GTR 77274164

Tenders Are Invited For Delivery Of An Ultrasound Device For The Hospital Emergency Department

ICB — International Competitive Bid Closed Central Europe
Tender Information
GTR Reference
77274164
Tendering Authority
Subscribe to view
Tender No
Zp/18/TP/24
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Delivery Of An Ultrasound Device For The Hospital Emergency Department
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
08-03-2024 Closed
Work Detail
Ultrasound Machinel.P. Detailed Assortment Unit Of Measure Quantity Pcs. Net Value Vat Rate Gross Value Manufacturer With Catalog Number1. Ultrasound Device, Pcs. 1 Description Of The Subject Of The Orderrequirements And Technical Parameters Of An Ultrasound Device For Bedside Patient Assessment For The Needs Of Sorlp. General Data Of The Offered Device1 Manufacturer Specify 2 Name And Type Specify 3 Country Of Origin Specify 4 The Device Is Brand New, Unused, Year Of Manufacture. Min. 2023, Post-Demonstration Devices Are Excluded. Specify 5 The Device Is Delivered By The Manufacturers Authorized Representative In Poland. Specify 6 Services Covered By The Warranty Provided By The Manufacturer Or An Authorized Representative Of The Manufacturer Of The Offered Device In Poland. Specify 7. Approval Of The Device For Marketing On The Polish Market As A Medical Device. Provide No. Design And Required Parameters Of The Device. Limit Condition. Offered Value. 1. Device Dedicated To Comprehensive Bedside Assessment Of The Patients Condition In The So-Called Life-Threatening Emergencies - Point Of Care. Yes 2 A Stationary, Mobile Device With A Single-Modular Design, Transportable On Four Swivel Wheels With The Possibility Of Blocking Them And Driving Straight. Yes 3 The Device Is Made Using Fully Digital Technology, A Broadband Beam Forming System With The Possibility Of Pulse Shaping. Yes 4 Range Of Applications, Operating Frequency Min. 1Mhz-15Mhz. Yes, Specify 5 Number Of Independently Processed Transmitting And Receiving Channels Min. 19,000. Yes, Specify 6 System Dynamics Min. 165 Db. Yes, Specify 7 Maximum Permissible Weight Of The Device 75 Kg. Yes, Specify 8 Minimum 3 Independent Imaging Head Sockets. Yes 9 Lcd Monitor At Least 17 Inches With A Resolution Of At Least 1280 X 1024 Ensuring A Wide Viewing Angle With Ambient Light Compensation. Yes, Specify 10 Monitor Without Interlacing Or On A Movable, Articulated Arm With The Possibility Of Adjusting It Independently Of The Device Console In The Vertical Up/Down Plane And Horizontal Left/Right Min. 180 Degrees. Yes, Specify 11 Console, Control Panel In The Form Of A Touch Panel Without Buttons, Switches And Sliders, Made Of Durable Material, E.G. Ceramic Or Glass, Smooth, Uniform, Resistant To Spills And Bodily Dirt, Suitable For Disinfection With Liquid Agents. Tak12 Adjustment Of Raising And Lowering The Device Desk (Up/Down) Min. 25 Cm. Yes, Enter 13 Keyboard For Entering Patient Data. Yes14 Possibility Of Introducing The System In The So-Called Sleep State And Then Wake It Up Again Within A Maximum Of 5 Seconds. Yeslp. Design And Required Parameters Of The Device. Limit Condition. Offered Value15. Possibility Of Operating The Device With Power From The Factory-Built Battery Or Batteries After The Device Has Been Disconnected From The Power Supply For At Least 2 Hours. Yes, Specify 16 Power Supply From The Ac Mains With A Voltage Of 220-240V 50Hz. Yes 17 Integrated, Built-In Black And White Video Printer And Cd/Dvd Recorder. Yes 18 Image Archiving System On A Built-In Hard Drive With A Capacity Of Min. 500 Gb With The Ability To Export Data To Portable Media Such As Pendrives And Optical Discs Such As Cd-Rom/Dvd In At Least Jpeg, Bmp, Avi, Dicom 3.0 Or Equivalent Formats Compatible With Windows And The At Least Dicom 3.0 Standard. Yes, Specify 19 Possibility To Archive Sequences Of Moving And Static Images, As Well As Reports From The Conducted Examination On The Cameras Hard Drive. Yes 20 Cameras Equipped With An Image Data Exchange Port - Video Output In The Vga Standard. Yes 21 The Device Is Equipped With A Lan Network Connection With A Data Exchange Rate Of At Least 100 Mb/S. Tak22 The Device Is Equipped With A Built-In Interface Enabling Digital Imaging And Data Storage And Transmission Via Telecommunications Networks In A Medical Standard Of At Least Dicom 3.0. Tak23 Minimum Of 3 Active Usb Ports For Archiving Static And Dynamic Images On Portable Memory Such As Pendrive Or Flash. Yes, Provide24 3-Lead Ecg Cable Input (Socket) For Monitoring Patients Vital Signs. Tak25 2D Imaging Depth In The Minimum Required Range From 1 To 30 Cm. Yes, Specify 26 Image Refresh Rate (Frame Rate) In 2D Mode Min. 750 Images/Second. Yes, Specify27 Zooming Without Loss Of Image Resolution In Real Time (Zoom) Min. 5X. Yes, Specify28 Harmonic Imaging And Phase Inversion Imaging Available. Yes29 Maximum Number Of Frames (Images) Stored At One Time In Dynamic Memory (Cine Loop) In 2D And Cd Mode Min. 1000 Images. Yes, Specify30 Possibility Of Minimum Three-Zone Range Adjustment Of The Transverse Gain Of The Tgc Or Stc Beam. Tak31 Possibility To Smoothly Change The Width Of The Displayed 2D Image For All Heads Offered. Tak31 Dividing The Image Into Two And Simultaneously Displaying B+B, B+B/Cd Images In Real Time. Tak32 On-Screen Comparison Of Archived Images With Real-Time Images. Yeslp. Design And Required Parameters Of The Device Boundary Condition Offered Value33 Function That Reduces Artifacts And Adaptive Noise In 2D Imaging Such As Sri Or Equivalent. Yes, Provide 34 Complex Multidirectional Imaging Of The Examined Structures In Real Time (Sending Several Ultrasound Beams Through The Same Head Crystals At Different Angles). Yes, Specify 35 Possibility Of A Centerline Available On The Head And On The Screen In 2D Mode, Providing Visualization Of The Needle Path In Navigation Outside The Imaging Plane. Yes 36 In 2D Mode, There Is A Possibility Of Having A Grid Available In The Image That Allows You To Assess The Size And Distance To The Structure In Treatments Requiring The Introduction Of A Needle. Yes 37 Number Of Presets Programmed For Applications And Heads, The So-Called Presets Min. 30. Yes, Specify 38 Automatic Continuous 2D Image Optimization Function (Including Setting Brightness, Image Contrast And Tgc Depth Gain Compensation), Which Does Not Require Manual Activation By The User. Yes 39 Automatic Image Optimization In B-Mode Using One Button (Including Setting Brightness, Image Contrast And Tgc Depth Gain Compensation). Yes 40 Automatic Image Optimization In The Pw Doppler Mode (Including Adjustment Of The Baseline And Prf/Scale And Spectrum Gain) Available On All Heads. Tak41 Available Operating Modes: B-Mode (2D), Color Doppler (Cd), Power Doppler And Directional Power Doppler With Flow Direction Detection (Cpa), Pulsed Spectral Doppler (Pw) With High Hprf Processing Frequency, Continuous Wave Spectral Doppler (Cw) ,M-Mode, Color M-Mode,Duplex Mode (2D + Pw)Triplex Mode (2D+Cd +Pw) Tak42 Trapezoidal And Rhombus Imaging. Yes43 Maximum Measured Color Doppler (Cd) Flow Velocity Min. 500 Cm/S. Yes, Specify 44 Smooth Adjustment Of The Color Doppler Gate Tilt In The Minimum Range From -15° To +15°. Yes, Specify 45 Maximum Measured Pw Doppler Flow Velocity With Zero Angle Correction Min. 950 Cm/S. Yes, Specify 46 Adjustment Width Of The Pw Doppler Gate In The Minimum Range From 10 Mm To 29 Mm. Yes, Specify47 Pw Doppler Gate Angle Correction In The Minimum Range Of +/- 80°; Angle Correction In One-Degree Increments Throughout The Entire Range. Tak48 Velocity Range For Cw Doppler With Zero Gate Angle Correction Min. 20 M/S. Yes, Specify49 Perpendicular Positioning Of The M-Mode Lines To The Examined Anatomical Structures. Tak50 Adaptive Doppler Improving The Visibility Of Weak Signals. Tak51 Distance Measurement In 2D Mode Min. 8 Pairs Of Measurement Cursors On One Image, Measurement Of Perimeter Or Area Using The Ellipse Method, Solid Or Dashed Line Outline In 2D Mode. Yes, Specify No. Design And Required Parameters Of The Device. Limit Condition. Offered Value52. Manual Distance Measurement In The Doppler Mode (Determination Of Time And Speed). Yes 53 Automatic Calculation Package For Doppler Pw (Automatic Contouring And Determination Of The Doppler Spectrum With Analysis Of Min. Pi, Ri, S, D Parameters) In Real Time And On A Frozen Image. Tak 54 Specialized Software For Examinations Of The Abdominal Cavity And Superficial Structures, Post-Traumatic Examinations Of The Abdominal Cavity And Heart - Fast, Cardiological, Vascular And Access To Vessels, Tcd, Assessment Of Lungs And Nerves. Yes 56 Broadband Line Head With Variable Operating Frequency, Min. 3.0- 12.0 Mhz (+/- 1Mhz):- Number Of Elements Min.128,- Face Width 39 Mm, +/- 1Mm- Imaging Min. 2D, Cd/Cpa, Pw, Harmonics. Yes, Specify And Describe 57 Broadband Convex Head, Made Using Directed Crystal Polarization Technology (Min. 300 Acoustic Elements) Or Made Using Matrix Technology Min. 900 Acoustic Elements With Variable Operating Frequency In The Range Of Min. 1.0 – 6.0Mhz (+/- 1Mhz), - Head Scanning Angle Min. 70 Degrees, - Imaging Min. 2D, Cd/Cpa, Pw, Harmonics. Yes, Specify And Describe 58 Broadband Sector Head, Made Using Directed Crystal Polarization Technology (Number Of Elements: Min. 80) Or Matrix Technology (Min. 800 Elements), With Variable Operating Frequency In The Range Of Min. 1.0- 6.0 Mhz (+/- 1Mhz), - Scanning Angle Min. 90 Degrees, - Imaging Min. 2D, Cd/Cpa, Pw, Cw, Harmonics. Yes, Provide And Describe Due To The Limited Number Of Characters, Further Detailed Description Can Be Found In The Swz
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
f0e77910-c775-4afe-84b1-9b2b5b8d2115.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders