GTR 78689357

Tenders Are Invited For Increasing Accessibility By Adapting Rooms To Sanitary Requirements In The Building Of The City Hall In Jasło

ICB — International Competitive Bid Closed Central Europe
Tender Information
GTR Reference
78689357
Tendering Authority
Subscribe to view
Tender No
FE.042.23.1.2024
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Increasing Accessibility By Adapting Rooms To Sanitary Requirements In The Building Of The City Hall In Jasło
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
11-04-2024 Closed
Work Detail
1. The Subject Of The Order Is To Increase Accessibility By Adapting Rooms To Sanitary Requirements In The Building Of The City Hall In Jasło, Implemented As Part Of The Project Financed By The Eea Financial Mechanism 2014-2021 And The State Budget Entitled “Jasło – My City, My Home.2. Scope Of Dismantling Works:A) Disassembly Of Doors In All Toiletsb) Dismantling Of Sanitary Equipment (Sinks, Washbasins, Urinal) And Handing Over To The Ordering Partyc) Dismantling Of Electrical Equipment And Handing Over To The Ordering Party.D) Demolition Of Partition Walls And Only Then Cutting Off The Tiles On The Walls And Floors . E) It Is Not Planned To Cut Out The Under-Plaster Electrical Installation. F) Dismantling The Above-Plaster Water And Sewage Installation With Inlet Connections With Plugs Left (Without Dismantling From Under The Plaster) And Central Heating. (Risers, Radiator Branches And Radiators) Above-Plaster And Complete Demolition Of Water Risers And Sanitary Sewage. Copper Pipes And Radiators After Dismantling To Be Handed Over To The Ordering Party.G) Removal Of Demolition Debris.1. Moving The Door Openings To Another Place With The Construction Of New Doors And Bricking Up The Openings Left After Dismantling. All Activities In This Regard Are Described In The Bill Of Quantities. In The Partition Walls, In The Lintel, Install Angles Made Of Cold-Formed Steel L 50 X 50, Properly Protected Against Corrosion. The Walls Should Be Made Of Hollow Bricks Or Aerated Concrete Shapes Of Appropriate Thickness, Making Sure To Make Cracks In The Walls At Least In Every Third Layer And With Cement Mortar (To Avoid Uncontrolled Falling Of The Bricked-Up Part). 2. After Dismantling The Floor And Wall Coverings In Each Sanitary Room, Install Liquid Foil Insulation With A Wall Flange 20 Cm Above The Planned Target Floor Level To Protect Against Possible Leaks During Installation Failure.3. After Cutting The Wall Claddings, It Will Be Necessary To Level Their Verticality, Which Should Be Done With Cement Plaster (Previously Making Grooves For The Water, Sanitary Sewage, Central Heating, Domestic Hot Water And Electrical Installations, Installing Cables And Performing Tightness Tests). The Contractor Is Responsible For The Verticality Of The Walls For The Future Stoneware Tile Cladding. 4. Reconstruction Of Subfloor Layers With Appropriate Slopes.5. Building Partition Walls From Aerated Concrete Blocks And Making Frames For Toilet Bowls, Urinals, Bidets And Approaches According To The Design. 6. In The Partition Walls Made Of Hollow Bricks On Which The Washbasins Will Be Mounted, Before Installing The Cladding, Install Handles To Prevent Them From Breaking When People Weighing More Than 100 Kg Accidentally Lean On Them.7. In The Walls Of The Toilet For Disabled People, Install Appropriate Fixtures For Handles On Which People Weighing Over 100 Kg And With An Eccentric Force Point Can Lean.8. Parameters Of Floor Tiles On The Ground Floor Of The Building:A) Grade 1B) Rectified Tilesc) Anti-Slip Class R11d) Hygienic Certificate For Public Utility Buildings) Water Absorption Eb≤0.5%F) Tiles Group Bia - Unglazedg) Flexible Grout With A Content Of Volatile Organic Compounds ≤ 3% Voc And Abrasion Resistance Cg2 According To Pn-En 13888H) Adhesion Class Of Tile Adhesives C2 According To Pn-En 12004I) Breaking Force [N] Minimum 1300 En14411:2012J) Bending Strength [N/Mm2] Minimum 35 En14411: 20129. Parameters Of Wall Tilesa) Grade 1B) Rectified Tilesc) Hygienic Certificate For Public Utility Facilitiesd) Water Absorption Eb≤0.5%E) Bia Group Of Tiles - Unglazed And Glazedf) Flexible Grout With A Content Of Volatile Organic Compounds ≤ 3% Voc And Resistance To Abrasion Cg2 According To Pn-En 13888G) Adhesion Class Of Tile Adhesives C2 According To Pn-En 12004H) Breaking Force [N] Minimum 1300 En14411:2012I) Bending Strength [N/Mm2] Minimum 35 En14411:201210. The Size Of The Tiles According To The Toilet Visualization Developed By The Ordering Party: 1197 X 597, 595 X 595, 11. Handles For The Disabled, Washbasin Faucets And Other Sanitary Equipment - Stainless Steel, Chrome.12. Washbasins, Wall-Hung Bowls, Urinals And Bidet In White, Sinks In Black. 13. Door Frames And Entrance Doors In Light Brown Or Similar Color - To Be Agreed With The Ordering Party. All Doors Must Have Door Closers And Opening Angle Limiters - Except Doors To Toilets For Disabled People.14. Entrance Door To The Toilet For Disabled People With An Extended Handle Or An Additional Opening Mechanism. Attention! The Door Must Not Have A Door Closer. 15. In The Washroom On The Ground Floor, A Foldable, Approved Baby Changing Table Should Be Installed, Located On The Wall Opposite The Entrance Wall, At A Height When Unfolded Above The Sink.16. In A Toilet For The Disabled, A Signal Must Be Installed At A Height Of 0.9 - 1.2 M To Call For Help, Located Between The Washbasin And The Toilet Bowl With A Buzzer And A Red Light Above The Door On The Corridor Side. The Indoor Siren Must Have A Switch-Off Function After Providing Assistance To The Calling Person.17. In Each Of The Renovated Rooms, One Luminaire Near The Entrance Door Must Have The Additional Function Of A Directional Luminaire Indicating The Exit To The Corridor In The Event Of A Power Outage Or Failure In The Electrical Installation (Evacuation Luminaire). All Led Lighting Fixtures In Each Room Must Be Activated By An Hf Motion Sensor (High Frequency Motion Sensors) For Their Basic Function.18. Above The Lines Of Laid Tiles And Ceiling Plasters Should Be Wiped By Removing Existing Paint Layers. After Installing Flush-Mounted Installations In The Walls And Flat Flush-Mounted Cables To The Lighting Fixtures And Grouting The Grooves, Apply Plaster And Paint With The Paint Specified In The Construction Design. 19. Lay The Tiles On The Walls According To The Visualization With A 1 Mm Thick Joint. Window And Door Slats Should Also Be Covered With Tiles According To The Visualization (Decisions Regarding Leaving The Window Sills Will Be Made During The Works). Make Any Holes For Mounting Utensils Or Accessories With Tools Of Appropriate Diameters, Which Will Be Aesthetically Covered With Discs Or Plugs. 20. The Electrical Installation Will Be Carried Out In Corrugated Installation Pipes, Flush-Mounted, With Grout Mortar. All Distribution And Accessory Installation Boxes Are Flush-Mounted With A Certificate. Electrical Equipment In The Form Of Key Switches, Plug Sockets, Etc. According To The Visualization Design. 21. Cold Water And Hot Water Installations (Temperature Up To + 70 0 C) Should Be Made Of Plastic Pipes Gripped According To Technical Specifications In A Thermal Insulation With A Jacket Wall Thickness Of 6 Mm. Grooves Should Be Grouted At Least In The Lines Where The Tiles Meet. Cover The Grooves In Other Places With Tile Adhesive. Connection From The Boiler Room To The Existing Mens Toilet On The Ground Floor. 22. Central Heating Installation Also Made Of Plastic Pipes And New Radiators According To The Visualization Design. 23. System Walls And Doors Of Sanitary Cabins Made Of 12 Mm Thick Hpl Boards With Locks In The Colors As Shown In The Visualization.24. Adaptation And Adaptation Of The Boiler Room To The Needs Of Domestic Hot Water. Described In The Appropriate Cost Estimates. 25. Electric Locks With Combination Keypads Should Be Installed In The Entrance Doors To Toilets And Scullery On The 1St Floor, 2Nd Floor And 3Rd Floor In Order To Limit Unauthorized Persons Using These Rooms. Instead Of Using A Keyboard, The Ordering Party Allows For The Installation Of An Access Card Reader. Public Toilets On The Ground Floor Are Open (The Toilet For Disabled People Is Locked From The Inside So That It Can Be Opened In An Emergency In The Event Of Calling For Help From Inside Using An Acoustic-Optical Siren). Doors With An Electronic Keyboard And Electric Locks Must Have An Emergency Opening Option In The Event Of A Power Failure Or An Individual Battery Power Supply For 2 Hours. 26. The Contractor Is Obliged To Ensure, In Accordance With Art. 100 Of The Public Procurement Law, So That The Subject Of The Order Is Implemented Taking Into Account The Needs Of All Users, Including Ensuring Accessibility For Disabled People.27. Work That Is Burdensome In Terms Of Dust And Noise Should Be Carried Out After Office Hours And On Non-Working Days In Consultation With The Ordering Party.28. Washbasin And Sink Cabinets According To Visualization. 29. Equipment With Stainless Steel Soap, Toilet Paper And Toilet Brush Dispensers. Other Equipment (Mirrors, Dryers, Etc. - According To Visualization).3. A Detailed Description Of The Subject Of The Order Can Be Found In Appendix No. 4 To The Swz - Documentation.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
63d13afc-f7a2-4aa2-8ecc-c68966665b94.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders