Bids Are Invited For Hiring A Company Specialized In Installation And Preventive And Corrective Maintenance Of Air Conditioning Devices. To Serve The 10 Ubs. This Service Is Justified Given The High Temperatures That Affect Our City, Requiring Greater Demand From Air Conditioning Units To Keep The Units Air-Conditioned. Assisted By Sms. The Quantity Requested Here Is An Estimated Survey And Can Be Carried Out In Smaller Quantities Than What We Present Here.
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
78962904
Tendering Authority
Subscribe to view
Tender No
1829/2024
Financer Name
Self-Funded
Work Title
Bids Are Invited For Hiring A Company Specialized In Installation And Preventive And Corrective Maintenance Of Air Conditioning Devices. To Serve The 10 Ubs. This Service Is Justified Given The High Temperatures That Affect Our City, Requiring Greater Demand From Air Conditioning Units To Keep The Units Air-Conditioned. Assisted By Sms. The Quantity Requested Here Is An Estimated Survey And Can Be Carried Out In Smaller Quantities Than What We Present Here.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
10-04-2024
Closed
Work Detail
Preventative And Corrective Maintenance Of 9,000 Btus, Split Or Inverter Air Conditioning Units – Which Includes At A Minimum The Performance Of The Following Procedures: General Cleaning Of The Equipment; Checking And Maintenance Of Pipe Insulations; Elimination Of Rust Spots; Cleaning Air Filters; Compressor Checking And Maintenance; Internal And External Cleaning Of Evaporators; Internal And External Cleaning Of Condensers; Cleaning The Evaporator Coils; Adjustment Of Thermostats; Air Flow Measurement; Checking And Correcting The Alignment And Fixing Of The Fan And Motor Pulleys; Measuring Amperage And Voltage Of Motors And Fans; Checking The Electrical Panels, Regarding Overheating And Tightening The Terminals, Repairing Irregularities; Mechanical, Electrical And Electronic Maintenance Of Equipment; Maintenance Of Power Circuits And Electrical Control Of Equipment; Maintenance Of All Peripheral Parts And Components; General Lubrication, 9,000 Btus Air Conditioning, Split Or Inverter - Removal Of The Equipment, External Evaporator And Condenser, Pack, Seal The Air Inlet And Outlet Pipes, Evaporator And Condenser, Leave The Copper Pipe Packed In The Condenser., Air 12,000 Split Or Inverter Conditioning - Installation Must Occur In Accordance With The Technical Specifications Of The Air Conditioning Manufacturer, Gas Used, Kg Of Gas. Follow The Specificity Of Each Unit Where The Installation Will Take Place. All Installation Materials, Copper Pipe, Flange, Fixing Screws, Washers, Bracket, Wire, Circuit Breaker And Solder. Installer Is Responsible For All Installation Materials, Preventative And Corrective Maintenance Of 12,000 Btus Split Or Inverter Air Conditioning Unit - Understand At A Minimum The Performance Of The Following Procedures: General Cleaning Of The Equipment; Checking And Maintenance Of Pipe Insulations; Elimination Of Rust Spots; Cleaning Air Filters; Compressor Checking And Maintenance; Internal And External Cleaning Of Evaporators; Internal And External Cleaning Of Condensers; Cleaning The Evaporator Coils; Adjustment Of Thermostats; Air Flow Measurement; Checking And Correcting The Alignment And Fixing Of The Fan And Motor Pulleys; Measuring Amperage And Voltage Of Motors And Fans; Checking The Electrical Panels, Regarding Overheating, And Tightening The Terminals, Repairing Irregularities; Mechanical, Electrical And Electronic Maintenance Of Equipment; Maintenance Of Power Circuits And Electrical Control Of Equipment; Maintenance Of All Peripheral Parts And Components; General Lubrication., Air Conditioning 12.Thousand Btus Split Or Inverter - Recharge Must Follow The Air Conditioning Device Manufacturers Standards, Following Gas Specification, Kg Of Gas Of Each Device., 04/04/2024, Air Conditioning 18,000 A 24,000 Btus, Specialized Technical Check, Replacement Of The Capacitor Recommended By The Manufacturer, Or Contactor Recommended By The Manufacturer., Air Conditioning 18,000 To 24,000 Btus - Recharging Must Follow The Air Conditioning Device Manufacturers Standards, Air Conditioning 37,000 Btus - Recharging Must Follow The Air Conditioner Manufacturers Standards, Air Conditioner 60,000 Btus Specialized Technical Check, Contactor Replacement Recommended By The Manufacturer
Key Value
Tender Value
24,950 - BRL
Tender Documents
Global Tender Document
c5c1d068-965a-47ef-9d38-2d27854bc134.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.