative R2 Anti-Afp Antibodies~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Anti-Afp Antibodies (Mouse), Labeled With A Ruthenium Complex 12.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.500-1000 Iu/Ml Or 0.605-1210 Ng/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Master Calibration). Values Below The Detection Limit Are Displayed As < 0.500 Iu/Ml Or < 0.605 Ng/Ml. Values Above The Measurement Range Are Displayed As > 1000 Iu/Ml Or > 1210 Ng/Ml (Or Up To 50000 Iu/Ml Or 60500 Ng/Ml For 50-Fold Dilution Samples). Test Reproducibility - No More Than 1.5%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Cassette Tacrolimus Immunotest For The Quantitative Determination Of Tacrolimus (Tacrolimus) For 100 Tests. Purpose: Immunoassay For In Vitro Diagnostics. Intended For The Quantitative Determination Of Tacrolimus In Human Whole Blood. The Test Is Used As An Auxiliary Means Of Correcting The Condition Of A Heart, Liver, And Kidney Transplant In Patients Receiving Tacrolimus Treatment. Reagents And Working Solutions: The Tcl Label Is Pasted On The Package With The Main Reagents. Microparticles Coated With Streptavidin (Transparent Cap), 1 Bottle, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti‑Tacrolimus‑S‑Antibody~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Monoclonal Anti-Tacrolimus Antibody (Sheep) 15 Μg/L; Phosphate Buffer 100 Mmol/L, Ph 7.8; Preservative R2 Tacrolimus~Ru(Bpy) (Black Cap), 1 Bottle, 8 Ml: Tacrolimus Derivative, Labeled With A Ruthenium Complex 4 Μg/L; Citrate Buffer 10 Mmol/L, Ph 3.3; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 12 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.5‑40 Ng/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Reference Calibration Curve). Values Below The Detection Limit Are Defined As < 0.5 Ng/Ml. Values Above The Measurement Range Are Defined As > 40 Ng/Ml. Test Reproducibility - No More Than 2%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., The Precicontrol Cmv Igm Control Sera Set Is Intended For Quality Control Of The Elecsys Cmv Igm Test. Reagents And Working Solutions: ▪ Pc Cmvigm1: 8 Bottles, Each Containing 1.0 Ml Of Control Serum Human Blood Serum, Negative For Cmv Igm Antibodies; Preservative ▪ Pc Cmvigm2: 8 Vials, Each Containing 1.0 Ml Of Control Serum Human Blood Serum Positive For Cmv Igm Antibodies; Hepes Buffer, Ph 7.4; Bovine Serum Albumin; Preservative. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Vitamin D Total Elecsys 100 Tests. It Is Intended For The Quantitative Determination Of Total 25-Hydroxyvitamin D In Human Serum And Plasma. This Test Can Also Be Used To Assess The Sufficiency Of Vitamin D In The Body. The Vitd‑T Label Is Affixed To The Package With The Main Reagents (M, R1, R2) And Reagents For Pretreatment (Pt1, Pt2). Pt1 Reagent 1 For Pretreatment (White Cap), 1 Vial, 4 Ml: Dithiothreitol 1 G/L, Ph 5.5. Pt2 Pretreatment Reagent 2 (Gray Cap), 1 Vial, 4 Ml: Sodium Hydroxide 55 G/L. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Vitamin-D-Binding Protein-Bpru (Gray Cap), 1 Vial, 9 Ml: Ruthenium-Labeled Vitamin-D-Binding Protein (150 Μg/L); Bis-Tris Propane Buffer 200 Mmol/L; Albumin (Human) 25 G/L; Ph 7.5; Preservative R2 25-Hydroxyvitamin D~Biotin (Black Cap), 1 Bottle, 8.5 Ml: Biotinylated Vitamin D (25-Oh) (14 Μg/L); Bis-Tris Propane Buffer 200 Mmol/L; Ph 8.6; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 4 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 3.00-70.0 Ng/Ml Or 7.50-175 Nmol/L (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Reference Calibration Curve). Values Below The Detection Limit Are Defined As < 3.00 Ng/Ml (< 7.50 Nmol/L). Values Above The Measurement Range Are Defined As > 70.0 Ng/Ml (> 175 Nmol/L). Test Reproducibility - No More Than 1.7%., Purpose: Reagent For Pretreatment Of Cyclosporine Samples Cobas Integra Is An In Vitro Diagnostic Reagent Intended For Use With Cobas Integra Reagents And Working Solutions: Copper Sulfate, Methanol (27% By Weight), Ethylene Glycol (38% W/W), Tris Buffer, Sodium Azide (<0.05% W/W), Streptomycin (<0.005% W/W) And Surfactant. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Shelf Life At 2‑8 °C See The Shelf Life On The Label Of The Cobas E Set. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Precicontrol Vitamin D Total Set (A Set Of Control Serums) Is Used To Control The Quality Of Tests Elecsys Vitamin D Total Ii On Elecsys And Cobas E Immunochemical Analyzers. Precicontrol Vitamin D Total Ii Kit Contains Lyophilized Control Serum Based On Human Blood Serum In Two Concentration Ranges. Control Solutions Are Used To Monitor The Accuracy Of The Elecsys Vitamin D Total Ii Immunoassay. Reagents - Working Solutions: ▪ Pc Vitdt1: 3 Fl. 1.0 Ml Of Control Serum Each Human Blood Serum; Preservative Target Value Is Approximately 13 Ng/Ml (32.5 Nmol/L) ▪ Pc Vitdt2: 3 Fl. 1.0 Ml Of Control Serum Of Human Blood Serum; Preservative The Target Value Is Approximately 30 Ng/Ml (75 Nmol/L). Contents Of The Set: ▪ Precicontrol Vitamin D Total Ii Set, 2 Cards With A Bar Code, Sheet Of Paper Control Bar Codes, 2 X 3 Empty Bottles With Closable Lids, Labels For 2 X 6 Bottles. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Troponin I Stat (Troponin I Stat) For 100 Tests. Purpose: Immunoassay For In Vitro Diagnostics For Quantitative Determination Of Troponin I In Serum And Plasma Of Human Blood. This Test Is Intended To Facilitate The Timely Diagnosis And Treatment Of Myocardial Infarctions And Damaged Cardiac Muscles. Reagents And Working Solutions: The Tnistat Label Is Affixed To The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Biotin-Labeled Antibodies To Cardiac Troponin I (Gray Cover); 1 Vial, 10 Ml: 2 Biotinylated Monoclonal Anti-Ctni Antibodies (Mouse) 0.8 Mg/L Each; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative; Inhibitors. R2 Anti-Ctni Antibodies~Ru(Bpy) (Black Cap), 1 Vial, 10 Ml: 2 Monoclonal Anti-Ctni Antibodies (Mouse), Labeled With A Ruthenium Complex 0.8 Mg/L And 0.005 Mg/L, Respectively; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative; Inhibitors. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 14 Days When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.16‑25 Μg/L Or Ng/Ml (Determined By The Value Of The Detection Limit And The Maximum Value Of The Master Calibration). Values Below The Measurement Limit Of The Blank Sample Are Displayed As < 0.1 Μg/L Or Ng/Ml. The Device Does Not Attach A Flag To Values Above The Measurement Limit Of The Blank Sample, But Below The Detection Limit. Values Above The Measurement Range Are Displayed As > 25 Μg/L Or Ng/Ml (Or Up To 250 Μg/L Or Ng/Ml For 10-Fold Dilution Samples). Test Reproducibility - No More Than 2.2%., Cassette Tumor Antigen 19-9 (Ca 19-9) For Cobas E, Elecsys Analyzers For 100 Tests. Purpose: Intended For Quantitative Determination Of Ca 19‑9 In Serum And Plasma Of Human Blood. Reagents And Working Solutions: The Label Ca19‑9 Is Affixed To The Package With The Main Reagents. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Ca 19-9-Ab~Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Anti-Ca 19-9 Antibodies (Mouse) 3 Mg/L, Phosphate Buffer 100 Mmol/L, Ph 6.5; Preservative R2 Anti-Ca 19-9-Ab~Ru(Bpy) (Black Cap), 1 Vial, 10 Ml: Monoclonal Anti-Ca 19-9 Antibodies (Mouse), Labeled With A Ruthenium Complex 4 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.5; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.600‑1000 U/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Master Calibration). Values Below The Detection Limit Are Displayed As < 0.600 U/Ml. Values Above The Measurement Range Are Displayed As > 1000 U/Ml (Or Up To 10000 U/Ml For Samples With 10-Fold Dilution). Test Reproducibility - No More Than 1.9%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., The Vitamin B12 Ii Calset Is Used To Calibrate The Elecsys Vitamin B12 Ii Quantitative Assay. Reagents And Working Solutions: ▪ B12 Ii Cal1: 2 Vials, Each 1.0 Ml Of Calibrator 1 ▪ B12 Ii Cal2: 2 Vials, Each 1.0 Ml Of Calibrator 2 Vitamin B12 In Two Concentration Ranges (Approximately 185 Pmol/L Or 250 Pg/Ml And Approximately 1107 Pmol/L Or 1500 Pg/Ml) In The Matrix Of Human Blood Serum, Preservative. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Cassette Adrenocorticotropic Hormone (Adrenocorticotropic Hormone, Corticotropin–Acth) For 100 Tests. Purpose: Immunoassay For In Vitro Quantitative Determination Of Adrenocorticotropic Hormone (Acth) In Human Edta Plasma. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Acth-Ab~Biotin (Gray Cap), 1 Vial, 8 Ml: Biotinylated Monoclonal Anti-Acth Antibodies (Mouse) 0.3 Mg/L; Mesb) Buffer 50 Mmol/L, Ph 6.2; Preservative R2 Anti-Acth-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 8 Ml: Monoclonal Anti-Acth Antibodies (Mouse), Labeled With A Ruthenium Complex 0.3 Mg/L; Mes Buffer 50 Mmol/L, Ph 6.2; Preservative. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 4 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 1.00-2000 Pg/Ml Or 0.220-440 Pmol/L (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Master Calibration). Values Below The Lower Limit Of Detection Are Displayed As < 1.00 Pg/Ml Or < 0.220 Pmol/L. Values Above The Measurement Range Are Displayed As > 2000 Pg/Ml Or > 440 Pmol/L. Test Reproducibility - No More Than 1.3%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification., Cassette Immunoglobulin G To Cytomegalovirus (Cmv Igg) For 100 Tests. Purpose: Intended For The Quantitative Determination Of Antibodies Of The Igg Class To Cytomegalovirus In The Serum And Plasma Of Human Blood. Reagents And Working Solutions: The Package With Basic Reagents (M, R1, R2) Is Marked As Cmvigg.M Microparticles Coated With Streptavidin (Transparent Cap), 1 Bottle . L, Mes-Buffer 50 Mmol/L, Ph 6.5; Preservative.R2 Cmv‑Ag~Ru(Bpy) (Black Cap), 1 Vial, 9 Ml: Cmv‑Specific Antigen (Recombinant, E. Coli), With A Ruthenium Mesium Complex > 400 Μg/L, Mes Buffer 50 Mmol/L, Ph6.5; Preservative.Cmvigg Cal1 Negative Calibrator 1 (White Cover), 2 Vials Of 1.0 Ml Each: Human Serum, Non-Reactive For Anti-Cmv Igg; Buffer; Preservative Cmvigg Cal2 Positive Calibrator 2 (Black Cap), 2 Bottles Of 1.0 Ml Each: Human Blood Serum, Reactive For Anti‑Cmv Igg; Approx. 40 U/Ml; Buffer; Preservative Storage And Transportation Conditions: Expiration Date At 2‑8°C See Expiration Date On The Label Of The Cobas C Kit. 8 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.25‑500 U/Ml (Determined By The Value Of The Detection Limit And The Maximum Value Of The Master Calibration). Values Below The Measurement Limit Of The Blank Sample Are Displayed As < 0.15 U/Ml. The Device Does Not Flag Values Higher Than The Measurement Limit Of The Blank Sample, But Lower Than The Detection Limit. Values Above The Measurement Range Are Displayed As > 500 U/Ml (Or Up To 10,000 U/Ml For 20-Fold Dilution Samples)., Cassette Prostate-Specific Antigen Total (Total Psa) For 100 Tests. Purpose: In Vitro Test For Quantitative Determination Of The Concentration Of Total (Free + Bound) Prostate-Specific Antigen (Obpsa) In Human Serum Or Plasma. Reagents And Working Solutions: Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles , Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Psa-Ab~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Monoclonal Anti-Psa Antibodies (Mouse) 1.5 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.0; Preservative R2 Anti-Psa-Ab~Ru(Bpy) (Black Cap), 1 Vial, 10 Ml: Monoclonal Anti-Psa Antibodies (Mouse), Labeled With A Ruthenium Complex 1.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.0; Preservative Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. 4 Weeks When Used Onboard The Analyzer At 10-15°C. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. The Measurement Range Is 0.002-100 Ng/Ml (Analyzer Cobas E 411) Or 0.003-100 Ng/Ml (Analyzers Modular Analytics E170, Cobas E 601 And Cobas E 602) (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Reference Calibration Curve). Values Below The Detection Limit Are Defined As < 0.002 Ng/Ml Or < 0.003 Ng/Ml. Values Above The Measurement Range Are Defined As > 100 Ng/Ml (Or Up To 5000 Ng/Ml For Samples With A 50-Fold Dilution). Test Reproducibility - No More Than 1.5%. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%., Folic Acid Cassette (Folate) For 100 Tests. Purpose: Intended For Quantitative Determination Of Folic Acid Salts In Human Serum And Plasma. Reagents And Working Solutions: The Package With The Main Reagents (M, R1, R2) And Reagents For Preliminary Processing (Pt1, Pt2) Has A Fol Iii Label. Pt1 Pretreatment Reagent 1 (White Cap), 1 Vial, 4 Ml: 2-Mercaptoethanesulfonic Acid (Mesna) 40 G/L, Ph 5.5. Pt2 Pretreatment Reagent 2 (Gray Cap), 1 Vial, 5 Ml: Sodium Hydroxide 25 G/L. M Microparticles Coated With Streptavidin (Transparent Cap), 1 Vial, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Folate-Binding Protein~Ru(Bpy) (Gray Cap), 1 Vial, 9 Ml: Ruthenium-Labeled Folate-Binding Protein 75 Μg/L; Human Serum Albumin (Stabilizer); Borate/Phosphate/Citrate Buffer 70 Mmol/L, Ph 5.5; Preservative R2 Folate~Biotin (Black Cap), 1 Bottle, 8 Ml: Biotinylated Salts Of Folic Acid 17 Μg/L; Biotin 120 Μg/L; Human Serum Albumin (Stabilizer); Borate Buffer 100 Mmol/L, Ph 9.0; Preservative Storage Conditions: Unopened At 2‑8 °C Until The End Of The Shelf Life. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Triiodothyronine Free Calibrator (Ft3 Cs). The Ft3 Iii Calset Calibration Set Is Intended For Calibrating The Elecsys Ft3 Iii Quantitative Analyzer. Reagents And Working Solutions: ▪ Ft3 Iii Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Ft3 Iii Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Ft3 In Two Concentration Ranges (Approximately 2 Pmol/L Or 1.3 Pg/Ml And Approximately 40 Pmol/L Or 26 Pg/Ml) In The Human Serum Matrix. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., The Cortisol Ii Calset Calibration Set Is Intended For Calibration Of The Cortisol Ii Quantitative Assay. Reagents And Working Solutions: Cort Ii Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Cort Ii Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 Cortisol (Synthetic) In Two Concentration Ranges (Approximately 12.5 Nmol/L Or 0.45 Μg/ Dl And Approximately 1000 Nmol/L Or 36 Μg/Dl) In A Human Serum Matrix. Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Free Thyroxine Calibrator (Ft4 Cs). The Ft4 Ii Calset Calibration Set Is Intended For Calibrating The Elecsys Ft4 Ii Quantitative Analyzer. Reagents And Working Solutions: Ft4 Ii Cal1: 2 Vials, Each With 1.0 Ml Of Calibrator 1 ▪ Ft4 Ii Cal2: 2 Vials, Each With 1.0 Ml Of Calibrator 2 L-Thyroxine In Two Concentration Ranges (Approximately 10 Pmol/L Or 0.78 Ng/Dl And Approximately 45 Pmol/L Or 3.5 Ng/Dl) In Buffer/Protein Matrix (Bovine Serum Albumin). Storage And Transportation Conditions: Store In A Refrigerator In A Strictly Vertical Position. Expiry Date At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15 °C Single Use, When Frozen For 1 Month. Transportation Must Be In Thermal Containers With Cooling Elements At A Temperature Of 2-8 °C In A Strictly Vertical Position, Do Not Expose To Freezing Or Exposure To High Temperatures. The Calibration Is Linear At Two Points, The Frequency Of Calibration Is 7 Days. Reagents For The Cobas E601 Analyzer. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. The Scope Of Delivery Is For Eu Countries. The Final Shelf Life Is Not Less Than 60%. If The Product Does Not Meet The Technical Specification, The Product Will Be Replaced Within 3 Days After Notification. The Presence Of A Document Confirming The Supply By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer.
Key Value
Tender Value
12,243,777 - KZT
Tender Documents
Global Tender Document
d474d63f-4ec9-48ad-8e34-c26a038ad9db.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.