Tenders Are Invited For Carrying Out Periodic Technical Inspections Of Premises/Residential Buildings Used By The National Agricultural Support Center, Field Branch In Olsztyn In 2024 And 2025

Tender Detail

78688897
OLS.WOP.260.5.2024.SB
Self-Funded
Tenders Are Invited For Carrying Out Periodic Technical Inspections Of Premises/Residential Buildings Used By The National Agricultural Support Center, Field Branch In Olsztyn In 2024 And 2025
ICB
Central Europe
European Union
05-04-2024

Work Detail

1. The Subject Of The Order Is To Carry Out Periodic Technical Inspections, Respectively: Annual, Five-Yearly, Together With The Electrical And Lightning Protection Installations And Chimney Ducts (Exhaust Gas, Ventilation And Smoke) Of Premises/Buildings Used By The National Support Center For Agriculture, Field Branch In Olsztyn (Hereinafter Referred To As Kowr Ot Olsztyn ) ((Located In The Area Of Operation Of The Local Sections Of Kowr Ot Olsztyn (Hereinafter Sz): Mor g, Lidzbark Warmi ski, Bartoszyce, Korsze, Dzia dowo, Elbl g, Grabin, E k, Bystry, Kamionek And Olecko And In The Area Of Operation Of Kowr Ot Olsztyn)) In Accordance With With The Legal Provisions Of The Act Of July 7, 1994, Construction Law (Consolidated Text: Journal Of Laws Of 2023, Item 682, As Amended) (Hereinafter Referred To As Construction Law) And The Provisions Contained In The Draft Provisions Of The Contract With Annexes (Hereinafter Referred To As Ppu).2 . The Total Number Of Facilities/Premises To Be Inspected According To Annex No. 1, 1A And 3 To The Ppu In 2024 And 2025 Is: Annual And 5-Year Chimney Sweep Inspections A) Sz Bartoszyce Area - 20 20 - Coordinator Bernard Tomaszewski B) Sz Bystry Area - 19 19 - Coordinator Roman Predkoc) Sz Area Dzia dowo - 64 60 - Coordinator Jan Nawrockid) Sz Area Elbl g - 62 60 - Coordinator Maciej Zaleski E) Sz Area E k - 36 34 - Coordinator Albert Zabielski F) Sz Grabin Area - 59 59 - Coordinator Jaros aw Barczykowski G) Sz Korsze Area - 93 90 - Coordinator Daniela Zaruckah) Sz Lidzbark Warmi ski Area - 19 7 - Coordinator Antoni Wyszomirskii) Sz Mor g Area - 5 5 - Coordinator Antoni Wyszomirski J) Sz Olecko Area - 49 41 - Coordinator Aneta Kielichk) Area Olsztyn-Klewki 4 2 - Senior Specialist Zbigniew Ratajczyk L) Kamionek Area 2 0 - Coordinator Tomasz uchowski Total: 432 Premises 397 Premises And Outbuildings On The Sz Premises In The Total Number Of 113: Buildings: Olsztyn: Ul. G owackiego 6, Ul. Ba tycka 63Elbl g: Ul. Nowodworska 10Bjastarnia: Ul. Fr. Sychty 41Bartoszyce: Ul. K trzy ska 45Agas Boiler Rooms: (Annual Inspection Of The Gas Installation And Chimney Ducts: Exhaust And Ventilation) Korsze: Sz Field Office Al. Wojska Polskiego 41A Nidzica: Former Field Office Of The Armed Forces Ul. Mickiewicza 9 Mor g: Field Office Of The Armed Forces Ul. Dworcowa 13 Olsztyn: Ul. Ba tycka 63 Elbl g: Sz Field Office Ul. Nowodworska 10B Grabin: Sz Field Office Grabin 17Gi ycko: Sz Field Office Bystry 6A Jastarnia: Ul. Fr. Sychty 41Oil Boiler Rooms: (Annual Inspection Of Chimney Flues: Exhaust And Ventilation) E k: Sz Field Office Ul. Zamkowa 8 Olecko: Field Office Of The Armed Forces Ul. Os. Lesk 203. Note: The Number Of Objects/Premises During The Execution Of The Order May Change Due To Sale Or Other Form Of Permanent Disposal Of The Premises Or Disclosure.4. The Contractors Obligations Include Performance, In Accordance With Art. 62 Section 1 And Art. 62A Of The Construction Law: 1) Periodic Annual Inspection, Consisting In Checking The Technical Condition Of: A) Elements Of Buildings/Premises And Installations Exposed To Harmful Atmospheric Influences And Destructive Effects Of Factors Occurring During The Use Of The Facility, B) Installations And Devices Used For Environmental Protection, C) Gas Installations (Including The Gas Stove + Cylinder Set) And Chimney Flues (Ventilation, Exhaust, Smoke). In Rooms With A Gas Stove + Cylinder Set - Check The Presence Of A Ventilation Grille (Include In The Report).2) Periodic Five-Year Inspection Consisting In Checking The Aesthetic Condition Along With Testing The Electrical And Lightning Protection Installations In Terms Of Connections, Accessories, Protection Against Electric Shocks, Insulation Resistance Cables And Grounding Of Installations And Apparatus.3) Preparation Of A Protocol Regarding The Inspection Of Chimney Ducts (Smoke, Exhaust And Ventilation) In The Form Of An Electronic Document Using The Ict System Supporting The Central Emission Register Of Buildings, Referred To In The Act Of October 23, 2023 On Supporting Thermal Modernization And Central Registration Of Building Emission (Consolidated Text: Journal Of Laws Of 2023, Item 2496). The Scope Of Technical Inspections Of Chimneys And Chimney Ducts/Ducts Should Include: - Testing The Patency And Tightness Of Chimney Ducts/Ducts, - Testing The Chimney Draft And The Correctness Of Connections And Outlets ,- Examination Of The Technical Condition Of Chimneys In The Attic And Above The Roof (Including Chimney Caps),- Examination Of The Correctness Of Access To Carry Out The Above-Mentioned Inspection, Technical Condition Of: Hatches, Ladders And Chimney Benches.5. As Part Of The Implementation Of The Subject Of The Order, The Contractor Should Also: 1) Prepare And Submit To The Ordering Party 2 Copies Of Post-Inspection Reports, 2) During The Inspections, The Recommendations From The Previous Inspection Should Be Checked And The Ordering Party And The Sz Coordinator Should Be Informed About Any Irregularities.6. Additional Information Regarding The Execution Of The Subject Of The Order: 1) Inspection Reports Should Be Confirmed With A Hand-Signed Signature By The Tenant Of The Premises Or The Security Coordinator In The Case Of A Vacant Property And Checked By The Ordering Party. 2) A One-Time Periodic, Annual Inspection Of The Technical Condition Of The Residential Premises Should Be Carried Out In The Same Way As Possible For The Entire Facility. Construction. 3) In The Event Of A Threat To Human Life Or Health, The Report Must Be Immediately Submitted To The Ordering Party And The Sz Coordinator.7. A Detailed Description Of The Subject Of The Order Can Be Found In The Ppu And In The Annexes To The Above-Mentioned. Ppu, Which Constitute Annex No. 7 To The Swz.

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail