GTR 80321502

Tenders Are Invited For Modernization Of The Building Of The District Post-Secondary School Complex In Wejherowo

ICB — International Competitive Bid Closed Central Europe
Tender Information
GTR Reference
80321502
Tendering Authority
Subscribe to view
Tender No
Nr postepowania: PZSP.271.1.2024
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Modernization Of The Building Of The District Post-Secondary School Complex In Wejherowo
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
28-05-2024 Closed
Work Detail
1. The Subject Of The Order Is The Modernization Of The Building Of The District Post-Secondary School Complex In Wejherowo.2. Due To The Specific Nature Of The Facilitys Operation, Work May Begin No Earlier Than June 24, 2024, I.E. After The End Of The School Year. Commencement Of Work On The Scheduled Date Will Not Disrupt The Organization Of Work At The School, In Particular It Will Not Disrupt Teaching Activities.3. Due To The Specific Nature Of The Facilitys Operation, All Works Inside The Building Must Be Completed By August 31, 2024, I.E. Before The Start Of The School Year. Other Works: Up To 3 Months From Signing The Contract Scope Of Work: Insulation Of Foundation Walls: - Careful Digging And Storage Of Ornamental Plants Growing At The Front Façade, - Dismantling Hardened Surfaces Made Of Concrete Cubes Together With The Edges To The Extent Necessary To Excavate Basement And Foundation Walls, - Dismantling The Pebble Strip (For Re-Laying), - Dismantling The Concrete Basement Well And The Concrete Surface In Front Of The Entrance To The Building, - Cleaning And Filling The Joints Of Basement And Foundation Walls (Below The Ground), - Execution Of Ordinary Plasters Of Category Ii For Basement And Foundation Walls (Below The Ground), - Execution Of Horizontal Insulation Of Basement And Foundation Walls Using The Crystal Injection Method, - Execution Of 2 X Vertical Insulation Of Basement And Foundation Walls (Below The Ground) Made Of Dispersion Asphalt-Rubber Mass With Priming The Base With Asphalt Emulsion, - Thermal Insulation Of Basement And Foundation Walls (Below The Ground) Made Of Eps 100 Hydro 031 Thick Polystyrene Boards. 8 Cm, - Installation Of Plastic Light Wells With Dimensions 130X60x80 Cm Of Windows Below The Ground, - Disassembly And Reassembly Of The Barrier, - Backfilling Of Excavations In 20 Cm Layers With Mechanical Compaction, - Removal Of Excess Soil, - Supplementing The Surface With Concrete Cubes (From Demolition) On A Base Of Crushed Aggregate. 15 Cm, - Reconstruction Of Pebble Strips With Laying Of Concrete Edges (From Demolition), - Installation Of Galvanized Steel Shoe Mats, Dimensions. 120X60 And 140X50 Cm, - Repair And Supplementation Of The Ring Lightning Protection System Along With Measurements, - Restoration Of Plantings Of Ornamental Plants, - Removal And Disposal Of Rubble. Interior Works: - Disassembly Of Door Frames In The Staircase, - Dismantling Of The Stair Railing, - Dismantling Of Cement Floors Along With Plinths And A Leveling Layer In The Corridors And The Staircase, - Dismantling The Terrazzo Cladding Of The Stairs Together With The Plinths, - Removal And Disposal Of Demolition Materials, - Moisture Insulation Of The Basement Floor With Polyethylene Foil, - Installation Of A Leveling Layer Of Thickness 5 Cm Under The Floors, - Making A Leveling Layer Thick. 2 Cm Under The Stair Steps, - Floors Made Of Anti-Slip Stoneware Tiles, Dimensions. Min. 30X30 Cm With Pedestals, Height 10 Cm, - Staircase Lining Made Of Stoneware Tiles, Dimensions: Min. 30X30 Cm With Plinths 10 Cm High (Grooved Tiles On The Edges Of The Steps), - Installation Of Partition Walls From Gkf Boards Up To Rei 60 (Separation Of The Staircase), - Filling The Recesses With Aerated Concrete Blocks After The Dismantled Hydrants With Additional Plasters, - Embedding The Doors In Glazed And Full Fire-Resistant Alu Profiles Ei30s According To The Design, - Replacement Of External Double-Leaf (Air-Air) Doors With New Ones In Pvc Profiles With Coefficient U = Min. 1.3 W/Mk With Door Closer, Actuator And Reversible Lock, - Installation Of Full Fire-Resistant Steel Doors. Ei30s (Entrance To The Attic), - Installation Of A Smoke Exhaust Window With An Area Of Active Smoke Exhaust 1.10 M2, - Coating Walls And Ceilings, - Installing A Stainless Steel Stair Balustrade According To The Drawing, - Installing Stainless Steel Handrails, - Scraping And Washing Off Old Paint From Walls And Ceilings, - Leaching Oil Paint From Wall Plasters (Removing Paneling), - Painting Walls With Multi-Colored Resin-Acrylic Paint Using The Spraying Method, - Painting Ceilings With Emulsion Paints, - Dismantling And Reassembling Lighting Fixtures And Electrical And Telecommunications Equipment To The Extent Necessary To Perform The Works. Roof Renovation: - Making A Hole In The Roof For A Hatch Smoke Removal Together With Sheet Metal Work, - Cleaning The Roofing Felt From Lichen, - Insulating It Twice With Asphalt Emulsion, - Covering The Roof With Thermally Weldable Surface Felt. Min. 5.2 Mm Staircase Smoke Exhaustment: - Installation Of The Smoke Exhaust System With Installation Of The Control Panel In Accordance With The Design, - Power Supply To The Air Intake Door, - Power Supply To The Smoke Exhaust Flap, - Power Supply To The Priority Valve, - Forging And Grouting Grooves For The Above Ducts, - Disassembly And Reassembly Of Lighting Fixtures And Electrical And Telecommunications Equipment To The Extent Necessary To Perform The Works. Hydrant Installation: - Disassembly Of Existing Hydrants Together With The Water Supply Installation, - Construction Of A New Hydrant Installation In Accordance With The Design, - Installation Of New 25 Mm Hydrants In The Basement, Ground Floor, First Floor , 2Nd Floor And Attic, - Installation Of A Priority Valve And An Anti-Contamination Valve In The Existing Water Supply System In The Basement Room, - Installation Of A Backflow Isolator With A Filter, - Repair And Replenishment Of Plaster And Paint Coatings On The Walls After Dismantling And Installing A New Hydrant Installation.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
6e87d297-3afc-4ee3-92c1-5a7769a512ed.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders