GTR 80131693
Bids Are Invited For Formation Of Price Registration For Future Hiring Of A Company Specialized In The Supply Of Hospital Materials/Equipment For The José Laurentino Bezerril Maternity Hospital.
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
80131693
Tendering Authority
Subscribe to view
Tender No
005/2024
Financer Name
Self-Funded
Work Title
Bids Are Invited For Formation Of Price Registration For Future Hiring Of A Company Specialized In The Supply Of Hospital Materials/Equipment For The José Laurentino Bezerril Maternity Hospital.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
20-05-2024
Closed
Work Detail
Lador Pulmonary Ventilator Adult/Pediatric/Neonatallung Ventilator For Adult, Pediatric And Neonatal Ventilatory Support With 12-Inch Color Lcd Screen, Sensitive To Touch. Micro-Processed, Time Cycled, Volume Or Flow. Must Operate By 02 Network And Hospital Compressed Air Network. The Ventilator Must Have A Self-Test System To Detect Leaks In The Respiratory Circuit As Well As Measure The Compliance And Resistance Of The Circuit For Greater Reading Accuracy; It Has An Internal Battery With Autonomy Of 240 Minutes, An Articulated Arm To Support The Respiratory Circuit, A Pedestal With Casters And Locks And Has Trigger Sensitivity To Flow And Pressure; Have 100% Oxygen Release With Automatic Return For Deaspiration Maneuver. Blender With 02 Internal Electronics, Without Wires Or Apparent Connections, It Should Store The Last Adjusted Parameters In Memory; Have The Following Ventilation Modes; Volume Controlled: Pressure Controlled;Prvc-Pressure Regulated With Controlled Volume; Synchronized Intermittent Mandatory Ventilation At Controlled Volume, Associated With Pressure Support; Synchronized Intermittent Mandatory Ventilation At Controlled Pressure, Associated With Pressure Support; Synchronized Intermittent Mandatory Ventilation Pressure Regulated With Controlled Volume; Psv - Support Pressure; Volume Support; Have Non-Invasive Ventilation Mode With Leak Compensation; High-Flow Oxygenation For Nasal Canula Up To 60 L/Min; Have A Nebulizer, Integrated Into The System Without Variation In The Fio2 Offered; Programmable Respiratory Rate From 1 To 100 Cycles/Min Programmable Respiratory Time From 0.1 To 5.0 Seconds; Programmable Current Volume From 10Ml To 2000Ml; Inspiratory Flow Up To 160L/Min Controlled Inspiratory Pressure Adjustable From 1 To 95Cmh2o; Support Pressure Up To 80 Cmh2o; Peep/Cpap: Up To 50Cmh2o; Oxygen Concentration From 21 To 100% Monitored By Internal Cell Or Permanent Sensor; Trigg, Emergency Car: Color: White Epoxy Painting 4 Castors, 2 With Brakes And 360° Degree Rotation. 03 Drawers: 01 For Medicines And 02 For General Use Locks On Drawers Swinging Door 01 Board For Cardiac Massage Support For Oxygen Cylinder Serum Support Cardioverter Or Defibrillator Support Electrical Socket *Structure: Carriage And Drawers – Made Of Steel Tray – Made Of Steel Locking System Included In The Drawers., Multiparametric Monitormultiparametric Monitor: 10 To 12 Inch Touch Sensitive Screen; Transport Handle; Minimum 05 Parameter Curves And Large Numbers. Capable Of Storing Up To 120 Hours Of Alarm Events, As Well As Graphical And Numerical Trends, With “Full-Disclosure” Review; It Must Have The Possibility Of Future Connection Between At Least 08 Monitors Without The Need For A Central Unit; It Must Include A Menu To Guide Health Professionals In Their Pre- And Post-Hospital Care Routine, In Addition To Providing Assistance Regarding Errors And Queries In All Parameters. Must Have Possibility For Future Use Of Remote Control. Audiovisual Alarms With 3 (Three) Priority Levels. Invasive Pressure: Measurement Range: 1 To 300Mmhg; Must Allow Labeling And Alarm Settings; Capnography: Must Measure Etco2 Using The Mainstream Method; Range From 0 To 150 Mmhg Minimum Respiratory Rate From 3 To 150Rpm; Presentation Of The Capnography Waveform And The Respective Etco2 Values And Breaths/Minutes; Use In Adult, Pediatric And Neonatal Patients; Must Allow Use In Intubated And Non-Intubated Patients
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
b61998d7-43cf-4349-bff7-c972f90013d3.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.