GTR 78770834

Tenders Are Invited For Construction And Assembly Works For The Introduction Of Energy Efficiency Measures In The Atanas Nedelchev Dg, Byala Cherkva, Pavlikeni Municipality

ICB — International Competitive Bid Closed Eastern Europe
Tender Information
GTR Reference
78770834
Tendering Authority
Subscribe to view
Tender No
00039-2024-0007
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Construction And Assembly Works For The Introduction Of Energy Efficiency Measures In The Atanas Nedelchev Dg, Byala Cherkva, Pavlikeni Municipality
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Eastern Europe
Political Region
Balkans,European Union,G20
Last Date of Bid Submission
29-04-2024 Closed
Work Detail
The Subject Of The Public Procurement Is Construction And Assembly Works For The Introduction Of Energy Efficiency Measures In The Atanas Nedelchev Public Works Department, Byala Cherkva, Pavlikeni Municipality, Financed Under The Energy Efficiency In The Atanas Nedelchev Public Works Department Project. Byala Church, Pavlikeni Municipality, Adbfp No. Bg06rdnp001-7.020-0062-C01/26.01.2024, Between Df Agriculture And Pavlikeni Municipality, Submeasure 7.2 Investments In The Creation, Improvement Or Expansion Of All Types Of Small-Scale Infrastructure By Measure - 7 Basic Services And Renewal Of Villages In Rural Areas From The Rdp 2014-2020, Co-Financed By The European Agricultural Fund For Rural Development. Project Solutions For Individual Parts Of The Attached Investment Project Include: • Energy-Saving Measures: An Energy Efficiency Report Has Been Prepared For The Site. The Following Energy-Saving Measures Are Planned. - Thermal Insulation With Eps With Δ= 100 Mm And Coefficient. Of Thermal Conductivity Λ≤0.0315 W/Mk On All Non-Insulated Facade Walls - Thermal Insulation With Xps With Δ= 100 Mm And Coefficient. Of Thermal Conductivity Λ≤0.030 W/Mk Per Plinth - Thermal Insulation Of Window Pages (Turning) With Xps, Δ=2 Cm, With Coef. Of Thermal Conductivity Λ≤0.030 W/Mk - Thermal Insulation Of A Cold Roof With Stone Wool Mattresses, Δ=150 Mm And Coefficient. Of Thermal Conductivity Λ≤0.04 W/Mk. On The Floor Of The Attic Space. - Replacing The Old Wooden Windows With Pvc Windows - Five-Chamber Double-Glazed Windows With Heat Transfer Coefficient Λ ≤1.40 W/M2k - Thermal Insulation Of The Floor Of The First Floor With Xps, Δ=5 Cm Λ ≤0.033 W/Mk Laid On The Ceiling Of The Basement, Covered With Plaster. It Is Planned To Build An Air Conditioning System Developed In The Hvac Section. The External Bodies Of The Air Conditioners Will Be Installed On The Facade And Will Be Drained Externally. - Construction Of A Photovoltaic Installation On The Roof, Developed In The Electrical Department, Is Planned. - It Is Planned To Replace The Lighting Fixtures With Energy-Saving Ones. • Accompanying Measures: - Dismantling Of Joints And Installation Of New Drainage Pipes - Complete Plastering Of The Building From The Outside After Renovation And With Thermal Insulation. - Before Laying The Thermal Insulation On The Facades, The Compromised Plaster Is Knocked Down And Removed To The Base, And Then Restored After Spraying The Base With Cement Mortar Or Other Suitable Materials To Ensure A Strong And Level Base For The Thermal Insulation Boards. - Installation Of Drainage Profiles On The Corners And Edges Of The Building. - Installation Of An External Aluminum Window Sill Along The Entire Window Frame From The Outside, Turning The Sides With Gypsum Plaster And Plasterboard - From The Inside And Painting Twice When Installing The New Window Frame. The Photovoltaic Installation (Pvep) For Own Needs Will Be Located On The Roof Of The Building. It Is Planned To Build A Double-Armed Ramp With A Slope Of 5% And A Double-Sided Railing With A Double Handrail To Provide Access To The Entrance Of The Building From The North. The Ramp And Landing With Stairs From The North Will Be Paved With Granite Slabs With A Rough Surface, Resistant To Slipping And Freezing. Before Laying Flooring On The Steps, It Is Planned To Repair Them Where There Is A Broken Integrity.
Key Value
Tender Value
556,486 - BGN
Tender Documents
Global Tender Document
dc376bb7-1a4e-4d8d-952e-284dc81c889e.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders