GTR 80630377
Tenders Are Invited For Construction Of A Sanitary Sewage System. Pressure Street Szkolna And Ul. Wiejska In Psary And Ul. Wiejska In Sarnów As Part Of The Task: Construction Of A Sewage Network For The Needs Of Sim In The Psary Commune - Stage Iv - (...).
ICB — International Competitive Bid
Closed
Central Europe
Tender Information
GTR Reference
80630377
Tendering Authority
Subscribe to view
Tender No
ZP.271.08.2024
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Construction Of A Sanitary Sewage System. Pressure Street Szkolna And Ul. Wiejska In Psary And Ul. Wiejska In Sarnów As Part Of The Task: Construction Of A Sewage Network For The Needs Of Sim In The Psary Commune - Stage Iv - (...).
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
06-06-2024
Closed
Work Detail
1. Subject Of The Order. The Subject Of The Order Is An Investment In The Field Of Sewage Management, Including The Construction Of The Main Sections Of The Sanitary Pressure Sewage Network Between Nodes F1 To F449 (In Accordance With Drawings E2c_Pz-2.1, E2c_Pz-2.4, E2c_Pz-2.5, E2c_Pz-2.6) And Connections From Above Pressure Sanitary Sewage System To The Boundaries Of Private Properties Along The Road In Psary At Ul. Szkolna And Ul. Wiejska And In Sarnów At Ul. Wiejska.2. Pressure Sanitary Sewage System:2.1. From Junction F1 To F135 - Pe Rc Sdr11 Dn140 Pipe, Approx. 961.88 M Long; 2.2. From The F135 To F248 Junction - Pe Rc Sdr11 Dn140 Pipe, Approx. 787.96 M Long; 2.3. From Junction F248 To F335 - Pe Rc Sdr11 Dn140 Pipe, Approx. 647.41 M Long; 2.4. From Junction F335 To F353 - Pe Rc Sdr11 Dn110 Pipe, Approx. 121.02 M Long; 2.5. From Junction F353 To F422 - Pe Rc Sdr11 Dn110 Pipe, Approx. 487.28 M Long; 2.6. From Junction F422 To F449 - Pe Rc Sdr11 Dn110 Pipe, Approx. 253.47 M Long; 2.7. Branch From The F10 Node To The Plot Border - Pe Rc Sdr11 Dn50 Pipe, Approx. 2.36 M Long; 2.8. Branch From The F12 Node To The Plot Border - Pe Rc Pipe Dn50, Approx. 2.23 M Long; 2.9. Branch From The F14 Node To The Plot Border - Pe Rc Pipe Dn50, Approx. 7.06 M Long; 2.10. Branch From The F18 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 5.55 M Long; 2.11. Branch From The F34 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 7.18 M Long; 2.12. Branch From The F43 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 7.00 M Long; 2.13. Branch From The F51 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 7.77 M Long; 2.14. Branch From The F63 Node To The Plot Border - Pe Rc Pipe Dn50, Approx. 2.54 M Long; 2.15. Branch From The F69 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.24 M Long; 2.16. Branch From The F87 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 2.63 M Long; 2.17. Branch From The F92 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 3.62 M Long; 2.18. Branch From The F95 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 7.53 M Long; 2.19. Branch From The F107 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 2.58 M Long; 2.20. Branch From The F117 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 3.20 M Long; 2.21. Branch From The F118 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 6.04 M Long; 2.22. Branch From The F123 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 6.98 M Long; 2.23. Branch From The F145 Junction To The Plot Border - Pe Rc Pipe Dn63, Approx. 11.56 M Long; 2.24. Branch From The F154 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 6.67 M Long; 2.25. Branch From The F160 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 6.88 M Long; 2.26. Branch From The F161 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 3.33 M Long; 2.27. Branch From The F172 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 6.48 M Long; 2.28. Branch From The F179 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 7.25 M Long; 2.29. Branch From The F182 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 5.98 M Long; 2.30. Branch From The F190 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.36 M Long; 2.31. Branch From The F193 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.83 M Long; 2.32. Branch From The F198 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 10.25 M Long; 2.33. Branch From The F211 Junction To The Plot Border - Pe Rc Pipe Dn63, Approx. 3.56 M Long; 2.34. Branch From The F226 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 7.95 M Long; 2.35. Branch From The F234 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 7.85 M Long; 2.36. Branch From The F235 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 2.83 M Long; 2.37. Branch From The F252 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 1.67 M Long; 2.38. Branch From The F263 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 1.85 M Long; 2.39. Branch From The F276 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 6.00 M Long; 2.40. Branch From The F297 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.00 M Long; 2.41. Branch From The F304 Node To The Plot Border - Pe Rc Pipe Dn50, Approx. 5.80 M Long; 2.42. Branch From The F306 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 6.90 M Long; 2.43. Branch From The F307 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 3.20 M Long; 2.44 M. Branch From The F309 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 3.50 M Long; 2.45 M. Branch From The F314 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 7.49 M Long; 2.46 M. Branch From The F322 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.46 M Long; 2.47 M. Branch From The F324 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 2.25 M Long; 2.48. Branch From The F325 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.24 M Long; 2.49 M. Branch From The F326 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.15 M Long; 2.50. Branch From The F329 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 2.55 M Long; 2.51. Branch From The F331 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 2.66 M Long; 2.52. Branch From The F347 Junction To The Plot Border - Pe Rc Pipe Dn63, Approx. 8.15 M Long; 2.53. Branch From The F372 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.09 M Long; 2.54. Branch From The F383 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 6.24 M Long; 2.55. Branch From The F390 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.14 M Long, 2.56 M. Branch From The F391 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 4.50 M Long; 2.57. Branch From The F393 Junction To The Plot Border - Pe Rc Pipe Dn63, Approx. 8.36 M Long; 2.58. Branch From The F400 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 4.79 M Long; 2.59 M. Branch From The F420 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 5.72 M Long; 2.60. Branch From The F422 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 3.50 M Long; 2.61. Branch From The F441 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 2.57 M Long; 2.62. Branch From The F430 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 8.01 M Long; 2.63. Branch From The F263 Node To The Plot Border - Pe Rc Pipe Dn50, Approx. 1.85 M Long; 2.64 M. Branch From The F276 Junction To The Plot Border - Pe Rc Pipe Dn50, Approx. 6.00 M Long; 2.65. Branch From The F334 Node To The Plot Border - Pe Rc Pipe Dn90, Approx. 17.23 M Long. Total Pe Rc Sdr11 Pipes For The Sanitary Sewage Network: Dn140 - Approx. 2,397.25 Mdn110 - Approx. 861.77 Mdn90 - Approx. 17.23 Mdn63 - Approx. 32.33 Mdn50 - Approx. 316.76 Mthe Pressure Sanitary Sewage Network Will Be Equipped With Cut-Off Fittings In The Form Of Cast Iron Flanged Knife Gate Valves And Dn100 Vent Valves, Which Will Be Installed In Dn1000 Concrete Wells. Sanitary Sewage Connections To The Borders Private Plots Pe100 Sdr11 Dn40 With A Total Length Of Approx. 1,785.59 M. The Connections Will Be Equipped With Dn32 Cast Iron Flanged Knife Gate Valves, And Their Ends At The Border Of Private Plots Will Be Plugged With Electrofusion Welded Pe Plugs. The Route Of The Pressure Sanitary Sewage Network Was Routed Along A District Road . Its Course Has Been Agreed With The Road Manager. The Planned Sanitary Pressure Sewage System Is Located On Plots No.: 674, 1519, 1518, 1516, 1858, 2125/10, 2542, 2545, 2389/6, Precinct 0008 Psary; Plot No. 861/3, District 0009 Sarnów. The Route Of The Sewage Network In Question Intersects With The Following Underground Utilities: Water Supply, Telecommunications, Energy, Gas And Storm Sewage Networks. The Location Of The Existing Underground Utilities Is Marked On Site Plans And Profiles. However, The Existence Of Other Underground Utilities Not Shown On The Site Plans Cannot Be Ruled Out. The Intersections Of The Designed Networks With Elements Of The Existing Underground Infrastructure Have Been Agreed With The Relevant Entities Managing A Given Network. Domestic Sewage From Residential Buildings Will Be Discharged Through Pe Dn40 Or Pe Dn50 Pressure Pipelines To The Designed Pe Dn50-Dn140 Pressure Collectors. The Task Also Involves Restoring The Road And Shoulder Elements To Their Original Condition In Accordance With The Requirements Of The Road Manager And In Accordance With Construction Practice And Polish Standards. Therefore, The Road Structure Must Be Fully Reconstructed After The Works Performed Using The Excavation Method, As Well As The Reconstruction Of The Road Surface. The Planned Sanitary Pressure Sewage System For Domestic Sewage Will Be Incorporated Into The Pressure Sanitary Sewage System Constructed In Accordance With A Separate Study Construction Of A Pressure Sanitary Sewage System And Reconstruction Water Supply Network In The Psary Commune” – Ul. Kamienna In Psary, In Accordance With The Terms Of Reference Regarding The Implementation Of The Task In Question.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
6631c06f-ddc6-4704-a9f8-a2b92cf82bc5.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.