GTR 80918720
Tenders Are Invited For Reconstruction Of The Outbuilding Into A Veterinary Building - Stage I
ICB — International Competitive Bid
Closed
central europe
Tender Information
GTR Reference
80918720
Tendering Authority
Subscribe to view
Tender No
ZSCKR.271.10.2024
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Reconstruction Of The Outbuilding Into A Veterinary Building - Stage I
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
central europe
Political Region
European Union
Last Date of Bid Submission
14-06-2024
Closed
Work Detail
1. The Subject Of The Order Are Construction Works Related To The Superstructure And Reconstruction Of The Existing Teaching Building Of The School Annex On The Premises Of The School Complex Of The Agricultural Education Center. Ziemia Dobrzyńska In Nadroże On The Plot With Registration Number 172 In Order To Adapt The Building To Conduct Classes In The Field Of Veterinary Technology.2. Construction Works As Part Of The Planned Investment Will Include, Among Others: 1) Performing The Necessary Drainage Of The Foundations And Membranes To Protect Against Moisture, 2) Strengthening/Repairing/Replacing The Ceilings Above The Basement Along With Finishing Layers, 3) Installing A New Floor On The Ground In The Basement, 4) Underpinning The Walls Of The Rooms In Order To Obtain The Correct Usable Height, 5) Constructing A Ceiling Above The Ground Floor And A New Roof Structure With Covering Layers, 6) Changing The Layout Of The Rooms And Their Functions (Constructing New Partition Walls), 7) Changing The Dimensions Of Windows And Internal And External Doors,8) Construction Of New Entrance Stairs Leading To The Ground Floor Of The Building And The Basement,9) Construction Of A Lighting Installation And 230V Sockets,10) Construction Of A Lightning Protection System,11) Construction And Installation Of A Heat Pump.3. Attention! The Order Does Not Include: 1) In The Scope Of Construction Works Related To The Facade: A) Execution Of External Layers Of Walls Included In Detail S2 In The Description And In Drawing No. A3, Za-3, I.E. Thin-Layer Plaster, 2X Glue With A Fiberglass Mesh Of Min. . 160 G/M2, Styrofoam 15 Cm Included In The Technical Design And The Design Including Insignificant Changes, B) Execution Of External Layers Of Walls, Detail S3 In The Description And In Drawing No. A3, Za-3, I.E. Thin-Layer Plaster, 2X Glue With A Mesh With Glass Fiber By A Gram Min. 160 G/M2, 20 Cm Polystyrene Included In The Technical Design And The Design Including Insignificant Changes, C) Construction Of External Window Sills From Powder-Coated Galvanized Sheet Metal In The Description And In Drawing No. A4, Z-A4, A5, Z-A5 Included In The Design Technical And Design Including Insignificant Changes.2) In The Scope Of Construction Works Regarding Door Joinery: A) Construction Of Single-Leaf Internal Fire-Resistant Aluminum Doors. Ei30 Dw4 Included In Drawing No. A1, Za-1, A9, Za-9 Included In The Technical Design And The Design Including Insignificant Changes, B) Versions Of Full Single-Leaf Internal Panel Doors, Factory-Finished Dw1, Dw2, Dw3 Included In Drawings No. A9, Za-9, A2, A7 Included In The Technical Design And The Design Including Insignificant Changes.3) In The Scope Of Construction Works Regarding Internal Finishing Works: A) Finishing Of Walls And Ceilings Described In Point 5 Entitled Construction And Material Solutions For Internal And External Building Partitions Of The Technical Design And The P2 Indicated In The Detail, I.E. 2X G-K Boards And S2 And S3, I.E. Cement-Lime Plaster. 2 Cm Included In Drawings A3, Za-3 In The Technical Design And The Design Including Insignificant Changes, B) Finishing Of Floors Described In Point 5 Entitled Construction And Material Solutions Of Internal And External Building Partitions Of The Technical Design And Those Indicated In Detail P1 And P1, I.E. Floor Finishing Layers And Detail P0 - All Layers Included In Drawings A3 And Za3, A1, Za-1, A2 In The Technical Design And The Project Including Insignificant Changes, C) Equipment For Disabled People Distinguished In Room 1.02. In The Description And In Drawings A2, A7, A11 Included In The Technical Design And In The Design Including Insignificant Changes, D) Classroom Equipment Included In Its Entirety In The Description And In Drawing A11 Included In The Technical Design, 4) In The Scope Of Construction Works Related To Hardening The Area Along With With A Parking Space: A) Construction Of Curbs And Concrete Edges As Well As Surfaces Made Of Concrete Paving Stones Constituting Communication Routes And A Parking Space, Included In The Description And Drawings Z-T1, Z-T3.5) In The Scope Of Construction Works Regarding The Electrical Installation: A) Execution Photovoltaic Installation Described In Point 4.13. Technical Description And Drawing E5 Of The Technical Design For Electrical Installations.4. Described Above. Works Are Excluded From The Procedure, Even If They Are Included In Documents Other Than Those Described Above And The Exclusion Is Not Expressly Indicated In The Technical Documentation.5. A Detailed Description Of The Subject Of The Order Is Attached As Appendix No. 1 To The Swz - Design Documentation. 6. The Attached Bills Of Quantities Are Only Intended To Assist In Preparing The Offer.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
2c96214f-c658-4b50-9958-8755a1a6ada2.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.